1. Вступ
This manual provides detailed instructions for the proper use and maintenance of your Traceable Calibrated Thermohygrometer with RS-232. This device is designed for accurate measurement of temperature and humidity, featuring microprocessor-based technology for easy calibration and an RS-232 output for data communication. For optimal performance and longevity, please read these instructions thoroughly before operation.

Image 1: The Traceable Calibrated Thermohygrometer. The device features a digital display showing humidity and temperature, with several control buttons below. A probe is connected via a coiled cable.
2. особливості
- Accurately measures temperature and relative humidity.
- Includes a NIST-Traceable certificate from an A2LA accredited calibration laboratory (1750.01), ensuring measurement accuracy.
- Microprocessor-based design facilitates quick and straightforward calibration procedures.
- Equipped with RS-232 output for data transmission to compatible systems.
3. Що в коробці
Upon unpacking, verify that the following items are present:
- Traceable Calibrated Thermohygrometer unit
- Humidity/Temperature Probe
- NIST-Traceable Calibration Certificate
- Інструкція з експлуатації
4. Налаштування
- Установка батареї: Open the battery compartment (typically on the back of the unit) and insert the required batteries, observing correct polarity.
- Підключення зонда: Connect the humidity/temperature probe to the designated port on the main unit. Ensure a secure connection.
- Початкове ввімкнення: Натисніть ON button to power on the device. The display should illuminate and show initial readings.
- Unit Selection (if applicable): If your model allows, select your preferred temperature unit (Celsius or Fahrenheit) using the ° C / ° F кнопку.
- Розміщення: Position the thermohygrometer in the environment where measurements are required. Ensure the probe is exposed to the air and not obstructed.
5. Інструкція з експлуатації
5.1 Основна операція
- Увімкнення/вимкнення живлення: Натисніть ON button to turn the unit on. Press the ВИМКНЕНО кнопку, щоб вимкнути його.
- Дисплей для читання: The display will show current relative humidity (RH%) and temperature (°C/°F).
- Одиниця вимірювання температури: Toggle between Celsius (°C) and Fahrenheit (°F) by pressing the ° C / ° F кнопку.
- Утримання даних: Натисніть ТРИМАТИ button to freeze the current readings on the display. Press again to release.
- Мінімальні/максимальні показники: Натисніть ХВІЛЬ / МАКС кнопку до view the minimum and maximum temperature and humidity readings recorded since the last reset. Press repeatedly to cycle through MIN, MAX, and current readings.
- Reset MIN/MAX: Поки viewing MIN/MAX readings, press the СКИДАННЯ button to clear the stored minimum and maximum values.
5.2 RS-232 Output
The device is equipped with an RS-232 port for connecting to a computer or data logger. This allows for real-time data acquisition and analysis. Refer to the specific software or interface instructions for your data collection system for details on establishing communication and data transfer protocols.

Image 2: A hand in a blue glove interacting with a Traceable device, demonstrating typical laboratory use. This image illustrates the practical application of Traceable instruments in a controlled environment.
6. Технічне обслуговування
- Прибирання: Wipe the unit and probe with a soft, damp тканина. Не використовуйте абразивні засоби чи розчинники.
- Заміна батареї: Replace batteries when the low battery indicator appears on the display. Ensure proper battery type and polarity.
- Зберігання: When not in use for extended periods, remove the batteries and store the device in a cool, dry place away from direct sunlight and extreme temperatures.
- Повторне калібрування: Due to the nature of humidity sensors, periodic recalibration is recommended to maintain accuracy. Refer to the NIST-Traceable certificate for recommended recalibration intervals.
7. Вирішення проблем
| проблема | Можлива причина | Рішення |
|---|---|---|
| Немає дисплея або тьмяний дисплей | Dead or weak batteries; incorrect battery installation. | Замініть батарейки на нові, дотримуючись правильної полярності. |
| Неточні показання | Sensor contamination; need for recalibration; probe not properly connected. | Clean the probe gently; perform recalibration; ensure probe is securely connected. |
| RS-232 communication failure | Incorrect cable; software settings mismatch; port issue. | Verify cable connection and type; check software communication settings (baud rate, parity); try a different USB/serial port. |
8. Технічні характеристики
| Параметр | Значення |
|---|---|
| Номер моделі | B07R5N7QYS |
| Виробник | КОУЛ-ПАРМЕР |
| Калібрування | NIST-Traceable (A2LA accredited 1750.01) |
| Інтерфейс | РС-232 |
| Дата першої доступності | 29 квітня 2019 р |
9. Гарантія та підтримка
For warranty information and technical support, please contact the manufacturer, Cole-Parmer, or your authorized distributor. Keep your purchase receipt and NIST-Traceable certificate for reference.
Виробник: КОУЛ-ПАРМЕР
Бренд: СЛІДОВИЙ
Щоб отримати додаткову допомогу, відвідайте Traceable Brand Store on Amazon.