CyberPower OL1000RTXL2UN

CyberPower OL1000RTXL2UN Smart App Online UPS: User Manual

Model: OL1000RTXL2UN | Brand: CyberPower

1. Вступ та опис продуктуview

The CyberPower OL1000RTXL2UN is a Smart App Online Uninterruptible Power Supply (UPS) designed to provide consistent, clean power for mission-critical equipment. This rack/tower convertible UPS features double-conversion topology, ensuring zero transfer time to battery power. It delivers pure sine wave output, essential for sensitive electronics, and includes an integrated network card for remote management.

Ключові особливості:

2. Візуалізація продукту

Задня view of CyberPower OL1000RTXL2UN UPS showing ports and outlets

Figure 1: Rear panel of the OL1000RTXL2UN UPS, highlighting the NEMA 5-15R outlets, EPO port, USB, RS232, and the pre-installed RMCARD205 network card.

CyberPower OL1000RTXL2UN UPS with key features labeled

Figure 2: The OL1000RTXL2UN UPS unit with an overview of its main features, including the 8 NEMA 5-15R outlets, EBM support, RMCARD205, and multifunction LCD panel.

CyberPower OL1000RTXL2UN UPS with dimensions labeled

Малюнок 3: Спереду view of the OL1000RTXL2UN UPS with its physical dimensions (17.00 inches width, 16.90 inches depth, 3.50 inches height) indicated.

Multiple CyberPower UPS units installed in a server rack

Figure 4: Multiple CyberPower UPS units, including the OL1000RTXL2UN, installed within a server rack, demonstrating its rack-mount capability.

CyberPower UPS units in a server rack with network cabling

Рисунок 5: Доводчик view of CyberPower UPS units in a server rack, showing network cabling connected to the integrated RMCARD205 for remote management.

3. Офіційні відео про продукт

Відео 1: Оверview of the CyberPower Smart App Online UPS Series, highlighting key features and applications for advanced IT environments.

Video 2: Detailed explanation of CyberPower Smart App Online UPS Systems, focusing on their role in mission-critical power protection.

4. Налаштування та встановлення

The OL1000RTXL2UN UPS can be installed in either a rack-mount or tower configuration. Ensure adequate ventilation around the unit, especially for the cooling fans located at the rear.

4.1 Фізичне розміщення

4.2 Електричні підключення

4.3 Network and Communication

5. Операція

The OL1000RTXL2UN operates as an online double-conversion UPS, providing continuous, regulated power to connected devices.

5.1 Double-Conversion Topology

This UPS continuously converts incoming AC power to DC, then back to AC. This process isolates connected equipment from utility power fluctuations, delivering a stable and clean sine wave output with zero transfer time during power events.

5.2 Вихід синусоїди

The pure sine wave output ensures compatibility with all types of equipment, especially sensitive electronics that may not function correctly with simulated sine wave power.

5.3 Generator Compatibility

The UPS is designed to work seamlessly with generators, ensuring that connected equipment receives stable power even when operating from a generator source.

5.4 Smart Battery Management

The Smart Battery Management system employs a three-cycle charging process (Charge, Float, Rest) that reduces heat and extends the overall lifespan of the UPS batteries.

5.5 GreenPower UPS™ ECO Mode

Activate the GreenPower UPS™ ECO Mode to improve UPS efficiency up to 97%, reducing energy consumption and operating costs.

5.6 Remote Monitoring and Management (RMCARD205)

The pre-installed RMCARD205 network card enables remote monitoring and control of the UPS via a standard web browser, Command Line Interface (CLI), or Network Management System (NMS). This allows for real-time status updates, event notifications, and scheduled shutdowns/reboots.

5.7 PowerPanel Business Edition Software

Utilize the FREE PowerPanel Business Edition Management Software (available for download) to monitor and control the UPS, receive event notifications, and manage scheduled shutdowns and reboots for connected systems.

6. Технічне обслуговування

Regular maintenance ensures the longevity and optimal performance of your CyberPower UPS.

