ACiQ B0DHFF2DKL

Інструкція з експлуатації центральної інверторної системи теплового насоса ACiQ 2.5 Ton 17 SEER2

Model: B0DHFF2DKL

1. Вступ

This manual provides essential information for the installation, operation, and maintenance of your ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System. This system is designed to provide efficient heating and cooling for residential and light commercial applications. Please read this manual thoroughly before attempting any installation or operation to ensure proper function and safety.

2. Інформація про безпеку

Always prioritize safety. Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury, or death. Consult a qualified installer, service agency, or the gas supplier for information or assistance. The information contained in this manual is intended for use by qualified service personnel only.

  • Електрична безпека: Ensure the power supply is disconnected before performing any service or maintenance. All electrical wiring must comply with local and national electrical codes.
  • Поводження з холодоагентом: This system uses R-454B refrigerant. Only certified technicians should handle refrigerants.
  • Установка: Монтаж повинен виконуватися ліцензованим фахівцем з опалення, вентиляції та кондиціонування повітря.
  • Засоби індивідуального захисту: Always wear appropriate personal protective equipment (PPE) such as gloves and safety glasses during installation and maintenance.

3. Ключові характеристики

  • Інверторна технологія: Provides precise temperature control, reduced energy consumption, and quieter operation.
  • Висока ефективність: 18.8 SEER2 and 9.7 HSPF2 ratings for energy savings.
  • Широкий робочий діапазон: Reliable performance from -13°F to 122°F.
  • Тиха робота: Indoor noise levels as low as 44 dBA, outdoor unit at 60 dBA.
  • Міцні компоненти: Rotary compressor, aluminum coil, and fiberglass-free insulation.
  • Екологічно чистий холодоагент: Utilizes R-454B refrigerant.
  • Гнучка установка: Supports horizontal and vertical air handler installation.
  • Інтелектуальне керування: Compatible with wired controllers, WiFi, and third-party thermostats.
  • Integrated Back-up Heat: Includes a 10kW back-up heat kit for supplemental heating.

4. Компоненти Overview

The ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System includes the following main components:

  • Outdoor Condensing Unit (Heat Pump)
  • Блок обробки повітря в приміщенні
  • 10kW Back-up Heat Kit
  • 30' Line Set
  • Gauge Electrical Whip
  • 60A Non-Fused Disconnect Switch
  • Термостат WiFi
  • Захист від перенапруг
  • CPS Charging Adapter
  • Настінний рукав
ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System components

малюнок 1: закінченоview of the ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System, showing the outdoor unit, indoor air handler, 10kW back-up heat kit, thermostat, line set, and various installation accessories.

5. Налаштування та встановлення

Installation of this ACiQ heat pump system requires specialized knowledge and tools. It must be performed by a qualified and licensed HVAC technician to ensure safety, compliance with local codes, and optimal performance. Refer to the detailed installation manual provided with the product for specific instructions.

5.1 Перевірки перед інсталяцією

  • Verify that the electrical supply matches the unit's requirements (Indoor: 115/208/230V, 60Hz, 1Ph; Outdoor: 208/230V, 60Hz, 1Ph).
  • Ensure adequate space for both indoor and outdoor units, allowing for proper airflow and maintenance access.
  • Confirm that the maximum piping length (164 ft / 50m) and height difference (82 ft / 25m) are not exceeded.

5.2 Air Handler Installation

The indoor air handler unit is designed for flexible installation, supporting upflow, downflow, and horizontal configurations to suit various space requirements.

Multi-Positional Air Handler Unit installation options

малюнок 2: Diagram illustrating the multi-positional capabilities of the indoor air handler unit, showing options for upflow, downflow, and horizontal installation.

5.3 Розміщення зовнішнього блоку

Consider the outdoor unit's dimensions and required clearances for optimal performance and maintenance. The unit features a compact design compared to traditional systems.

Outdoor unit size comparison with traditional units

малюнок 3: Graphic comparing the smaller footprint of the ACiQ outdoor unit (20 inches clearance) versus a traditional unit (36 inches clearance), highlighting its high efficiency and self-cleaning features.

6. Інструкція з експлуатації

Your ACiQ heat pump system offers advanced control options for comfortable and efficient operation.

6.1 Основні режими роботи

  • Режим охолодження: Provides cooling with a capacity of 31,000 BTU/hr. Operates efficiently from -13°F to 122°F ambient temperatures.
  • Режим нагріву: Provides heating with a capacity of 30,000 BTU/hr at 47°F. Reliable warmth down to -13°F. The 10kW back-up heat kit provides supplemental heat when needed.
  • Режим вентилятора: Циркулює повітря без нагрівання чи охолодження.
  • Автоматичний режим: Автоматично перемикається між обігрівом та охолодженням для підтримки встановленої температури.
ACiQ outdoor unit operating in extreme heat

малюнок 4: The ACiQ outdoor unit installed on a patio, demonstrating its ability to operate effectively in extreme heat conditions, up to 122°F.

ACiQ outdoor unit operating in extreme cold

малюнок 5: The ACiQ outdoor unit partially covered in snow, illustrating its capability to operate in extreme cold temperatures, down to -13°F.

6.2 Інтелектуальне керування

The system can be controlled via the included wired thermostat, WiFi-enabled app, or compatible third-party thermostats. The WiFi app allows for remote control and monitoring of your system.

ACiQ Smart Home app and wired thermostat

малюнок 6: Image showing the ACiQ Smart Home mobile application interface on a smartphone alongside a wired thermostat, demonstrating the system's smart control capabilities for climate management.

7. Технічне обслуговування

Regular maintenance ensures the longevity and efficiency of your ACiQ heat pump system. Always disconnect power before performing any maintenance.

