СИМПЛЕКС 4099-9005

Simplex 4099-9005 Addressable Manual Pull Station (Dual Action) User Manual

Модель: 4099-9005

1. Вступ

The Simplex 4099-9005 is an addressable manual pull station designed for use with compatible Simplex fire alarm control panels. This dual-action device requires two distinct operations to activate, reducing the likelihood of accidental activation. It is an integral component of a comprehensive fire detection and alarm system, providing a manual means for occupants to initiate an alarm in the event of a fire or other emergency.

2. Інформація про безпеку

Важливі інструкції з безпеки:

3. Продукт закінчивсяview

The Simplex 4099-9005 is a red, dual-action manual pull station. Its addressable nature allows the fire alarm control panel to identify the exact location of the activated station. The dual-action design requires a two-step process for activation: first, pushing in a bar, and then pulling down a handle.

Фронт view of the Simplex 4099-9005 Addressable Manual Pull Station, showing the 'FIRE ALARM' label, 'PUSH BAR', and 'PULL HANDLE'.

Малюнок 1: Спереду view of the Simplex 4099-9005 Addressable Manual Pull Station. This image displays the primary components including the 'FIRE ALARM' text, the 'PUSH BAR' mechanism, and the 'PULL HANDLE' for activation.

4. Монтаж

Proper installation is crucial for the reliable operation of the manual pull station.

4.1 Монтаж

4.2 Електропроводка

4.3 Налаштування адреси

The 4099-9005 is an addressable device. Before connecting to the SLC, set the unique address for the pull station using the appropriate Simplex programming tool or DIP switches, as specified in the device's technical documentation. Each device on the SLC must have a unique address.

сторона view of the Simplex 4099-9005 Addressable Manual Pull Station, showing its depth and mounting points.

Малюнок 2: Сторона view of the Simplex 4099-9005 Addressable Manual Pull Station. This image illustrates the depth of the unit and provides a perspective on its mounting configuration.

5. Операція

5.1 Активація сигналізації

In the event of a fire or emergency, follow these steps to activate the manual pull station:

  1. Натисніть: Firmly push the bar labeled "PUSH BAR" on the front of the station.
  2. Потягни вниз: Once the bar is pushed in, pull down the handle labeled "PULL HANDLE" until it latches in the down position.

Activation will send an alarm signal to the fire alarm control panel, initiating the building's alarm sequence.

5.2 Скидання налаштувань витяжної станції

After an alarm has been activated and the emergency resolved, the pull station must be reset. The Simplex 4099-9005 requires a B-Key for resetting.

  1. Insert B-Key: Locate the keyhole on the front of the pull station. Insert the B-Key into the keyhole.
  2. Під ключ: Turn the B-Key clockwise or counter-clockwise (depending on the specific mechanism) to release the latched handle.
  3. Закрити обкладинку: Return the handle to its original, unactivated position and close the front cover.
  4. Remove B-Key: Remove the B-Key.

The B-Key is considered a tool for maintenance and resetting, not a consumable item. If additional B-Keys are required, they can be ordered using PID: 252-019.

6. Технічне обслуговування

Regular maintenance ensures the continued reliability of your Simplex 4099-9005 pull station.

7. Вирішення проблем

If you encounter issues with your Simplex 4099-9005 pull station, consider the following:

For persistent issues, contact a qualified fire alarm technician.

8. Технічні характеристики

ОсобливістьСпецифікація
БрендПРОСТИЙ
Номер моделі4099-9005
СтильБезпека
Джерело живленняІнструкція
Вага товару3.53 унції (100 грама)
Тип тривогиAudible (via FACP)
матеріалGlass (referring to break-glass type, though this model is dual-action)
Розміри продукту1 x 3.4 x 5 дюймів
UPC643485652991
Номер деталіS4099-9005
Потрібні батареїнемає

9. Інформація про гарантію

Specific warranty details for the Simplex 4099-9005 Addressable Manual Pull Station are typically provided at the point of purchase or can be obtained directly from Simplex or an authorized distributor. Please retain your proof of purchase for warranty claims. For detailed warranty terms and conditions, refer to the official Simplex documentation or contact their customer service.

10. Підтримка клієнтів

For technical assistance, installation queries, or service requests, please contact your authorized Simplex dealer or a certified fire alarm technician. Ensure you have the product model number (4099-9005) and any relevant system information available when seeking support.

Пов'язані документи - 4099-9005

попередньоview Simplex IDNet/MAPNET II Addressable Manual Fire Alarm Stations - Product Data
Detailed information on Simplex 4099 Series addressable manual fire alarm stations, compatible with IDNet and MAPNET II systems. Features, specifications, mounting options, and product selection for various models, including single action, double action (breakglass and push), and NO GRIP options. Compliant with ADA requirements and listed by UL, ULC, FM, and CSFM.
попередньоview Simplex Addressable Manual Stations: IDNet/MAPNET II Peripherals
Explore Simplex addressable manual fire alarm stations, detailing their features, single/double action types, NO GRIP options, and compatibility with IDNet/MAPNET II systems. Includes mounting and specification information.
попередньоview Simplex 2099 Series Single and Double Action Manual Fire Alarm Stations Datasheet
Datasheet for Simplex 2099 Series non-coded, non-addressable manual fire alarm pull stations. Covers features, operation types, application references, product selection, mounting options, and specifications.
попередньоview Simplex 4010ES: система автоматичного гасіння для гігієни
Посібник Simplex 4010ES докладно описує командні модулі для автоматичних систем гасіння для пристроїв, які відповідають режимам потоплення та запобіганню, а також специфікаціям, омологаціям та схемам кабелю.
попередньоview Панель керування пожежною сигналізацією Simplex 4004: інструкції з встановлення та експлуатації
Вичерпний посібник з встановлення, експлуатації та програмування пожежної сигналізації Simplex 4004 (FACP), включаючи системуview, вимоги, підключення, описи модулів та усунення несправностей.
попередньоview Simplex 4100ES Addressable Fire Detection and Control Panels: Features, Modules, and Specifications
Детально надview of the Simplex 4100ES Series Fire Control Panels, covering features, addressable device control, module selection, system operation, and technical specifications for fire detection and alarm systems.