The Planet GS-4210-16P4C is a high-performance Managed PoE+ Gigabit Switch designed for robust network applications. This device features IPv6/IPv4 dual stack management and a built-in L2/L4 Gigabit switching engine. It includes 16 10/100/1000BASE-T ports with 30-watt 802.3at Power over Ethernet Plus (PoE+) capabilities, alongside 4 additional Gigabit TP/SFP combo ports. With a total power budget of up to 220 watts, the GS-4210-16P4C offers a reliable and efficient Power over Ethernet solution for various network environments.
2. Продукт закінчивсяview
The GS-4210-16P4C switch integrates advanced features to enhance network reliability and management. Its intelligent PoE functions are designed to optimize the availability of connected Powered Devices (PDs).
Ключові характеристики:
- 16 10/100/1000T 802.3at PoE+ Ports
- 4 100/1000X SFP Ports
- Total Power Budget: 220 Watts @ 25°C, 190W @ 50°C
- Switch Throughput: 29.76Mpps
- Робоча температура: від 0° до 50°C
- Керування подвійним стеком IPv6/IPv4
- Intelligent PoE Functions (PD Alive Check, PoE Schedule)
Компонування передньої панелі:
The front panel of the GS-4210-16P4C switch provides access to all network ports and status indicators.

This image displays the front of the Planet GS-4210-16P4C switch. On the left, there is a console port and LED indicators for power, system status, and PoE activity. The central section features two blocks of eight 10/100/1000BASE-T PoE+ ports, totaling 16 ports. To the right, there are four Gigabit TP/SFP combo ports, offering flexible connectivity options.
Компонування задньої панелі:
The rear panel includes power input and cooling components.

This image shows the rear of the Planet GS-4210-16P4C switch. It features two cooling fans for thermal management, ensuring stable operation. On the far right, there is the AC power input socket and a power switch.
3. Налаштування
Follow these steps to set up your Planet GS-4210-16P4C switch:
- Розпакування: Carefully remove the switch from its packaging. Verify that all components are present, including the switch unit, power cord, and any included mounting hardware.
- Монтаж: The switch can be placed on a desktop or mounted in a standard 19-inch rack. Ensure adequate ventilation around the device to prevent overheating.
- Підключення живлення: Connect the provided AC power cord to the power input socket on the rear panel of the switch and then to a suitable power outlet. Ensure the power switch is in the OFF position before connecting.
- Мережні підключення:
- PoE+ Devices: Connect your Power over Ethernet (PoE) compatible devices (e.g., IP cameras, wireless access points) to the 16 10/100/1000BASE-T PoE+ ports using standard Ethernet cables.
- Uplink/Non-PoE Devices: Use the 4 Gigabit TP/SFP combo ports for uplink connections to other network devices or for connecting non-PoE Gigabit devices. SFP transceivers can be inserted into the SFP slots for fiber optic connections.
- Увімкнення: Flip the power switch on the rear panel to the ON position. Observe the LED indicators on the front panel to confirm proper power-up and system initialization.
- Початкова конфігурація: Доступ до комутатора web management interface via a connected computer. Refer to the separate software user manual for detailed instructions on initial IP address configuration and login procedures. The switch supports both IPv6 and IPv4 management.
4. Інструкція з експлуатації
The GS-4210-16P4C switch offers intelligent PoE functions to enhance network management and efficiency.
4.1 Intelligent PoE Functions
- PD Alive Check: The switch can be configured to monitor the status of connected Powered Devices (PDs) in real-time using ping actions. If a PD stops responding, the GS-4210-16P4C will automatically cycle the power on the corresponding PoE port, effectively rebooting the PD. This feature significantly improves network reliability by automatically restoring non-responsive devices and reduces the need for manual intervention.
- PoE Schedule: This function allows administrators to enable or disable PoE power feeding for each PoE port during specified time intervals. This is a powerful tool for energy saving, as it can power off devices during non-business hours. It also enhances security by ensuring that certain devices are only operational when needed. Additionally, the PoE schedule can be used to automatically reboot connected PoE IP cameras or wireless access points at a specific time each week, preventing potential crashes due to buffer overflow.
4.2 Web Інтерфейс управління
Перемикач web management interface provides comprehensive control and monitoring capabilities. Through this interface, you can:
- Configure network settings (IP addresses, VLANs, QoS).
