GENMAX GM-PUMP

GENMAX 12V DC Electric Fuel Pump GMEFP Instruction Manual

Model: GM-PUMP

1. Вступ

The GENMAX GMEFP is a 12V DC electric fuel pump designed to automatically transfer gasoline from an external fuel tank to your GENMAX small inverter generator. This system ensures continuous operation of your generator without manual refueling, enhancing convenience and efficiency.

This manual provides essential information for the safe and effective installation, operation, and maintenance of your GENMAX GMEFP fuel pump. Please read it thoroughly before use and retain it for future reference.

GENMAX GMEFP Electric Fuel Pump
Image 1.1: The GENMAX GMEFP 12V DC Electric Fuel Pump, designed for automatic fuel transfer.

2. Інформація про безпеку

WARNING: Gasoline is highly flammable and its vapors are explosive. Always handle fuel with extreme caution.

3. Особливості продукту

4. Вміст упаковки

Перевірте, чи всі перелічені нижче предмети входять до вашої упаковки:

GENMAX GMEFP Fuel Pump and Accessories
Image 4.1: The GENMAX GMEFP fuel pump shown with its included accessories: 12V DC power plugs (crocodile clips and cigarette lighter type) and a fuel hose with a primer bulb. These components facilitate connection to various power sources and external fuel tanks.

5. Налаштування та встановлення

Proper installation is crucial for the safe and efficient operation of the fuel pump. Follow these steps carefully:

5.1 Перевірка перед встановленням

GENMAX GMEFP Fuel Pump Dimensions and Thread Size
Image 5.1: Detailed dimensions of the GENMAX GMEFP fuel pump, including thread size (1.95 inches diameter, 0.18 inches pitch) and overall height (7.3 inches), crucial for compatibility with external fuel tanks.

5.2 Connecting the Fuel Pump

  1. Install the Fuel Pump: Securely screw the GENMAX GMEFP fuel pump into the fuel tank opening of your generator. Ensure a tight seal to prevent leaks.
  2. Connect Fuel Hose to External Tank: Connect one end of the provided fuel hose (with the primer bulb) to the outflow port of your external fuel tank. Ensure this connection is secure.
  3. Connect Fuel Hose to Pump: Connect the other end of the fuel hose to the tubing connection port on the GENMAX GMEFP fuel pump. This port indicates fuel flow to the generator.
  4. Підключіть живлення: Choose the appropriate 12V DC power plug (crocodile clips or cigarette lighter) and connect it to the 12V DC power cable of the fuel pump. Then, connect the power plug to your generator's 12V DC output or another suitable 12V DC power source.
  5. Позиціонування: Place the external fuel tank on a stable surface, ensuring it is below the generator's fuel tank for optimal gravity feed assistance during priming. Ensure the fuel hose is not kinked and is clear of hot engine components, especially the muffler.
GENMAX GMEFP Fuel Pump Connection Diagram
Image 5.2: Diagram illustrating the connection of the GENMAX GMEFP fuel pump to a generator and an external fuel tank. It shows the 12V DC power cable connection and the fuel hose routing, emphasizing to keep the hose away from the muffler.
GENMAX GMEFP Fuel Pump in operation with generator
Image 5.3: The GENMAX GMEFP fuel pump installed on a GENMAX generator, connected to an external red fuel tank. This setup demonstrates the automatic fuel replenishment system in use.

6. Інструкція з експлуатації

Once the fuel pump is correctly installed and connected, follow these steps for operation:

  1. Заправити паливну систему: Before starting the generator, use the primer bulb on the fuel hose to manually draw gasoline from the external tank towards the pump. Squeeze the bulb until it feels firm, indicating fuel has reached the pump.
  2. Запустіть генератор: Start your GENMAX inverter generator according to its own instruction manual.
  3. Activate the Fuel Pump: Locate the switch on the GENMAX GMEFP fuel pump and turn it to the "ON" position. The pump will begin to monitor the fuel level in the generator's tank.
  4. Automatic Refueling: When the generator's fuel level drops to a predetermined low point, the GMEFP pump will automatically activate and transfer fuel from the external tank to the generator's tank.
  5. Overfill Protection: The pump's internal fault detection system will automatically stop the fuel transfer once the generator's tank is full, preventing overfilling and ensuring safe operation.
  6. Безперервна робота: The pump will cycle on and off as needed to maintain the fuel level, allowing for extended, unattended generator operation.

