1. Продукт закінчивсяview
The Techbee Plug-in Electrical Meter Socket is an advanced device designed to help you monitor and manage your electricity consumption. It provides comprehensive data on various electrical parameters, allowing you to identify energy-intensive appliances and optimize your power usage for energy saving and environmental protection.

Figure 1.1: Techbee Plug-in Electrical Meter Socket Electricity Usage Monitor (Model JK-PM04) with its packaging.
Ключові характеристики:
- Energy-saving and Environmental Protection: Measures power consumption and calculates total energy costs for rational electricity planning.
- Multi-functional Monitoring: Offers 11 display modes including power (Watt), total energy used (kWh), carbon emissions (CO₂), voltage (Volt), current (Amp), frequency (Hz), power factor, cost per kWh, minimum power, and maximum power.
- Multi-layer Protection: Features warning indicators (screen flash and LED) for preset power, energy cost, or consumption limits. Default overload limit is 3680W, with a recommendation to set it to 1800W for initial use.
- User-friendly Display: Large, easy-to-read display set at a 45-degree angle for optimal visibility.
- Partial Reset Function: Allows deletion of measurement data without affecting original settings (e.g., cost/kWh).
- Вбудована батарея: Retains settings and measured data even when unplugged.
2. Налаштування та перше використання
Follow these steps to set up your Techbee Power Meter:
- Розпакування: Обережно вийміть вимірювач потужності з упаковки.
- Захисна плівка: A transparent protective film is present on the screen. You may remove it for clearer visibility or keep it as preferred.
- Увімкнення: Plug the meter directly into a standard electrical wall socket. The display should illuminate. If the screen remains blank or buttons are unresponsive, plugging it into a live socket will resolve the issue as it powers the internal battery and display.
- Initial Overload Setting: The default overload power limit is 3680W. Before using the energy meter, it is recommended to set the overload power to 1800W for general household appliances. Refer to Section 3.2 for instructions on setting alarm thresholds.
- Підключити пристрій: Підключіть прилад, який ви хочете контролювати, до розетки на передній панелі лічильника потужності.

Figure 2.1: The meter features a large display and a built-in battery for convenience.
3. Інструкція з експлуатації
The Techbee Power Meter features four control buttons: РЕЖИМ, НАБІР, UP, і ВНИЗ.
3.1. Режими відображення
Натисніть РЕЖИМ button to cycle through the 11 different display modes. Each mode provides specific electrical data:
- Watt / Total Cost: Displays current power consumption in Watts and accumulated cost.
- Total kWh Used: Shows the total kilowatt-hours consumed.
- Carbon Emissions (CO₂): Displays CO₂ emissions based on energy consumption.
- томtage / Частота: Показує поточний об'ємtage (V) and frequency (Hz) of the power supply.
- Current / Power Factor: Displays the current (Amp) and power factor.
- Cost per kWh: Дозволяє налаштування та viewing the cost per kilowatt-hour.
- Мінімальна потужність: Shows the lowest recorded power consumption.
- Максимальна потужність: Shows the highest recorded power consumption.
- Сигналізація перевантаження: Displays the set overload power limit.
- Alarm of kWh: Displays the set kWh alarm limit.
- Alarm of Cost: Displays the set cost alarm limit.

Малюнок 3.1: Закінченоview of the 11 monitoring modes available on the device.
3.2. Setting Alarm Thresholds and Cost
To set specific values like cost per kWh or alarm limits:
- Натисніть РЕЖИМ button until you reach the desired setting mode (e.g., "Cost per kWh", "Overload Alarm", "Alarm of kWh", or "Alarm of Cost").
- Натисніть НАБІР button. The digit you can adjust will start flashing.
- Використовуйте UP і ВНИЗ кнопки для налаштування значення.
- Прес НАБІР again to move to the next digit or to confirm the setting.
- Once all digits are set, press РЕЖИМ щоб вийти з режиму налаштування.

Figure 3.2: The device provides visual alarms (flashing LED and screen indicators) when set thresholds are exceeded.
3.3. Скидання даних
The meter allows for partial data reset, which means you can clear accumulated measurement data (like total kWh or total cost) without losing your custom settings (like cost per kWh or alarm thresholds). To reset measurement data, press and hold the ВНИЗ button for approximately 5 seconds until the relevant data clears.
3.4. Monitoring Appliance Consumption
The meter can precisely detect power usage down to 0.5W, allowing you to identify even the tiniest standby power consumption from your devices. This helps in tracking and reducing unnecessary electricity usage across various household appliances.

Figure 3.3: The power meter can be used to track consumption of various household appliances.
4. Технічне обслуговування
To ensure the longevity and accurate performance of your Techbee Power Meter, follow these maintenance guidelines:
- Прибирання: Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents, as they may damage the display or casing.
- Зберігання: Зберігайте глюкометр у прохолодному, сухому місці, подалі від прямих сонячних променів та екстремальних температур.
- Батарея: The meter includes a built-in Lithium Metal battery. This battery is not user-replaceable and is designed to retain settings and data when the device is unplugged.
- Уникайте вологи: Do not expose the device to water or high humidity. It is designed for indoor use only.
5. Вирішення проблем
If you encounter any issues with your Techbee Power Meter, refer to the following common problems and solutions:
| проблема | Можлива причина | Рішення |
|---|---|---|
| Screen is blank or buttons are unresponsive. | Meter is not receiving power or internal battery needs charging. | Plug the meter into a live electrical socket. This will power the unit and charge the internal battery. |
| Дисплей важко читати. | Lack of backlight in low-light conditions. | Use a flashlight to illuminate the screen for better visibility. Ensure adequate ambient lighting. |
| Overload alarm activates frequently. | Connected appliance exceeds the set overload limit. | Reduce the load on the circuit or adjust the overload limit if appropriate (refer to Section 3.2). Ensure the total wattage does not exceed the meter's maximum capacity (15A). |
| Data not resetting correctly. | Неправильна процедура скидання. | Переконайтеся, що ви натискаєте та утримуєте ВНИЗ button for approximately 5 seconds to perform a partial reset. |
6. Технічні характеристики
| Особливість | Специфікація |
|---|---|
| Номер моделі | JK-PM04 |
| Вага товару | 5.9 унції |
| Розміри упаковки | 6.73 x 3.23 x 2.52 дюймів |
| Джерело живлення | Провідний електричний |
| Точність вимірювання | ±2% |
| Включені компоненти | Ваттметр |
| Тип батареї | 1 літій-металева батарея (у комплекті) |
| Виробник | Shen Zhen He Yi Ke Ji You Xian Gong Si |
| Дата першої доступності | 16 липня 2023 р |
7. Гарантія та підтримка
Techbee stands behind the quality of its products. This product comes with a Гарантія 1 рік з дати покупки.
For any questions, technical assistance, or warranty claims, please contact Techbee customer service. We offer lifetime customer service to ensure your satisfaction with our products.
You can find more information and support resources by visiting the official Techbee store: Techbee Store on Amazon.