GEYA GRD9L-R-AC220V+A-SI RCCB 2P-63A-30mA

GEYA GRD9L-R Automatic Reclosing Device User Manual

Model: GRD9L-R-AC220V+A-SI RCCB 2P-63A-30mA

1. Продукт закінчивсяview

The GEYA GRD9L-R Automatic Reclosing Device is an electromagnetic leakage circuit breaker (RCCB) designed to enhance electrical system reliability and reduce manual intervention. It automatically recloses the circuit when a leakage fault causes the RCD to trip unexpectedly, minimizing downtime and maintenance costs.

This device is suitable for various applications, including electrical network terminal lines, meter boxes, new energy circuit management, solar PV control boxes, smart electricity systems, smart homes, and charging stations for new energy vehicles.

Ключові характеристики:

  • Automatic reclosing function after RCD trip, eliminating the need for manual reset.
  • Integrated 3 reclosing attempts. An auxiliary contact can send an alarm if continuous tripping occurs within 15 minutes.
  • Manual/Automatic selector switch for operational flexibility.
  • Features double mechanical/electronic locking for enhanced safety.
  • Compatible with auxiliary contacts, alarm contacts, shunt releases, and undervoltage releases.
  • Reclosing attempt counter resets if no trip occurs or after a manual reset within 15 minutes of successful reclosure.
GEYA GRD9L-R Automatic Reclosing Device

Малюнок 1: Спереду view of the GEYA GRD9L-R Automatic Reclosing Device.

2. Інформація про безпеку

УВАГА: Installation and maintenance of this device must be performed by a qualified electrician in accordance with all local and national electrical codes and regulations. Failure to do so may result in electric shock, fire, or other serious injury.

  • Завжди відключайте живлення перед встановленням, обслуговуванням або демонтажем пристрою.
  • Забезпечте належне заземлення електричної системи.
  • Не використовуйте пристрій, якщо він виглядає пошкодженим.
  • Verify correct wiring connections to prevent malfunction or damage.
  • Пристрій розроблений для певного об'ємуtagе та номінальні струми. Не перевищуйте ці обмеження.

3. Компоненти та схеми продукту

3.1 Опис функції

Function Description Diagram

Figure 2: Diagram illustrating the automatic reclosing logic and function description. The device attempts to reclose the circuit up to three times with specific time intervals. If the interval between two successful closings exceeds 15 minutes, the program clears the accumulated closing times.

3.2 Functions Diagram (Auto Mode Logic)

Functions Diagram Auto Mode

Figure 3: Detailed flow chart of the automatic reclosing sequence. After a trip, the device attempts to reclose. If successful, it waits. If it trips again, it attempts a second reclose after 10 seconds. A third attempt follows after 60 seconds if the second fails. If all three attempts fail within 15 minutes, the device locks out and sends an auxiliary alarm. The power delay (Tr) is 2 seconds. Note: Customization of closing times and delay times requires contacting the manufacturer.

3.3 Функція блокування

Locking Function Diagram

Figure 4: Illustration of the locking mechanism. When the locking function is activated (e.g., by inserting a padlock with a diameter less than 3.5 mm), the RCCB cannot be closed, ensuring safety during circuit checks or maintenance. This prevents accidental reclosure.

4. Налаштування та встановлення

The GEYA GRD9L-R device is designed for DIN rail mounting and can be integrated with other electrical components such as an RCCB and auxiliary modules.

4.1 Інтеграція компонентів

Component Integration Diagram

Малюнок 5: Впрample of how the GRD9L-R device can be installed alongside an Auxiliary module and an RCCB on a standard DIN rail. Ensure proper alignment and secure fastening of all components.

4.2 Схема підключення

Схема підключення напрample

Малюнок 6: Прample application wiring diagram. This diagram shows the connection of the GRD9L-R device with an alarm lamp, an RCCB, and multiple load circuits. Red lines indicate live connections, blue lines indicate neutral connections. The auxiliary contacts (A1, A2, COM, NO) are used for external signaling, such as an alarm lamp. Always consult a qualified electrician for correct wiring specific to your installation.