  • Заміна повітряного фільтра: Check and replace air filters in the indoor air handler every 1-3 months, or more frequently if needed. Dirty filters restrict airflow and reduce efficiency.
  • Очищення зовнішнього блоку: Keep the outdoor unit free from debris, leaves, and dirt. Periodically clean the coils with a soft brush or water hose (ensure power is off).
  • Дренажна система: Ensure the condensate drain line is clear and free of blockages to prevent water overflow.
  • Професійна перевірка: Schedule annual inspections and maintenance by a qualified HVAC technician.

8. Вирішення проблем

This section provides solutions for common issues. For complex problems, contact a qualified HVAC technician.

  • Немає живлення: Check circuit breakers and ensure the disconnect switch is in the ON position.
  • Недостатнє нагрівання/охолодження: Verify thermostat settings, check air filters for blockage, and ensure outdoor unit is not obstructed.
  • Незвичайні шуми: Minor operational noises are normal. Loud or unusual noises may indicate a problem requiring professional inspection.
  • Витоки води: Check condensate drain line for blockages.

9. Технічні характеристики

Dimensions of ACiQ indoor and outdoor units

малюнок 7: Image displaying the dimensions of both the indoor air handler unit (49.02" H x 21.02" W x 21.02" D) and the outdoor condensing unit (35.04" H x 37.24" W x 16.14" D).

Діаграма холодопродуктивності теплового насоса ACiQ

малюнок 8: Chart detailing the cooling capacity of the ACiQ system at various outdoor temperatures: 86°F (118% capacity), 95°F (113% capacity), 110°F (99% capacity), and 122°F (48% capacity).

Діаграма теплопродуктивності теплового насоса ACiQ

малюнок 9: Chart detailing the heating capacity of the ACiQ system at various outdoor temperatures: -22°F (N/A), -13°F (41% capacity), 0°F (57% capacity), 17°F (70% capacity), and 32°F (73% capacity).

ОсобливістьДеталь
Потужність охолодження31,000 XNUMX BTU/год
Теплова потужність30,000 BTU/hr (at 47°F)
Рейтинг SEER218.8
Рейтинг HSPF29.7
Тип холодоагентуР-454Б
Джерело живлення внутрішнього блоку115/208/230V, 60Hz, 1Ph
Блок живлення зовнішнього блоку208/230 В, 60 Гц, 1 фаза
Максимальна довжина трубопроводу164 футів (50 м)
Max Height Difference82 футів (25 м)
Indoor Unit Dimensions (W × D × H)21.02 см × 21.02 см × 49.02 см
Outdoor Unit Dimensions (W × D × H)37.24 см × 16.14 см × 31.89 см
Вага нетто внутрішнього блоку128.97 фунтів
Вага нетто зовнішнього блоку164.02 фунтів

10. Гарантія та підтримка

ACiQ offers a comprehensive warranty for this heat pump system:

  • Гарантія на запчастини: 7 роки
  • Гарантія на компресор: 12 роки

These warranty terms are valid when the system is installed by a certified technician and registered online with the manufacturer. For technical support, service inquiries, or warranty claims, please refer to the contact information provided in your product packaging or visit the official ACiQ webсайт.

Пов'язані документи - B0DHFF2DKL

попередньоview Стандартні однозонні системи опалення ACiQ 9K-24K: інструкція з встановлення та експлуатації
Посібник з встановлення та експлуатації стандартних однозонних систем опалення ACiQ 9K-24K. У цьому посібнику детально описано встановлення, експлуатацію, безпеку та технічне обслуговування кондиціонерів ACiQ, включаючи характеристики моделі та інформацію про холодоагент R454B.
попередньоview Керівництво з встановлення центральних інверторних систем ACiQ
Вичерпний посібник з встановлення центральних інверторних систем кондиціонування повітря та теплових насосів ACiQ, що містить детальні заходи безпеки, трубопроводи холодоагенту, встановлення зовнішнього блоку, проводку, характеристики живлення, відкачування повітря та процедури тестового запуску.
попередньоview Інструкція з встановлення та експлуатації настінного повітрообладнання ACiQ та однозонного конденсаторного блоку Extreme Heat
Цей посібник містить детальні інструкції з встановлення, експлуатації та безпеки для настінних повітрооброблювачів ACiQ та однозонних конденсаторних установок для екстремальних температур, що охоплюють моделі від ACIQ-06W-HH-MD до ACIQ-24ZPL-HP230C.
попередньоview Інструкція з встановлення зовнішнього блоку центральної інверторної системи ACiQ
Вичерпний посібник з встановлення зовнішніх блоків центральних інверторних систем ACiQ, що охоплює запобіжні заходи, трубопроводи холодоагенту, проводку, встановлення блоку та процедури тестування для таких моделей, як ACiQ-18-AC, ACiQ-24-AC, ACiQ-18-EHPB та інших.
попередньоview Система теплового насоса ACiQ Next Gen з канальними трубами: короткий посібник з підключення термостата
Цей посібник містить важливу інформацію щодо підключення та проводки термостатів до системи теплових насосів ACiQ Next Gen Ducted. У ньому детально описано рекомендовані та альтернативні варіанти підключення, включаючи налаштування DIP-перемикачів та конфігурації клемних колодок для різних типів термостатів.
попередньоview ACiQ Essentials Mini-Split Air Handler & Condenser Installation and Owner's Manual
Comprehensive installation and owner's manual for ACiQ Essentials Mini-Split Air Handler and Condenser systems, covering safety precautions, parts identification, remote control operation, installation procedures, test runs, maintenance, and troubleshooting for various models. The manual also includes critical information regarding the servicing of systems using flammable refrigerant R454B, emphasizing safety protocols and regulatory compliance. It is designed for professional installers and end-users to ensure safe and efficient operation of ACiQ mini-split heat pump systems.