ASHCROFT 1009AWL

ASHCROFT 1009AWL Pressure Gauge User Manual

Model: 1009AWL | Range: 0 to 400 psi

1. Вступ

This manual provides essential information for the proper installation, operation, and maintenance of your ASHCROFT 1009AWL Pressure Gauge. This general-purpose pressure gauge is designed for reliable measurement within a 0 to 400 psi range, featuring a 2-1/2 inch dial and liquid-filled construction for enhanced performance and durability.

Будь ласка, уважно прочитайте цей посібник перед використанням виробу, щоб забезпечити безпечну та ефективну роботу.

2. Інформація про безпеку

  • Межі тиску: Do not exceed the maximum rated pressure of 400 psi. Over-pressurization can cause gauge failure and potential injury.
  • Установка: Ensure the gauge is installed by qualified personnel using appropriate tools and sealing methods.
  • Сумісність системи: Verify that the gauge's wetted parts (Brass/Bronze) are compatible with the process media to prevent corrosion or damage.
  • Температурні обмеження: Operate the gauge within the specified temperature range of -20°F to 150°F. Extreme temperatures can affect accuracy and lifespan.
  • Обробка: Avoid dropping or subjecting the gauge to severe impact, as this can damage internal components.

3. Продукт закінчивсяview і компоненти

The ASHCROFT 1009AWL Pressure Gauge is constructed for durability and accurate readings. Key components include:

  • Циферблат: 2-1/2 inch diameter, clearly marked with 0-400 psi scale.
  • покажчик: Indicates the measured pressure.
  • Справа: Made from 304 Stainless Steel for corrosion resistance.
  • Об'єктив: Polycarbonate material for visibility and protection.
  • Підключення: 1/4 inch MNPT (Male National Pipe Taper) located at the bottom of the gauge.
  • Змочувані частини: Brass/Bronze construction ensures compatibility with various media.
  • Liquid Filling: Glycerin-filled for dampening pulsation and vibration, enhancing pointer stability and extending gauge life.
ASHCROFT 1009AWL Pressure Gauge, 0-400 psi

малюнок 1: ASHCROFT 1009AWL Pressure Gauge. This image displays the front view of the pressure gauge, showing the 0-400 psi dial, the ASHCROFT brand logo, and the bottom-mounted 1/4 inch MNPT connection.

4. Встановлення та налаштування

  1. Inspect Gauge: Before installation, visually inspect the gauge for any signs of damage. Do not install a damaged gauge.
  2. Підготовка підключення: Переконайтеся, що точка підключення системи чиста та не має сміття.
  3. Нанесіть герметик: Apply an appropriate thread sealant (e.g., PTFE tape or pipe dope) to the 1/4 inch MNPT threads of the gauge connection. Ensure sealant does not enter the gauge or system.
  4. Thread Gauge: Carefully thread the gauge into the system connection by hand until finger-tight.
  5. Затягнути: Using a wrench on the wrench flats of the gauge connection (not the case), tighten the gauge until secure. Avoid over-tightening, which can damage the threads or the gauge.
  6. Перевірте орієнтацію: Ensure the gauge dial is oriented for easy reading.
  7. Підвищення тиску в системі: Slowly pressurize the system and check for leaks at the connection point.

5. Операція

The ASHCROFT 1009AWL Pressure Gauge is designed for straightforward operation. Once properly installed, the gauge will continuously display the system pressure.

  • Зчитування показників манометра: Observe the pointer's position on the dial. The primary scale is in psi (pounds per square inch), ranging from 0 to 400. The smallest graduation is 10 psi.
  • Умови експлуатації: Ensure the operating environment and process media remain within the gauge's specified temperature range of -20°F to 150°F.
  • Точність: The gauge provides readings with an accuracy of +/-1.50% of full scale.
  • Пульсація: The glycerin filling helps to dampen pointer fluctuation in systems with pulsation or vibration, providing a more stable reading.

6. Технічне обслуговування

Regular maintenance ensures the longevity and accuracy of your pressure gauge.

  • Звичайна перевірка: Periodically inspect the gauge for any physical damage, such as a cracked lens, bent pointer, or corroded case.
  • Чистота: Keep the gauge lens clean to ensure clear visibility of the dial. Use a soft, damp тканину для очищення; уникайте абразивних мийних засобів.
  • Повторне калібрування: While ASHCROFT gauges are built for accuracy, prolonged use or exposure to harsh conditions may necessitate recalibration. Consult a qualified technician for recalibration services if accuracy is critical and suspected to be compromised.
  • Liquid Fill: The glycerin fill is sealed. If the liquid level appears significantly low or cloudy, the gauge may require replacement or professional servicing.