4.3 Етапи встановлення (загальні рекомендації):

  1. Відключення живлення: Перед початком встановлення переконайтеся, що основне джерело живлення кола повністю відключено.
  2. Монтаж: Mount the GRD9L-R device, the associated RCCB, and any auxiliary modules onto a standard DIN rail within an appropriate electrical enclosure.
  3. Електропроводка: Connect the input and output terminals of the GRD9L-R and RCCB according to the wiring diagram (Figure 6) and local electrical codes. Pay close attention to live (L) and neutral (N) connections.
  4. Допоміжні з'єднання: If using, connect auxiliary contacts (A1, A2, COM, NO) for remote signaling or control, such as an alarm lamp.
  5. Перевірка: Double-check all wiring connections for tightness and correctness.
  6. Відновлення живлення: Після завершення та перевірки встановлення відновіть живлення кола.

5. Інструкція з експлуатації

5.1 Manual/Automatic Selector

The device features a selector switch labeled "AUTO" and "MANU" (Manual). This switch allows you to choose the operating mode:

  • Автоматичний режим: In this mode, the device will automatically attempt to reclose the associated RCCB after a trip, following the reclosing logic described in Figure 3. This is the default and recommended mode for continuous operation.
  • Режим MANU: In this mode, the automatic reclosing function is disabled. If the RCCB trips, it must be manually reset. This mode is useful for maintenance or specific operational requirements where automatic reclosure is not desired.

5.2 Reclosing Logic (Auto Mode)

When in AUTO mode, the device follows a specific sequence of reclosing attempts:

  1. 1st Trip: If the RCD trips, the device waits for 10 seconds, then attempts to reclose.
  2. 2nd Trip: If the RCD trips again within 15 minutes of the first reclosure, the device waits for 60 seconds, then attempts a second reclosure.
  3. 3rd Trip: If the RCD trips a third time within 15 minutes of the second reclosure, the device waits for 300 seconds (5 minutes), then attempts a third reclosure.
  4. Блокування: If the RCD trips a fourth time within 15 minutes, or if any of the three reclosing attempts fail, the device enters a lockout state. It will not attempt further reclosures automatically and will activate the auxiliary alarm contact (if connected). Manual intervention is required to reset the device.
  5. Resetting Closing Times: If no trip occurs for 15 minutes after a successful reclosure, or if the device is manually reset, the reclosing attempt counter is cleared.

5.3 Кнопка тестування

The associated RCCB typically has a test button. Pressing this button simulates a leakage fault and should cause the RCCB to trip. This is used to verify the proper functioning of the RCCB and, in AUTO mode, the reclosing device.

6. Технічне обслуговування

The GEYA GRD9L-R Automatic Reclosing Device is designed for minimal maintenance. However, regular checks are recommended to ensure optimal performance and safety.

  • Візуальний огляд: Періодично перевіряйте пристрій на наявність будь-яких ознак фізичних пошкоджень, зміни кольору або нещільних з’єднань.
  • Перевірка функціональності: Regularly test the associated RCCB using its test button. Observe if the GRD9L-R device initiates its reclosing sequence in AUTO mode.
  • Прибирання: Ensure the device is kept clean and free from dust and debris. Use a dry, soft cloth for cleaning. Do not use liquid cleaners.
  • Професійна перевірка: It is recommended to have the electrical system, including this device, inspected by a qualified electrician at least once a year.

7. Вирішення проблем

If the GEYA GRD9L-R device is not functioning as expected, consider the following:

проблемаМожлива причинаРішення
Device does not reclose automatically.
  • Device is in MANU mode.
  • Device is in lockout state after multiple failed reclosures.
  • Persistent fault in the circuit.
  • Locking function is activated.
  • Switch to AUTO mode.
  • Manually reset the device and investigate the cause of repeated trips.
  • Identify and rectify the electrical fault.
  • Ensure no padlock is inserted in the locking mechanism.
Alarm contact is continuously active.
  • Device is in lockout state.
  • Auxiliary contact wiring issue.
  • Investigate and clear the fault, then manually reset the device.
  • Check wiring of auxiliary contacts.
RCCB trips immediately after reclosure.
  • Persistent or severe electrical fault (e.g., short circuit, ground fault).
  • Immediately disconnect power and have a qualified electrician diagnose and repair the fault. Do not attempt further reclosures until the fault is resolved.

