ProCom MN180TPA-B

ProCom MN180TPA-B Natural Gas Ventless Infrared Plaque Heater User Manual

Model: MN180TPA-B

вступ

This manual provides essential information for the safe and efficient operation of your ProCom MN180TPA-B Natural Gas Ventless Infrared Plaque Heater. Please read all instructions carefully before installation, operation, or maintenance. Retain this manual for future reference.

ProCom MN180TPA-B Natural Gas Ventless Infrared Plaque Heater

Зображення: спереду view of the ProCom MN180TPA-B Natural Gas Ventless Infrared Plaque Heater, showcasing its compact design and infrared heating plaques.

Інформація про безпеку

Your ProCom heater is designed with safety in mind. It is a ventless unit, meaning it does not require an outside duct or chimney. However, proper ventilation is still crucial for safe operation. This heater is equipped with an Oxygen Depletion Sensor (ODS) that automatically shuts down the unit if oxygen levels become too low. It is ANSI Certified to ensure safety standards are met.

Особливості продукту

ProCom MN180TPA-B Features Diagram

Image: Diagram highlighting key features of the ProCom heater, including BTU output, ventless operation, natural gas compatibility, no electricity requirement, safety features, Piezo ignition, and thermostat mode.

Налаштування

The ProCom MN180TPA-B heater offers flexible installation options: wall-mounted or floor-standing.

Розпакування та перевірка

Вибір місця розташування

Select a location that allows for proper clearances from combustible materials. Ensure the area has adequate ventilation as per local codes and the heater's specifications.

Параметри встановлення

Підлога стоячи: Attach the included base feet to the bottom of the heater using the provided hardware. Ensure the heater is stable and level.

Настінне кріплення: Use the included wall mounting bracket and hardware. Follow the detailed instructions in the manufacturer's full installation guide for secure wall attachment and proper clearances.

ProCom MN180TPA-B Included Components

Image: Components included with the ProCom heater, showing the main unit, base feet, wall bracket, and highlighting the Oxygen Depletion Sensor and natural gas operation.

ProCom MN180TPA-B Wall Mounted

Image: The ProCom MN180TPA-B heater mounted on a wall in a living space, demonstrating its compact profile and integration into a room.

Підключення газу

This heater operates on natural gas only. Connection to the natural gas supply must be performed by a qualified professional in accordance with all local codes and regulations. Ensure all connections are leak-tested before operation.

Інструкція з експлуатації

Follow these steps to safely operate your ProCom MN180TPA-B heater.

Процедура запалювання

  1. Переконайтесь, що клапан подачі газу відкритий.
  2. Turn the control knob to the 'PILOT' position.
  3. Press and hold the control knob in while simultaneously pressing the Piezo ignition button repeatedly until the pilot flame ignites.
  4. Continue to hold the control knob in for approximately 30-60 seconds after the pilot ignites to allow the thermocouple to heat up. Release the knob; the pilot should remain lit.
  5. If the pilot does not remain lit, repeat steps 2-4.
  6. Once the pilot is stable, turn the control knob to the desired heat setting (1-5). The main burner will ignite.

Управління термостатом

The heater features a thermostat control with 5 variable heat settings. Rotate the control knob to select your preferred heat output. The heater will cycle on and off to maintain the set temperature.

ProCom MN180TPA-B Thermostat Controls

Зображення: Крупний план view of the control panel on the ProCom heater, showing the Piezo ignitor button and the rotary knob for 5 variable heat settings and pilot control.

Вимкнення обігрівача

  1. Поверніть ручку керування у положення «ВИМК.».
  2. For prolonged shutdown, close the main gas supply valve to the heater.

Технічне обслуговування

Регулярне технічне обслуговування забезпечує довговічність та безпечну роботу вашого обігрівача.

Усунення несправностей

If you encounter issues with your heater, refer to the following common problems and solutions. For persistent issues, contact a qualified service technician.