- Manage PoE settings, including the PD Alive Check and PoE Schedule functions.
- Monitor the status of all ports and connected devices.
- View a power usage chart to track the real-time power consumption of connected PDs.
5. Технічне обслуговування
Regular maintenance ensures the optimal performance and longevity of your GS-4210-16P4C switch.
- Оновлення прошивки: Періодично перевіряйте дані виробника website for firmware updates. Applying the latest firmware can improve performance, add new features, and address security vulnerabilities.
- Умови навколишнього середовища: Ensure the switch operates within its specified temperature range (0° to 50°C) and humidity levels. Keep the area around the switch clear to allow for proper airflow and cooling.
- Прибирання: Gently clean the exterior of the switch with a soft, dry cloth. Do not use liquid or aerosol cleaners. Ensure ventilation openings are free from dust accumulation.
- PoE Device Reboot Schedule: Utilize the PoE schedule function to periodically reboot connected IP cameras or access points. This proactive measure can prevent device crashes and maintain consistent performance.
6. Вирішення проблем
If you encounter issues with your GS-4210-16P4C switch, consider the following troubleshooting steps:
- Немає живлення: Verify that the power cord is securely connected to both the switch and the power outlet. Check the power switch position and ensure the power outlet is functional.
- Немає підключення до мережі:
- Перевірте кабелі Ethernet на наявність надійних з'єднань та пошкоджень.
- Verify the link/activity LEDs on the switch ports and connected devices.
- Ensure IP address settings are correct for managed access.
- Пристрій PoE не вмикається:
- Confirm the connected device is PoE compatible and meets 802.3at standards.
- Перевірте світлодіод стану PoE для конкретного порту.
- Verify the total power budget is not exceeded. The switch has a 220W budget.
- Utilize the PD Alive Check feature to automatically restart non-responsive devices.
- Check the PoE schedule settings to ensure the port is enabled during operational hours.
- Повільна продуктивність мережі:
- Перевірте наявність надмірного мережевого трафіку або зациклень.
- Ensure cables are of appropriate quality and length.
- Review switch configuration for any bandwidth limitations or QoS settings.
- Доступ Web Інтерфейс: Ensure your computer's IP address is in the same subnet as the switch's management IP. Clear browser cache or try a different browser if issues persist.
7. Технічні характеристики
Detailed technical specifications for the Planet GS-4210-16P4C Managed PoE+ Gigabit Switch:
| Особливість | Специфікація |
|---|---|
| Номер моделі | GS-4210-16P4C |
| Порти | 16 x 10/100/1000BASE-T 802.3at PoE+ 4 x 100/1000X SFP (Combo) |
| Стандарт PoE | IEEE 802.3at/af |
| Загальний бюджет електроенергії | 220 Watts @ 25°C 190 Watts @ 50°C |
| Споживана потужність | 251 Watts / 861.2 BTU (Max) |
| Пропускна здатність комутатора | 29.76 Mpps |
| Комутаційна здатність | 40 Гбіт/с |
| Робоча температура | 0° до 50°C (32° до 122°F) |
| Розміри продукту (Д x Ш x В) | 17.32 x 11.81 x 1.75 дюйма (440 x 300 x 44.5 мм) |
| Вага товару | 9.09 фунта (4.12 кг) |
| Виробник | Планета Техніка |
| управління | IPv6/IPv4 Dual Stack, Web, SNMP, Telnet |
8. Інформація про безпеку
Будь ласка, дотримуйтесь наступних правил безпеки, щоб запобігти пошкодженню пристрою або травмуванню себе:
- Не відкривайте пристрій casing. Звертайтеся до кваліфікованого персоналу з усіх питань технічного обслуговування.
- Переконайтеся, що блок живлення обtagвідповідає вимогам, зазначеним на етикетці пристрою.
- Avoid placing the device in areas with high humidity, extreme temperatures, or direct sunlight.
- Не перекривайте вентиляційні отвори.
- Від’єднайте живлення перед чищенням або переміщенням пристрою.
9. Гарантія та підтримка
For warranty information and technical support, please refer to the documentation provided with your purchase or visit the official Planet Technology website. Contact their customer service for assistance with product registration, troubleshooting, or service requests.