This manual provides detailed instructions for the proper use and maintenance of your Apera Instruments Salt20 Salinity Tester Kit. The Salt20 is designed for professional salinity measurement in various water solutions, including pools, spas, agriculture, and environmental monitoring.

For optimal performance and longevity of your device, please read this manual thoroughly before operation.

Apera Instruments Salt20 Salinity Tester Kit showing applications in hydroponics, pools, and drinking water.

The Apera Instruments Salt20 Salinity Tester is suitable for a wide range of applications including hydroponics, pools, and drinking water analysis.

Техніка безпеки

Важлива інформація з безпеки

Продукт закінченийview

Компоненти набору

Apera Instruments Salt20 Salinity Tester Kit with meter, calibration solution, and carrying case.

The Salt20 Salinity Tester Kit includes the meter, calibration solution, AAA batteries, and a lanyard, all housed in a portable carrying case.

The Apera Instruments Salt20 Salinity Tester Kit includes:

Ключові характеристики

Сенсорні технології

Close-up of the Apera Instruments Salt20 BPB EC sensor.

The Salt20 features Apera's unique Brush-Resistant Platinum Black (BPB) sensor, designed for high accuracy and consistency in wide-range salinity testing.

Деталі РК-дисплея

Diagram of the Apera Instruments Salt20 LCD display showing measurement values, temperature, stable reading reminder, and calibration success symbol.

The clear LCD display provides simultaneous readings for salinity (ppt) and temperature, along with indicators for stable readings and successful calibration.

Аксесуари

Hand holding the Apera Instruments Salt20 Salinity Tester with an attached lanyard.

A lanyard is included for convenient and secure use of the Salt20 Salinity Tester.

Person holding the rugged carrying case for the Apera Instruments Salt20 Salinity Tester Kit.

The complete test kit comes in a rugged carrying case for protection and portability.

Налаштування

Установка батареї

The Salt20 Salinity Tester is powered by 4 AAA batteries.

  1. Відкрутіть кришку батарейного відсіку у верхній частині глюкометра.
  2. Insert the AAA batteries according to the polarity indicators (+/-).
  3. Securely screw the battery cap back on to ensure the waterproof seal.

Початкова підготовка

  1. Зніміть захисний ковпачок з датчика.
  2. Rinse the sensor with distilled water and gently shake off excess water.
  3. The meter is now ready for calibration or measurement.

Інструкція з експлуатації

Основні вимірювання

  1. Увімкнути: Short press the MEAS button to turn on the meter.
  2. Immerse Sensor: Dip the sensor into the sample solution, ensuring the solution covers the sensor completely. Stir gently to remove air bubbles.
  3. Зчитування вимірювань: Wait for the smiley face icon to appear and remain stable on the LCD, indicating a stable reading. Record the salinity (ppt) and temperature (°C/°F) values.
  4. Вимкнути: Long press the MEAS button to turn off the meter.

Блоки комутації

To switch between °C and °F, with the meter turned off, long press the CAL button until the unit changes.

Офіційне відео продукту

Watch this official video from Apera Instruments for a visual guide on using the Salt20 Salinity Tester Kit. This video provides an overview of the product's features and basic operation.

Калібрування

1-Point Auto Calibration

The Salt20 Salinity Tester uses a 1-point auto calibration process with auto buffer recognition. It is recommended to calibrate the meter regularly for accurate results, especially before critical measurements or if the meter has not been used for a long time.

Diagram showing the calibration process for the Apera Instruments Salt20 Salinity Tester.

The Salt20 Salinity Tester features effortless single-button auto calibration with auto buffer recognition, simplifying the calibration process.

  1. Приготувати розчин: Pour a small amount of the 12.88 mS/cm (6.44 ppt) calibration solution into a clean beaker.
  2. Увійдіть у режим калібрування: With the meter turned on, short press the CAL button. The display will show "CAL" and the calibration value.
  3. Immerse Sensor: Dip the sensor into the calibration solution. Stir gently.
  4. Зачекайте на стабільність: The meter will automatically recognize the calibration solution. Wait for the smiley face icon to appear and remain stable. The calibration success symbol (M) will also appear.
  5. Вихід із калібрування: Short press the MEAS button to exit calibration mode and return to measurement mode.

Примітка: Always use fresh calibration solution for each calibration. Do not pour used solution back into the bottle.

