The MSR Guardian Gravity Water Purifier is a state-of-the-art, high-volume gravity-fed system designed for backcountry use, global travel, and emergency preparedness. It utilizes advanced hollow-fiber technology to remove viruses, bacteria, protozoa, sediment, and microplastics from challenging water sources. An integrated activated carbon stage further reduces chemicals, unpleasant tastes, and odors, providing clean and better-tasting water.

This system includes a two-stage purifier, a 10-liter dirty water reservoir, a universal bottle adapter, hoses, and a zippered carry case. It boasts a lifetime capacity of up to 3000 liters and can purify up to 1 liter of water in 2 minutes under optimal conditions.

MSR Guardian Gravity Water Purifier components laid out

Image: The MSR Guardian Gravity Water Purifier system, showing the 10-liter dirty water bag, the purification cartridge, and connecting hoses, along with the universal bottle adapter.

Інструкції з налаштування

  1. Розпакуйте компоненти: Carefully remove all components from the zippered carry case: the 10-liter dirty water reservoir, the purification cartridge, hoses, and the universal bottle adapter.
  2. Підключіть шланги: Attach the longer hose to the "dirty water" inlet on the purification cartridge (usually marked with an arrow pointing towards the filter). Attach the shorter hose to the "clean water" outlet (arrow pointing away from the filter). Ensure all connections are secure.
  3. Fill Dirty Water Reservoir: Open the top of the 10-liter dirty water reservoir and fill it with untreated water from your source. Ensure the top is securely rolled down and clipped to prevent leaks.
  4. Attach Reservoir to Filter: Connect the dirty water hose from the purification cartridge to the outlet on the bottom of the dirty water reservoir.
  5. Position for Gravity Flow: Hang the filled dirty water reservoir at least 6 feet (approximately 1.8 meters) above your clean water collection container. This height is crucial for optimal flow rate.
  6. Prepare Clean Water Collection: Place your clean water bottle, hydration reservoir, or other container below the purification cartridge's clean water outlet. The universal bottle adapter can be used to directly connect to various bottle types.
People using the MSR Guardian Gravity Water Purifier in an outdoor setting

Image: Individuals setting up and using the MSR Guardian Gravity Water Purifier, demonstrating the hanging of the dirty water bag and collection of purified water into a bottle.

Інструкція з експлуатації

Once the system is set up, the MSR Guardian Gravity Purifier operates by gravity. No pumping is required.

  1. Initiate Flow: Ensure the clean water outlet hose is positioned into your collection container. Open any clamps or valves on the clean water hose to allow water to begin flowing through the purification cartridge.
  2. Monitor Flow Rate: Water will flow from the dirty water reservoir, through the filter, and into your clean container. The system is designed for a fast flow rate, purifying up to 1 liter in 2 minutes under ideal conditions.
  3. Функція очищення: If the flow rate decreases significantly, the system features a dedicated purge hose to restore flow. Locate the purge hose (often a small, separate tube or valve on the filter). Open the purge valve or unclamp the purge hose to allow a small amount of dirty water to flush out contaminants from the filter. Close the purge valve/clamp once flow is restored. This should be done periodically, especially after filtering heavily turbid water.
  4. Заправка: When the dirty water reservoir is empty, close the clean water outlet valve, detach the reservoir, and refill it with untreated water as needed.
Diagram illustrating the hollow fiber membrane filtration process

Image: A diagram showing how the advanced hollow fiber membrane physically traps contaminants, including viruses, protozoa, and bacteria, ensuring ultimate viral protection.

Diagram showing the activated carbon component of the filter

Image: An illustration of the filter's two-stage purification, highlighting the advanced hollow fiber membrane for viral protection and activated carbon for reducing chemicals, unpleasant tastes, and odors.

Технічне обслуговування

Proper maintenance ensures the longevity and effectiveness of your MSR Guardian Gravity Purifier.

Усунення несправностей

проблемаМожлива причинаРішення
Повільний або відсутній потік води
  • Засмічений фільтрувальний картридж
  • Insufficient hanging height
  • Шлюз в системі
  • Kinked or blocked hoses
  • Perform a filter purge using the dedicated purge hose.
  • Ensure the dirty water reservoir is hung at least 6 feet above the collection point.
  • Check all hoses for kinks or blockages.
  • Ensure the dirty water reservoir is not completely sealed if it's causing an airlock (some users report needing a partial seal).
Витік води з з'єднань
  • Ослаблені з'єднання шлангів
  • Пошкоджені кільця ущільнювачів або ущільнення
  • Damage to the dirty water reservoir
  • Щільно затягніть усі з'єднання шлангів.
  • Перевірте кільця ущільнювачів та ущільнення на наявність пошкоджень; за потреби замініть.
  • Inspect the dirty water reservoir for punctures or tears.
Unpleasant Taste/Odor in Purified Water
  • Activated carbon is exhausted
  • Contamination of clean water components
  • The activated carbon component has a limited life; consider replacing the filter cartridge if taste/odor persists after extensive use.
  • Ensure all clean water collection containers and hoses are clean.

Технічні характеристики

Dimensions of the MSR Guardian Gravity Purifier carry case

Image: The zippered carry case with dimensions of 12.5 inches in length and 4 inches in width, indicating its compact size for transport.

Гарантія та підтримка

The MSR Guardian Gravity Purifier comes with a Обмежена довічна гарантія from Cascade Designs Inc. This warranty covers manufacturing defects in materials and workmanship for the reasonable lifetime of the product.

For warranty claims, technical support, or further inquiries, please contact MSR customer service. Refer to the official MSR website or the original product packaging for the most current contact information and detailed warranty terms.

Офіційний документ з інструкцією із застосування (IFU) у форматі PDF доступний для завантаження: MSR Guardian Gravity Purifier IFU (PDF).

Пов'язані документи - Охоронець гравітаційного охоронця

попередньоview MSR Guardian Purifier: Instruction Manual and Maintenance Guide
Comprehensive guide for the MSR Guardian Purifier, covering operation, maintenance, troubleshooting, specifications, and warranty information for reliable water purification.
попередньоview Гравітаційний очищувач MSR Guardian: повна інструкція з експлуатації
Детальний посібник з використання гравітаційного очищувача MSR Guardian, що охоплює налаштування, очищення, зберігання, дезінфекцію та перевірку цілісності для забезпечення безпечної питної води у відкритому середовищі.
попередньоview Функціональність SD-карти MSR: Посібник користувача для реєстраторів даних
У цьому посібнику пояснюється, як використовувати функцію SD-карти з реєстраторами даних MSR, охоплюючи запис, підготовку, зчитування, видалення даних та обсяг пам'яті.
попередньоview MSR Home Emergency Water Filter Thru-Link™ Microfilter User Manual
Comprehensive instructions for using, maintaining, and safety checking the MSR Home Emergency Water Filter with Thru-Link™ Microfilter technology. Learn how to filter water, disinfect, and store your filter for outdoor and emergency use.
попередньоview Короткий посібник з експлуатації та встановлення програмного забезпечення реєстратора даних MSR160
Дізнайтеся, як швидко налаштувати та використовувати реєстратор даних MSR160, включаючи встановлення програмного забезпечення MSR для ПК, підключення до ПК, початок запису даних та передачу даних з використанням SD-карти (опціонально).
попередньоview MSR 85 Quick Start Guide: Ultra-Low Temperature Data Logger Setup and Operation
Concise guide for setting up, configuring, and using the MSR 85 reusable PDF data logger for ultra-low temperature monitoring down to -85 °C. Includes connection, data logging, and report generation instructions.