7. Вирішення проблем

Below are common issues and potential solutions for the ASHCROFT 1009AWL Pressure Gauge:

  • No Reading / Pointer Stuck:
    • Verify that the system is pressurized.
    • Check for blockages in the connection line to the gauge.
    • Inspect for physical damage to the gauge.
  • Неточне читання:
    • Ensure the gauge is operating within its specified temperature range.
    • Confirm the gauge's range is appropriate for the system pressure.
    • Consider professional recalibration if accuracy is critical and other factors are ruled out.
  • Leak at Connection:
    • Розгерметизуйте систему.
    • Re-apply thread sealant and re-tighten the connection.
    • Inspect threads for damage.
  • Liquid Fill Discoloration/Loss:
    • This may indicate a seal compromise or internal issue. The gauge may need replacement.

8. Технічні характеристики

Модель серії1009AWL
Діапазон тискувід 0 до 400 psi
Точність+/-1.50% of full scale
Nominal Dial Size2-1/2 дюйма
Розмір підключення1/4 inch MNPT
Місце підключенняДно
Матеріал корпусу304 Нержавіюча сталь
Змочені частиниBrass / Bronze
Матеріал лінзиПолікарбонат
Liquid FilledYes (Glycerin)
Діапазон робочих температурВід -20°F до 150°F (від -29°C до 66°C)
Розміри продукту (Д x Ш x В)4 x 3 x 1 дюймів
Вага товару1 фунт
UPC759426066021

9. Інформація про гарантію

The ASHCROFT 1009AWL Pressure Gauge comes with a 5-річна гарантія виробника. This warranty covers defects in materials and workmanship under normal use and service. For specific terms and conditions, please refer to the official ASHCROFT warranty statement or contact ASHCROFT customer support.

10. Підтримка клієнтів

For technical assistance, troubleshooting beyond this manual, or warranty claims, please contact ASHCROFT customer support directly. Visit the official ASHCROFT webсайт для отримання контактної інформації та додаткових ресурсів.

ASHCROFT Official Webсайт: www.ashcroft.com

Пов'язані документи - 1009AWL

попередньоview Керівництво з встановлення та обслуговування реле тиску швидкої дії Ashcroft B400 та B700
Цей посібник містить важливу інформацію щодо встановлення та обслуговування реле тиску швидкої дії Ashcroft серій B400 та B700. Він охоплює продукцію понадview, розміри, монтаж, електричні та кабельні з'єднання, процедури регулювання заданих значень та рекомендовані методи для безпечної та надійної експлуатації.
попередньоview Інструкції з встановлення манометрів/перемикачів диференціального тиску Ashcroft моделей 1130 та 1140
Інструкції з встановлення та технічні характеристики диференціальних манометрів Ashcroft моделей 1130 та 1140 з додатковими перемикачами. Охоплюють принципи роботи, встановлення, запобіжні заходи та підключення перемикачів.
попередньоview Ashcroft S1 Pressure Transducer: Features, Specifications, and Ordering Guide
Comprehensive data sheet for the Ashcroft S1 Pressure Transducer, detailing its features, typical uses, technical specifications, environmental and electrical ratings, output signals, ordering codes, and dimensional information.
попередньоview Ashcroft RXLdp Instruction Sheet: Installation and Operation Guide
Detailed instruction sheet for the Ashcroft Model RXLdp low differential pressure transducer, covering safety warnings, description, mounting, piping, power requirements, electrical connections, and dimensions.
попередньоview Керівництво з встановлення та обслуговування термопар та датчиків температури Ashcroft S10 та S50
Надає детальні інструкції з встановлення та обслуговування датчиків температури Ashcroft S10 та S50 із RTD та термопарами. Охоплює загальні запобіжні заходи, зберігання, конкретні процедури встановлення датчиків температури та термопар, а також рекомендації щодо технічного обслуговування для забезпечення точних вимірювань та довговічності.
попередньоview Передавач тиску високої чистоти Ashcroft ZX12: Керівництво з встановлення та обслуговування
Вичерпні інструкції з встановлення та обслуговування високочистого перетворювача тиску Ashcroft ZX12, що охоплюють запобіжні заходи, підключення, експлуатацію, калібрування та інформацію про гарантію.