Технічне обслуговування

Очищення датчика

The BPB (Brush-Resistant Platinum Black) sensor is robust but requires proper cleaning to maintain accuracy.

  1. After each use, rinse the sensor thoroughly with distilled or deionized water.
  2. If there is visible contamination, gently brush the sensor with a soft brush (like a soft toothbrush) while rinsing.
  3. For stubborn deposits, soak the sensor in a mild detergent solution for 10-15 minutes, then rinse thoroughly.
  4. Ніколи wipe the sensor with abrasive materials or apply excessive force, as this can damage the platinum black coating.

Зберігання

For long-term storage, ensure the sensor is clean and dry. Replace the protective cap. Store the meter in its carrying case in a cool, dry place.

Усунення несправностей

Поширені проблеми та рішення

ВипускМожлива причинаРішення
Неточні показанняSensor dirty; Calibration needed; Expired calibration solutionClean sensor; Perform calibration; Use fresh calibration solution
No Display / Meter Won't Turn OnРозряджені батарейки; неправильне встановлення батарейокЗамініть батарейки; перевірте полярність батарейок
"Out-of-Range" WarningSalinity level exceeds 10.0 pptThe meter's range is 0-10.0 ppt. For higher ranges, a different meter is required.
Повільна відповідьСенсор потребує очищенняClean the sensor thoroughly

Технічні характеристики

Технічні характеристики

ПараметрЗначення
Діапазон солоності0 - 10.0 ppt
Salinity Accuracy± 1% ФС
Діапазон температур0 - 50°C (32 - 122°F)
Температурна компенсаціяAutomatic (0-50°C)
КалібруванняAuto 1-point
Джерело живлення4 батареї AAA
Термін служби батареїДо 1000 годин
Рейтинг водонепроникностіIP67 (Dust-proof and Water-proof, Floatable)
Автоматичне вимкнення8 minutes of no operation
Розміри7.01 x 1.61 x 1.18 дюймів
вага3.8 унції

Гарантія та підтримка

Інформація про гарантію

Apera Instruments provides a limited warranty for its products. Please refer to the official Apera Instruments webна сайті або в гарантійному талоні, що додається до вашого продукту, щоб дізнатися про конкретні гарантійні умови.

Підтримка клієнтів

For technical assistance, troubleshooting, or inquiries about replacement parts and accessories, please contact Apera Instruments customer support.

Webсайт: www.aperainst.com

Електронна пошта: Refer to your product documentation for specific contact email.

телефон: Refer to your product documentation for specific contact phone number.

Пов'язані документи - AI214

попередньоview Інструкція з експлуатації кишенькового тестеру солоності Apera Instruments Salt20
Інструкція з експлуатації кишенькового соломіра Apera Instruments Salt20, що охоплює встановлення батареї, функції клавіатури, калібрування, вимірювання солоності, технічні характеристики та гарантійну інформацію.
попередньоview Інструкція з експлуатації кишенькового соломіра SALT20 - Apera Instruments
Інструкція користувача для кишенькового соломіра Apera Instruments SALT20, що охоплює встановлення, експлуатацію, калібрування, технічні характеристики та гарантійну інформацію, надану Labco Scientific.
попередньоview Посібник користувача тестера Apera Instruments PC60 Premium 5-в-1
Вичерпний посібник користувача для тестера Apera Instruments PC60 Premium 5-в-1, що охоплює вимірювання pH, провідності, TDS, солоності та температури. Містить інструкції з налаштування, калібрування, експлуатації, обслуговування та усунення несправностей.
попередньоview Apera Instruments 5052 Seawater Salinity Pocket Tester Operation Manual
Detailed operation manual for the Apera Instruments 5052 Seawater Salinity Pocket Tester, covering technical parameters, calibration, measurement procedures, important notes, and warranty information.
попередньоview Кишеньковий тестер провідності Apera EC20: інструкція з експлуатації та посібник
Вичерпний посібник з експлуатації кишенькового тестера провідності Apera EC20. Дізнайтеся про налаштування, калібрування, вимірювання провідності, технічні характеристики та гарантійну інформацію.
попередньоview Apera PH20 Value pH Tester Kit User Manual - Guide and Specifications
This user manual provides comprehensive instructions for the Apera PH20 Value pH Tester Kit, covering setup, calibration, measurement, maintenance, troubleshooting, and technical specifications. Learn how to use and care for your pH tester.