If the problem persists after attempting these solutions, contact a qualified electrician or GEYA customer support.

8. Технічні характеристики

ОсобливістьДеталь
Номер моделіGRD9L-R-AC220V+A-SI RCCB 2P-63A-30mA
БрендГЕЯ
томtage220 Вольт змінного струму
Номінальний струм63 A (as per model number)
Кількість поляків2
Тип вимикачаУЗО (пристрій захисного відключення)
Тип монтажуWall Mount, Flush Mount (DIN Rail compatible)
Розміри упаковки12 х 11.6 х 9.1 см
Вага товару350 грами
ВиробникZHEJIANG GEYA ELECTRICAL CO.,LTD

9. Гарантія та підтримка

Specific warranty information for the GEYA GRD9L-R Automatic Reclosing Device is not available in the provided product details. Please refer to the product packaging or contact GEYA customer support for detailed warranty terms and conditions.

For technical support, inquiries, or assistance with installation and troubleshooting, please contact GEYA directly through their official channels or the retailer from whom the product was purchased.

Пов'язані документи - GRD9L-R-AC220V+A-SI RCCB 2P-63A-30mA

попередньоview Каталог електрообладнання GEYA - автоматичні вимикачі, контактори та інше
Повний каталог електротехнічної продукції GEYA, включаючи мініатюрні автоматичні вимикачі, контактори, перемикачі та інше обладнання безпеки, з детальним описом специфікацій, застосувань та стандартів відповідності.
попередньоview GEYA GRD9L-W Автоматичний вимикач/ПЗВ/ПЗВ з керуванням WiFi: Інструкція з експлуатації та технічний посібник
Вичерпна інструкція з експлуатації та технічний посібник для автоматичного вимикача/захисного вимикача/автоматично-виключателя GEYA GRD9L-W з керуванням через WiFi. Охоплює застосування, функції, технічні характеристики, встановлення, роботу в мережі, усунення несправностей та деталі розмірів інтелектуальних електричних систем.
попередньоview GEYA GRD9L-W Автоматичний вимикач/ПЗВ/ПЗВ з керуванням WiFi: Інструкція з експлуатації та технічний посібник
Детальна інструкція з експлуатації автоматичного вимикача/захисного вимикача/автоматичного вимикача GEYA GRD9L-W з керуванням через WiFi. Охоплює застосування в інтелектуальних системах управління електроенергією вдома та фотоелектричних системах, функціональні характеристики, технічні параметри, схеми панелей та підключення, встановлення, налаштування мережі за допомогою застосунку Tuya Smart, поширені несправності та розміри. Важливий посібник для безпечного та ефективного керування електроенергією.
попередньоview GEYA Miniature Circuit Breakers, Contactors, and Transfer Switches Catalog | Technical Specifications
Comprehensive catalog from GEYA detailing Miniature Circuit Breakers (MCB), Residual Current Circuit Breakers (RCCB), Residual Current Circuit Breakers with Overcurrent Protection (RCBO), Molded Case Circuit Breakers (MCCB), AC Contactors, Automatic Transfer Switches, and Intelligent Circuit Breakers. Includes technical specifications, scope of application, product features, and compliance information for various models, serving industrial, commercial, and residential applications.
попередньоview Інтелектуальний мініатюрний автоматичний вимикач GEYA серії WiFi - Інструкція з експлуатації
Детальна інструкція з експлуатації та поширені запитання щодо інтелектуального мініатюрного автоматичного вимикача GEYA серії WiFi (серія ZJSB9). Дізнайтеся про встановлення, налаштування, усунення несправностей, безпеку та застосування для захисту електромережі розумного будинку.
попередньоview GEYA GPS8-10 Voltage/Current Protector Instruction Manual
Instruction manual for the GEYA GPS8-10 Voltage/Current Protector, detailing its applications, features, technical parameters, wiring, panel diagram, parameter settings, factory settings, and functional diagrams.