проблемаМожлива причинаРішення
Пілот не запалитьNo gas supply; Air in gas line; Pilot orifice clogged; Faulty thermocoupleCheck gas supply; Purge air from line; Clean pilot orifice; Contact technician
Pilot lights but will not stay litThermocouple not heating sufficiently; Loose thermocouple connection; Faulty ODS pilot assemblyHold knob longer; Tighten connection; Contact technician
Main burner will not ignitePilot not lit; Main burner orifice clogged; Low gas pressureEnsure pilot is lit; Clean burner orifice; Contact gas provider/technician
Heater cycles off frequentlyInsufficient ventilation; ODS activation; Thermostat setting too high for room sizeIncrease ventilation; Check for obstructions; Adjust thermostat setting

Технічні характеристики

АтрибутДеталь
БрендProCom
Номер моделіMN180TPA-B
Тип паливаПриродний газ
Maximum BTU Output18,000 BTU
Опалювальне покриттяДо 950 кв. футів.
Тип запалюванняPush Button Piezo
Тип управлінняThermostat (High/Medium/Low)
Функції безпекиOxygen Depletion Sensor (ODS)
Варіанти монтажуWall Mount, Floor Standing (Base Feet Included)
Розміри продукту8" Г x 22" Ш x 26" В
Вага товару26.2 фунта
КолірБілий
СертифікатиCSA Certified, ANSI Certified
ProCom MN180TPA-B Dimensions Diagram

Image: Diagram illustrating the dimensions of the ProCom MN180TPA-B heater: 24 inches H, 19 inches L, and 8 inches D.

Інформація про гарантію

For detailed warranty information regarding your ProCom MN180TPA-B Natural Gas Ventless Infrared Plaque Heater, please refer to the warranty card included with your product packaging or visit the official ProCom webсайт. Гарантійні умови можуть відрізнятися.

Підтримка клієнтів

If you require assistance, have questions about your heater, or need to report an issue, please contact ProCom customer support. Refer to your product packaging or the official ProCom website for the most current contact information, including phone numbers, email addresses, and online support resources.

Пов'язані документи - MN180TPA-B

попередньоview Procom NEW PRO-9900 AM/FM Citizens Band 2-Way Radio User Manual
User manual for the Procom NEW PRO-9900 AM/FM Citizens Band 2-Way Radio, detailing its functions, operations, features, and technical specifications for optimal use.
попередньоview PROCOM Atlas Loud Mouth Digital Wireless Intercom User Manual
This user manual provides comprehensive information on the PROCOM Atlas Loud Mouth Digital Wireless Intercom, including its features, operation, specifications, safety guidelines, and FCC compliance.
попередньоview ProCom Heating Vent-Free Gas Space Heater: Operation and Installation Manual
Comprehensive guide for ProCom Heating vent-free gas space heaters, covering installation, operation, safety, maintenance, and troubleshooting for models MN180TPA-B, ML150TPA-B, MN300TPA-B, and ML250TPA-B.
попередньоview ProCom Heating Vent-Free Gas Space Heater: Operation & Installation Manual
This manual provides essential guidance for the safe operation and installation of ProCom Heating's vent-free gas space heaters (MN180TPA-B, ML150TPA-B, MN300TPA-B, ML250TPA-B), covering safety, installation, operation, maintenance, and troubleshooting.
попередньоview Інструкція з експлуатації та встановлення газового настінного обігрівача ProCom Vent-Free
This manual provides operation and installation instructions for ProCom Vent-Free Gas Wall Heaters, including models MN2PHG, MN2PTG, MN3PHG, MN3PTG, ML2PHG, ML2PTG, ML3PHG, and ML3PTG. It covers safety precautions, product features, specifications, installation procedures, operation, troubleshooting, parts, accessories, and warranty information.
попередньоview Список запасних частин для внутрішніх блоків Bosch Climate серії 5000AA
Детальний список запасних частин та схема для внутрішнього блоку Bosch Climate серії 5000AA, включаючи номери деталей та інформацію про сумісність для різних потужностей BTU.