Примітка: If the generator is not a GENMAX model, ensure its fuel tank depth and fuel cap thread are compatible with the pump before use.

7. Технічне обслуговування

Regular maintenance ensures the longevity and reliable performance of your GENMAX GMEFP fuel pump.

8. Вирішення проблем

If you encounter issues with your GENMAX GMEFP fuel pump, refer to the following common troubleshooting steps:

If these steps do not resolve the issue, please contact GENMAX customer support for assistance.

9. Технічні характеристики

СпецифікаціяДеталь
МодельGM-PUMP
БрендGENMAX
Джерело живлення12 В постійного струму
Режим роботиАвтоматичний
Тип газуБензин
Матеріал корпусупластик
Вага товару3.65 фунта (1.66 кілограма)
Тип монтажуКріплення бака
Applicable Generator Power2kW to 5kW (GENMAX inverter generators)
Compatible External Tank Capacity5-17 Gallons (tank not included)
Required Tank Port Depth> 3.74 дюймів
Required Tank Port Diameter2.17 дюймів
Required Tank Port Thread Pitch~ 0.18 inches

10. Гарантія та підтримка

The GENMAX GMEFP fuel pump comes with a Гарантія 1 рік з дати покупки.

GENMAX also provides FREE lifetime technical support from experienced experts. If you have any questions, require assistance with installation, operation, or troubleshooting, please do not hesitate to contact GENMAX customer support.

For warranty claims or technical support, please refer to the contact information provided on the GENMAX official webсайт або матеріали для реєстрації вашого продукту.

Пов'язані документи - GM-PUMP

попередньоview Інструкція користувача трипаливного інверторного генератора Genmax GM17000iETC
Вичерпний посібник користувача для трипаливного інверторного генератора Genmax GM17000iETC, що охоплює експлуатацію, безпеку, технічне обслуговування, усунення несправностей та технічні характеристики. Дізнайтеся, як безпечно експлуатувати та обслуговувати генератор, який працює на бензині, зрідженому нафтовому газі (LPG) та природному газі.
попередньоview GENMAX GM17000iETC Tri-Fuel Inverter Generator User's Manual
Comprehensive user manual for the GENMAX GM17000iETC Tri-Fuel Inverter Generator, covering safety, operation, maintenance, troubleshooting, and technical specifications. Learn how to safely operate and maintain your generator for gasoline, LPG, and natural gas.
попередньоview GENMAX GM12000E/GM12000ED Portable Generator User Manual
Comprehensive user manual for GENMAX GM12000E and GM12000ED portable gasoline generators, covering operation, safety, maintenance, troubleshooting, and technical specifications. Includes dual-fuel capability for the GM12000ED model.
попередньоview Genmax GM7250iEDC Inverter Generator User's Manual
Comprehensive user manual for the Genmax GM7250iEDC portable dual fuel inverter generator. Covers safety precautions, operating instructions, maintenance schedules, troubleshooting, and technical specifications for both gasoline and LPG use.
попередньоview Інструкція користувача портативного трипаливного генератора Genmax GM15000ET
Comprehensive user manual for the Genmax GM15000ET Tri-Fuel Portable Generator, covering safety, operation, assembly, maintenance, and technical specifications for gasoline, LPG, and natural gas.
попередньоview GENMAX GM7500iAED Inverter Generator User Manual: Safety, Operation, and Maintenance
Official user manual for the GENMAX GM7500iAED Portable Dual Fuel Inverter Generator. Covers setup, operation, safety precautions, maintenance schedule, troubleshooting, technical specifications, and choosing the right generator. Includes details on gasoline and LPG use.