deleyCON CAT6a Flush-Mounted Network Socket Set (MK4209) Instruction Manual

Модель: MK4209

вступ

This manual provides detailed instructions for the installation, operation, and maintenance of the deleyCON CAT6a Flush-Mounted Network Socket Set. This set is designed to provide a secure and reliable network connection for both professional and home environments. It includes a network socket with an RJ45 port and a Keystone module for connecting network raw cables.

Вміст упаковки

Перевірте наявність усіх компонентів у вашій упаковці:

Components of the deleyCON CAT6a Network Socket Set including the flush-mounted socket, keystone module, and cable tie.

зображення: закінченоview of the deleyCON CAT6a Network Socket Set components, showing the flush-mounted socket, the keystone module, and a cable tie. Dimensions are also indicated.

Технічні характеристики

Номер моделі:MK4209
CAT Variant:CAT 6a (compatible with CAT5, CAT5e, CAT6, CAT7)
Екранування:STP Shielded (Keystone Module)
Network Socket Connection:1x RJ45 port for patch cable
Keystone Module Connection:RJ45 for network raw cable
Тип монтажу:Вбудовані
Матеріал корпусу:Metal (Keystone Module)
Приблизні розміри упаковки:8.5 х 8.5 х 5 см
Приблизна вага:85 г

Налаштування та встановлення

Follow these steps for proper installation of your deleyCON network socket set. Ensure power is disconnected before beginning any electrical work.

1. Prepare the Keystone Module

deleyCON CAT6a Keystone Module with wiring block and cable tie.

зображення: The deleyCON CAT6a Keystone Module, showing the wiring block detached and a cable tie for securing the cable.

  1. Carefully detach the wiring block from the keystone module.
  2. Strip approximately 2-3 cm of the outer jacket from your network raw cable (e.g., CAT6a). Do not strip the individual wire insulation.
  3. Following the color code diagram on the wiring block (T568A or T568B, typically T568B for most installations), insert each individual wire into its corresponding slot. Ensure the wires are fully seated.
  4. Use a punch-down tool to secure the wires and trim any excess. If a punch-down tool is not available, some keystone modules allow for tool-less termination by pressing the cover firmly.
  5. Once all wires are terminated, reattach the wiring block to the keystone module. Ensure it clicks securely into place.
  6. Use the provided cable tie to secure the network cable to the keystone module, providing strain relief.

2. Assemble the Network Socket

Вибухнув view of the deleyCON network socket assembly, showing the frame, cover, and keystone module.

зображення: An exploded diagram illustrating how the keystone module, mounting frame, and front cover assemble to form the complete flush-mounted network socket.

  1. Insert the prepared keystone module into the metal mounting frame. It should snap into place.
  2. Attach the front cover plate to the mounting frame. Ensure it aligns correctly and snaps securely.
Задня view of the assembled deleyCON network socket, showing the keystone module secured within the mounting frame.

зображення: Задня view of the assembled network socket, demonstrating how the keystone module is integrated into the mounting frame.

3. Mount the Socket

Фронт view of the deleyCON flush-mounted network socket frame, ready for installation.

зображення: Передня view of the deleyCON flush-mounted network socket's mounting frame, showing its design for integration into a wall box.

  1. Carefully push the assembled network socket into a standard flush-mounted wall box.
  2. Secure the socket to the wall box using appropriate screws (not included). Ensure it is firmly seated and level.
  3. Attach the outer decorative frame (if applicable and separate) to complete the installation.

Інструкція з експлуатації

Once the deleyCON CAT6a Network Socket is installed, its operation is straightforward:

  1. Connect one end of a standard RJ45 patch cable (e.g., CAT6a) to the RJ45 port on the installed network socket.
  2. Connect the other end of the patch cable to your network device (e.g., computer, router, switch).
  3. Verify network connectivity on your device.
Installed deleyCON network socket with an RJ45 patch cable connected to a wall outlet.

зображення: A deleyCON network socket installed in a wall, with an RJ45 patch cable plugged in, demonstrating typical usage.

Технічне обслуговування

The deleyCON CAT6a Network Socket requires minimal maintenance:

Усунення несправностей

Якщо у вас виникли проблеми з мережевим підключенням, виконайте такі дії з усунення несправностей:

Підтримка

For further assistance or technical support, please refer to the deleyCON official website or contact their customer service department. Keep your product model number (MK4209) handy when seeking support.