TRACEABLE AO-94460-72

Traceable® Digital Thermometer with Calibration (Bottle Probe)

Model: AO-94460-72 | Brand: TRACEABLE

вступ

This manual provides detailed instructions for the proper use, setup, and maintenance of your Traceable® Digital Thermometer with Bottle Probe. This precision instrument is designed for accurate temperature monitoring, particularly in environments requiring stable temperature readings such as refrigerators, freezers, and water baths. It features a sealed bottle probe that mimics the temperature of stored liquids, preventing false alarms from temporary door openings.

Each unit comes with a NIST-traceable certificate from an ISO/IEC 17025:2017 (1750.01) accredited calibration laboratory, ensuring accuracy and reliability.

Продукт закінченийview

Traceable Digital Thermometer with Bottle Probe

Малюнок 1: Спереду view of the Traceable Digital Thermometer with Bottle Probe. The display shows current, minimum, and maximum temperatures. The bottle probe is connected via a cable.

Traceable Digital Thermometer in a refrigerator setting

Figure 2: The Traceable Digital Thermometer with its bottle probe positioned inside a refrigerator, demonstrating its typical application for stable temperature monitoring.

The Traceable Digital Thermometer is equipped with a triple-display, allowing simultaneous viewing of the current, minimum, and maximum temperatures. The sealed bottle probe is filled with a non-toxic glycol solution, which buffers temperature changes, providing a more accurate representation of the temperature of stored contents rather than ambient air fluctuations.

Налаштування та встановлення

  1. Установка батареї: The thermometer requires one AA battery (included). Open the battery compartment on the back of the unit and insert the battery, observing polarity.
  2. Розміщення зонда:
    • Place the bottle probe inside the environment you wish to monitor (e.g., refrigerator, freezer). Ensure the probe is positioned where it will accurately reflect the temperature of the contents.
    • Route the probe cable carefully to avoid pinching or damage.
  3. Розміщення блоку:
    • Use the fold-out stand to place the unit on a flat surface.
    • Utilize the magnetic strips on the back to attach the unit to a metal surface (e.g., refrigerator door).
    • Hang the unit on a wall using the keyhole slot.
  4. Початкове ввімкнення: The unit should power on automatically once the battery is installed. The display will show the current temperature, along with the minimum and maximum recorded temperatures since the last reset.
Назад view of Traceable Digital Thermometer showing battery compartment and stand

Малюнок 3: Задня частина view of the thermometer, illustrating the battery compartment, fold-out stand, and wall-mount keyhole.

Інструкція з експлуатації

Функції відображення

The thermometer's display shows three temperature readings simultaneously:

Функції кнопок

Кнопкафункція
ПАМ'ЯТЬ ОЧИЩЕНАPress to clear the stored MIN and MAX temperature readings. The display will update with the current temperature as the new MIN/MAX.
РЕЖИМToggles between Celsius (°C) and Fahrenheit (°F) temperature units.
Вимикач увімкнення / вимкнення тривогиActivates or deactivates the audible alarm function. When activated, the alarm will sound if the temperature goes outside the set high/low alarm limits.
RESET (on back)A small button on the back of the unit (often recessed) used to perform a hard reset of the device, typically requiring a pointed object like a paperclip. This will clear all settings and memory.
LO/HI (on back)Buttons on the back of the unit used to set the low and high temperature alarm limits. Refer to the alarm setting section for details.

Setting Alarms (Optional)

The thermometer can be configured to sound an alarm if the temperature exceeds or falls below user-defined limits. The alarm setting buttons (LO and HI) are located on the back of the unit.

  1. Ensure the ALARM ON/OFF switch is in the OFF position before setting limits.
  2. Натисніть і утримуйте LO button on the back of the unit. The LO temperature will flash. Use the РЕЖИМ button on the front to adjust the desired low alarm limit. Release the LO button to set.
  3. Натисніть і утримуйте HI button on the back of the unit. The HI temperature will flash. Use the РЕЖИМ button on the front to adjust the desired high alarm limit. Release the HI button to set.
  4. Once limits are set, slide the ТРИВОГА УВІМК. / ВИМК switch to the ON position to activate the alarm.
  5. If the temperature goes outside the set range, the alarm will sound. To silence the alarm, slide the ALARM ON/OFF switch to OFF.
Close-up of thermometer buttons and back panel with alarm settings

Малюнок 4: Детально view of the thermometer's front control buttons (Memory Clear, Mode, Alarm On/Off) and the rear panel showing the LO, HI, and Reset buttons for alarm configuration.