6.1 Hot-Swappable Batteries

The OL1000RTXL2UN features hot-swappable batteries, allowing for battery replacement without shutting down connected equipment, thus eliminating downtime during maintenance.

6.2 Fast Charge Technology

This technology allows the UPS batteries to return to full capacity faster, typically within 4 hours for systems with Extended Battery Modules (EBMs), ensuring quick recovery after a power event.

6.3 Регулярне прибирання

Periodically inspect and clean the air filters and inflow screens to prevent dust buildup, which can impede airflow and affect cooling efficiency. Refer to the full manual for detailed cleaning instructions.

7. Вирішення проблем

If you encounter issues with your UPS, consult the following general troubleshooting advice. For detailed diagnostics and solutions, refer to the comprehensive user manual available on the CyberPower webсайт.

8. Технічні характеристики

СпецифікаціяЗначення
Номер моделіOL1000RTXL2UN
Ємність (ВА/Вт)1000 ВА/900 Вт
Вхідний об'ємtageNEMA 5-15P (10-foot cord)
Вихідні розетки8 x NEMA 5-15R
Форма вихідного сигналуСинусоїда
ТопологіяOnline Double-Conversion
Розміри (Д x Ш x В)16.9" Г x 17" Ш x 3.5" В
Вага товару39.6 фунта
Тип батареїSealed Lead Acid (3 x 12V included)
Мережева картаPre-installed RMCARD205
EBM OptionUp to ten optional BP36V60ART2U Extended Battery Modules

9. Гарантія та підтримка

The CyberPower OL1000RTXL2UN comes with a comprehensive warranty and support package:

For technical assistance, warranty claims, or additional information, please visit the official CyberPower webсайту або зв’яжіться зі службою підтримки клієнтів.

Пов'язані документи - OL1000RTXL2UN

попередньоview Посібник користувача та інструкція з безпеки ДБЖ CyberPower UT650EG / UT850EG
Посібник користувача для джерел безперебійного живлення (ДБЖ) CyberPower UT650EG та UT850EG, що охоплює інструкції з безпеки, встановлення, основні принципи роботи, світлодіодні індикатори, технічні характеристики та усунення несправностей.
попередньоview Посібник користувача ДБЖ CyberPower BRG1500AVRLCD2: характеристики, встановлення та експлуатація
Вичерпний посібник користувача для інтелектуального РК-ДБЖ CyberPower BRG1500AVRLCD2. Дізнайтеся про його функції, встановлення, основні принципи роботи, заміну батареї, усунення несправностей та технічні характеристики.
попередньоview CyberPower BP36V60ART2U & BP72V60ART2U Battery Pack User's Manual
Comprehensive user manual for CyberPower BP36V60ART2U and BP72V60ART2U Battery Packs. Includes installation guides, operational procedures, maintenance instructions, technical specifications, and troubleshooting tips for extending UPS runtime.
попередньоview Посібник користувача ДБЖ CyberPower BR700ELCD/BR1000ELCD/BR1200ELCD
Посібник користувача для джерел безперебійного живлення (ДБЖ) CyberPower BR700ELCD, BR1000ELCD та BR1200ELCD. Містить важливі інструкції з безпеки, інструкції з встановлення, технічні характеристики, основні відомості про експлуатацію та поради щодо усунення несправностей для надійного захисту живлення.
попередньоview CyberPower RMCARD205 Modbus TCP Register Map for 3-Phase UPS
This document provides the Modbus TCP register map for the CyberPower RMCARD205 Remote Management Card, detailing parameters, function codes, data formats, and a comprehensive list of registers for 3-Phase UPS systems.
попередньоview Посібник користувача інтелектуальних ДБЖ CyberPower серії OR1000LCDRM1U/OR1500LCDRM1U | Посібник із захисту живлення
Вичерпний посібник користувача для інтелектуальних ДБЖ CyberPower серії (OR1000LCDRM1U, OR1500LCDRM1U). Дізнайтеся про встановлення, функції, експлуатацію, заміну батареї, усунення несправностей, технічні характеристики та безпеку для надійного захисту живлення.