Model: 10178557 | Brand: MSA

вступ

The MSA ALTAIR 4XR Multigas Detector is a robust, handheld, portable gas monitor designed for critical safety applications. It is capable of simultaneously detecting up to four gases: Lower Explosive Limit (LEL), Oxygen (O2), Hydrogen Sulfide (H2S), and Carbon Monoxide (CO). Engineered for durability, this device features a tough over-molded rubber armor, is MIL-STD-810G drop protected, and boasts an IP68 rating for dust and water resistance, ensuring reliable performance in demanding environments.

MSA ALTAIR 4XR Multigas Detector front view

Малюнок 1: Спереду view of the MSA ALTAIR 4XR Multigas Detector, showing the display and control buttons.

Ключові характеристики

Налаштування та калібрування

Before initial use or after prolonged storage, it is essential to perform a fresh air setup (zero calibration) and a span calibration to ensure accurate readings. Always perform these procedures in a clean, fresh air environment free from contaminants.

Необхідне обладнання:

Zero Calibration (Fresh Air Setup):

  1. Power on the ALTAIR 4XR detector by pressing and holding the middle button. Allow it to complete its startup sequence and warm-up procedure.
  2. When prompted for a "Fresh Air Setup" (FAS), select "No" to proceed to normal operating mode. This ensures a high-quality zero calibration.
  3. Once in normal operating mode, press and hold the right button until the display shows "ZERO CAL?".
  4. Press the middle button to confirm "Zero Cal". The unit will enter "SENSOR REFRESH" mode. Ensure the detector is in a clean air environment, free from any gas sources or residual gas.
  5. Allow the unit to complete the zero calibration. The display will indicate when it's complete.

Калібрування діапазону:

  1. Ensure the calibration gas cylinder has the correct gas mixture and is not expired. The standard MSA calibration gas mixture includes: Hydrogen Sulfide (20 ppm), Carbon Monoxide (60 ppm), Pentane Simulant (58% LEL), Oxygen (15.0%), and Nitrogen (Balance).
  2. Attach the 0.25 L/min Regulator to the calibration gas cylinder. Ensure the regulator's valve is open slightly to purge any residual air before fully tightening it onto the cylinder. This prevents moisture from entering the cylinder.
  3. Connect the tubing from the regulator to the calibration adapter.
  4. Attach the calibration adapter to the MSA ALTAIR 4XR detector. The adapter should securely cover the sensor inlets.
  5. From the normal operating mode, press and hold the right button until the display shows "SPAN CAL?".
  6. Press the middle button to confirm "Span Cal". The unit will prompt for gas application.
  7. Immediately turn on the gas flow from the cylinder by opening the regulator valve. The detector will begin to read the gas concentrations.
  8. Monitor the display. The values for each gas (LEL, O2, H2S, CO) should stabilize near the concentrations listed on your calibration gas cylinder. The unit will indicate "SPAN PASS" when calibration is successful.
  9. Once "SPAN PASS" is displayed, turn off the gas flow and remove the calibration adapter and tubing from the detector.
Worker using MSA ALTAIR 4XR Multigas Detector in a confined space

Figure 2: The MSA ALTAIR 4XR Multigas Detector in use, demonstrating its compact size and clear display for field applications.

Операція

After successful calibration, the ALTAIR 4XR is ready for use. The large, clear display shows real-time gas concentrations. The unit continuously monitors the environment and will activate audible, visual (LEDs), and vibrating alarms if gas levels exceed predefined thresholds or if a man-down event is detected via MotionAlert.

Технічне обслуговування

Regular maintenance is crucial for the longevity and accuracy of your MSA ALTAIR 4XR. Keep the device clean and free from debris. Periodically inspect the sensor inlets for blockages. The unit is compatible with MSA GALAXY GX2 Automated Test System for simplified and automated bump testing and calibration, which also helps in managing data and records.

Sensors are designed for long life but may require replacement over time. The device will provide an "end-of-sensor-life" warning. Replacement MSA XCell Sensors are available and can be easily installed in the plug-and-play slots.

Усунення несправностей

If the device fails a bump test or calibration, first ensure that the calibration gas cylinder is not expired and contains the correct mixture. Check all connections for leaks. If sensor readings are erratic or consistently off, the sensor may be poisoned or at the end of its life and require replacement. For persistent issues, refer to the comprehensive troubleshooting guide in the full product manual or contact MSA support.

Технічні характеристики

СпецифікаціяЗначення
БрендMSA
СтильO2, H2S, CO
Джерело живленняПрацює від батареї
КолірЧОРНИЙ
Розміри продукту1.37" Г x 3" Ш x 4.4" В
Вага товару0.51 фунта (8.1 унції)
сигналізаціяAudible, Visual
Робоча вологість95 відсотків
Верхня температура50 градусів Цельсія
Тип датчикаCatalytic, Electrochemical
Кількість предметів1
ВиробникMSA
Номер деталі10178557
Номер моделі товару10178557
Дата першої доступності25 січня 2018 р

Гарантія та підтримка

This product is covered by a 4-year warranty. For more information regarding warranty claims or technical support, please visit the official MSA website or contact their customer service. Ensure to register your product to activate the warranty and receive important updates.

For additional assistance, you may also refer to the comprehensive product manual provided with your device or contact a certified MSA service center.

Пов'язані документи - 10178557

попередньоview Інструкція з експлуатації багатогазового детектора MSA ALTAIR 4XR
Вичерпний посібник з експлуатації багатогазового детектора MSA ALTAIR 4XR, що охоплює правила безпеки, опис пристрою, експлуатацію, технічне обслуговування, технічні дані та інформацію для замовлення.
попередньоview Автоматизована тестова система MSA GALAXY GX2 для газових детекторів
Автоматизована тестова система MSA GALAXY GX2 пропонує просте та інтелектуальне тестування та калібрування для одногазових детекторів MSA ALTAIR та ALTAIR PRO, а також багатогазових детекторів ALTAIR 4XR та ALTAIR 5X. Вона має простий у використанні інтерфейс, автоматизоване тестування та комплексні можливості управління парком пристроїв.
попередньоview Інструкція з експлуатації багатогазового детектора MSA ALTAIR 5X та 5XIR
Вичерпний посібник з експлуатації багатогазових детекторів MSA ALTAIR 5X та ALTAIR 5XIR, що охоплює правила безпеки, експлуатацію, технічне обслуговування, технічні характеристики та усунення несправностей для виявлення газів у промисловому середовищі.
попередньоview Зонд MSA ALTAIR для насосів: надійний газоаналізатор для небезпечних середовищ
Ознайомтеся з насосним зондом MSA ALTAIR – міцним та надійним приладом для виявлення газу. Дізнайтеся про його ключові характеристики, технічні характеристики, сертифікати та інформацію для замовлення в галузі промислової безпеки.
попередньоview Інструкція з експлуатації автоматизованої тестової системи MSA Galaxy GX2
Інструкція з експлуатації автоматизованої тестової системи MSA Galaxy GX2, що містить детальний опис встановлення, налаштування, експлуатації, технічного обслуговування та усунення несправностей під час тестування газових детекторів.
попередньоview Інструкція з експлуатації однофазного газоаналізатора MSA ALTAIR Pro - Посібник з безпеки та використання
Цей посібник з експлуатації містить детальні інструкції, правила техніки безпеки, процедури калібрування та усунення несправностей для однофазного газового детектора MSA ALTAIR Pro. Дізнайтеся, як ефективно використовувати та обслуговувати свій прилад для виявлення газу.