Технічні характеристики

ОсобливістьДеталь
Номер моделіАО-94460-72
Діапазон температурвід -50 до 70°C (від -58 до 158°F)
роздільна здатність1° (Celsius/Fahrenheit)
Тип дисплеяDigital LCD, Triple-display
Тип зондаSealed Bottle Probe (glycol-filled)
Довжина кабелю зондаПриблизно 3 метрів (10 футів)
Джерело живлення1 батарейки типу АА (в комплекті)
Розміри продукту8.19 x 4.61 x 2.44 inches (20.8 x 11.7 x 6.2 cm); 8 ounces
Зовнішній матеріалпластик
ОсобливістьHigh Accuracy, NIST-Traceable Calibration
Включені компонентиDigital Thermometer Unit, Bottle Probe, 1 AA Battery, NIST-Traceable Certificate
Dimensions of the Traceable Digital Thermometer

Figure 5: Diagram showing the approximate dimensions of the thermometer unit.

Технічне обслуговування та догляд

Усунення несправностей

проблемаМожлива причинаРішення
Немає дисплея або дисплей тьмянийРозряджена або низька батарея; неправильне встановлення батареї.Replace the AA battery, ensuring correct polarity (+/-).
Неточні показанняProbe not properly placed; probe damage; unit malfunction.Ensure the bottle probe is fully immersed in the monitored environment. Check the probe cable for visible damage. If issues persist, contact customer support.
Сигналізація не звучитьAlarm switch is OFF; alarm limits not set correctly.Slide the ALARM ON/OFF switch to ON. Verify that the LO and HI alarm limits are set to the desired range.
MIN/MAX readings not clearingMEMORY CLEAR button not pressed firmly or unit malfunction.Press the MEMORY CLEAR button firmly. If it still doesn't clear, try a hard reset using the RESET button on the back.

Гарантія та підтримка

Traceable products are designed for reliability and accuracy. For warranty information or technical support, please refer to the official TRACEABLE website or contact your authorized distributor. Each product includes a NIST-traceable certificate, ensuring its accuracy at the time of purchase.

Для отримання додаткової допомоги ви можете відвідати TRACEABLE Store on Amazon або виробника webсайт.

Пов'язані документи - АО-94460-72

попередньоview Traceable 37804-10 Radio Signal Refrigerator Thermometer: User Manual and Instructions
Official user manual and instructions for the Traceable 37804-10 Radio Signal Refrigerator Thermometer. Learn about specifications, setup, operation, troubleshooting, and features for accurate temperature monitoring.
попередньоview Traceable Extra-Long Probe Waterproof Thermometer Instructions and Specifications
User manual and specifications for the Traceable Extra-Long Probe Waterproof Thermometer (Cat. No. 6406), including operation, probe use, display messages, troubleshooting, and warranty information.
попередньоview Інструкції щодо термометра для холодильника/морозильної камери TraceableLIVE WiFi Datalogging
Вичерпні інструкції з налаштування та експлуатації термометра для холодильника/морозильника TraceableLIVE WiFi Datalogger, що охоплюють елементи керування, технічні характеристики, налаштування, конфігурацію Wi-Fi, сигналізацію та усунення несправностей.
попередньоview Інструкції та характеристики термометра "Кенгуру" з можливістю відстеження
Інструкція користувача та технічні характеристики термометра «Кенгуру» Traceable, з детальним описом роботи, таких функцій, як температурні сигналізації та пам'ять, управління кабелем зонда, використання настільної стійки, заміна батареї та інформація про гарантію.
попередньоview Короткий посібник з експлуатації цифрового термометра для холодильника/морозильника з можливістю відстеження
Quick-start guide for the Traceable Refrigerator/Freezer Digital Thermometer (Models 5650, 5651, 5652). Learn setup, configuration, and alarm functions for accurate temperature monitoring.
попередньоview Короткий посібник з експлуатації цифрового термометра для холодильника/морозильника з можливістю відстеження
Короткий посібник із використання цифрового термометра для холодильника/морозильника з можливістю відстеження (моделі 5650, 5651, 5652). Дізнайтеся, як налаштувати, налаштувати сигналізацію та зрозуміти повідомлення на дисплеї для точного контролю температури.