This manual provides essential information for the safe and effective installation, operation, and maintenance of the Idec RH2B-UL-AC110-120V Electromechanical Relay. Please read this manual thoroughly before using the product to ensure proper function and to prevent potential hazards.
Інформація про безпеку
WARNING: Electrical shock hazard. Installation and maintenance should only be performed by qualified personnel. Disconnect all power before working with the relay.
- Always ensure power is disconnected before installation, wiring, or maintenance.
- Перевірте правильний томtage and current ratings before connecting the relay to a circuit.
- Do not operate the relay in environments exceeding its specified temperature or humidity limits.
- Ensure proper grounding where applicable.
Продукт закінченийview
The Idec RH2B-UL-AC110-120V is a general-purpose electromechanical relay designed for various industrial control applications. It features a compact design and is suitable for DIN rail mounting.

Figure 1: Idec RH2B-UL-AC110-120V Relays in their original packaging, showing a pack of four units.

Figure 2: A single Idec RH2B-UL-AC110-120V relay, providing an angled view of the transparent casing та внутрішні компоненти.
Налаштування та встановлення
Follow these steps for proper installation of the Idec RH2B-UL-AC110-120V Relay:
- Відключення живлення: Ensure all power to the circuit is completely disconnected before beginning installation.
- Монтаж: The relay is designed for DIN Rail mounting. Securely attach the relay to a standard DIN rail in your control panel.
- Електропроводка: The relay utilizes through-hole connectors. Carefully connect the control circuit wiring to the coil terminals and the load circuit wiring to the contact terminals. Refer to the wiring diagram (if available in your system documentation) for specific terminal assignments.

Малюнок 3: Нижня частина view of the relay, showing the through-hole connector pins for wiring connections.
- томtage Перевірка: Підтвердьте, що обсяг постачання обtage for the coil matches the relay's specified voltage 110-120 В змінного струму, 50/60 Гц.

Малюнок 4: Збільшений план view of the relay's transparent casing, highlighting the model number and voltage specifications (AC110-120V, 50/60Hz).
- Load Verification: Ensure the connected load does not exceed the relay's contact ratings (e.g., 10A resistive at 240VAC).

Малюнок 5: Сторона view of the relay, displaying detailed electrical ratings and certifications.
- Остаточна перевірка: Before restoring power, double-check all connections for security and correctness.
Інструкція з експлуатації
The Idec RH2B-UL-AC110-120V Relay operates automatically based on the control signal applied to its coil. When the specified AC voltage (110-120V) is applied to the coil, the relay contacts will switch, opening or closing the connected load circuit. When the voltage is removed, the contacts return to their original state.
- Ensure the control signal is within the specified voltagдіапазон для надійної роботи.
- Observe any indicator lights on the relay (if present) to confirm coil energization.
Технічне обслуговування
The Idec RH2B-UL-AC110-120V Relay is designed for long-term, reliable operation with minimal maintenance. However, periodic inspection is recommended:
- Візуальний огляд: Періодично перевіряйте реле на наявність будь-яких ознак фізичних пошкоджень, зміни кольору або нещільних з'єднань.
- Прибирання: За потреби обережно очистіть зовнішню частину реле сухою м’якою тканиною. Не використовуйте розчинники або абразивні засоби для чищення.
- Contact Inspection: In critical applications, inspect contacts for pitting or wear. Replace the relay if significant wear is observed.
- Умови навколишнього середовища: Забезпечте дотримання заданих температурних та вологісних умов у робочому середовищі, щоб запобігти передчасному виходу з ладу.
Усунення несправностей
Якщо реле не працює належним чином, зверніть увагу на такі поширені проблеми:
| проблема | Можлива причина | Рішення |
|---|---|---|
| Relay coil does not energize. | Немає живлення котушки, неправильний об'ємtage, faulty wiring, or damaged coil. | Перевірте блок живлення, перевірте гучністьtage (110-120V AC), inspect wiring connections, test coil continuity. |
| Contacts do not switch. | Coil not energizing, contacts welded, or mechanical failure. | Refer to "Relay coil does not energize" solutions. If coil is good, replace relay. |
| Load not receiving power. | Relay contacts not closing, open circuit in load wiring, or faulty load. | Verify relay operation. Check load circuit wiring and the load itself. |
If troubleshooting steps do not resolve the issue, contact Idec technical support or a qualified electrician.
Технічні характеристики
| Параметр | Значення |
|---|---|
| Номер моделі | RH2B-UL-AC110-120V |
| Бренд | Idec |
| Coil Voltage | 110-120V AC |
| Частота | 50/60 Гц |
| Current Rating (Resistive) | 10A @ 240VAC, 10A @ 30VDC |
| Current Rating (General Use) | 7.5A @ 120VAC, 7A @ 240VAC, 7.5A @ 30VDC |
| Рейтинг кінських сил | 1/6 HP @ 120VAC, 1/3 HP @ 240VAC |
| Тип монтажу | Кріплення DIN на рейці |
| Тип роз'єму | Наскрізний отвір |
| Режим роботи | Автоматичний |
| Вага товару | 0.01 унції |
| Виробник | Idec |
Гарантія та підтримка
For warranty information and technical support, please contact Idec directly through their official webсайт або канали обслуговування клієнтів. Зберігайте чек про покупку для гарантійних претензій.
Idec Official Webсайт: us.idec.com