1. Вступ
This manual provides essential instructions for the setup, operation, and maintenance of your Antminer D3 19.3 GH/s X11 ASIC Dash Miner. Please read this document thoroughly before operating the device to ensure proper functionality and safety.

Figure 1: Antminer D3 19.3 GH/s X11 ASIC Dash Miner, front view.
2. Технічні характеристики
| Хеш-ставка | 19.3 GH/s (±5% variation expected) |
| Споживана потужність | 1200W (at the wall, with Bitmain’s APW3 PSU, 93% efficiency, 25°C ambient temp). Power consumption figures vary with PSU efficiency, ambient operating temperature, and power meter accuracy. |
| Розміри | 12.6 x 5.12 x 7.5 дюймів |
| Hashing Algorithm | X11 |
| Compatible Coins | DASH, ADZ, ARC, ATX, BOLI, BOPS, BSC, CANN, CNO, CNT, COXST, CREVA, CRM, DP, ENT, ERY, FAL, GILL, GRN, HCC, HPC, INFX, J-x11, KASH, KURT, LGBTQ, LKC, MAR, MARX, MMM, MND, MUE, OGN, ONX, OZC, PIZZA, PXI, SAND, SEV, SMC, START, TOR, TREAU, UIS-x11, VLTC, XCXT, XVP |
| Рекомендований блок живлення | APW3++ PSU (not included). One APW3++ PSU cannot power more than one Antminer D3. |
| Вага товару | 5 фунта |
| Апаратна платформа | Linux |
| Операційна система | Linux |

Figure 2: Visual representation of Antminer D3 specifications, including hash rate, power consumption, and dimensions.
3. Інструкції з налаштування
Follow these steps to properly set up your Antminer D3:
- Підключення до джерела живлення: Ensure you have a compatible power supply unit (PSU), such as the Bitmain APW3++. Connect the AC cable to the PSU adapter input.
- Hashing Board Connections: All PCIe connectors on each hashing board must be connected to the PSU. УВАГА: Do not connect more than one PSU to the same hashing board.
- Control Board Connection: Locate the additional 6-pin PCIe connector on the I/O board and connect it to the PSU.
- Послідовність увімкнення живлення: Only power on the miner after all PCIe connectors (for both hashing boards and the control board) are securely connected to the power supply.

малюнок 3: View of the Antminer D3's internal components, showing the hashing boards and PCIe power connectors. Ensure all connectors are properly seated.

Рисунок 4: Передня та задня частини views of the Antminer D3, highlighting the fan and port locations for proper setup.
4. Операція
Once the Antminer D3 is properly connected to power, it will initiate. The device operates using the X11 hashing algorithm to mine compatible cryptocurrencies such as Dash. Configuration details for mining pools and network settings are typically accessed via a web interface once the device is powered on and connected to your network. Refer to the specific software documentation for detailed configuration steps.
5. Технічне обслуговування
- Видалення пилу: Regularly clean the fans and heatsinks to prevent dust buildup, which can impede airflow and lead to overheating. Use compressed air or a soft brush.
- Екологічний контроль: Operate the miner in a cool, dry, and well-ventilated environment to maintain optimal operating temperatures and efficiency.
- Перевірка кабелю: Periodically inspect all power and data cables for any signs of wear or damage. Replace any compromised cables immediately.
6. Вирішення проблем
- Майнер не вмикається: Verify all power cables are securely connected to the PSU, hashing boards, and control board. Ensure the PSU is receiving power from the wall outlet.
- Низький хешрейт: Check network connectivity and mining pool settings. Ensure the ambient temperature is within the recommended range. Clean any dust from fans and heatsinks.
- Excessive Noise/Heat: This device is known to be very loud. Ensure proper ventilation and that fans are operating correctly. High temperatures can indicate insufficient cooling or dust buildup.
7. Інформація про безпеку
- Гучна робота: The Antminer D3 is very loud during operation. Prolonged exposure to high noise levels can be harmful. Consider using hearing protection or placing the miner in a sound-insulated area.
- Високе енергоспоживання: This device requires a 1200W power source. Ensure your electrical infrastructure can safely support this load to prevent electrical hazards.
- Генерація тепла: The miner generates significant heat. Ensure adequate ventilation to prevent overheating and potential fire hazards. Do not obstruct air vents.
- Електрична безпека: Always disconnect power before performing any maintenance or inspection. Do not operate the device with damaged cables or components.
8. Гарантія та підтримка
For warranty-related issues, please contact Bitmain directly. The seller does not handle returns or refunds for this product. It is important to note that the shipping address cannot be changed after an order has been submitted. The seller is not responsible for downtime caused by transportation delays due to customs formalities or other reasons.