KEYSIGHT U1253B

KEYSIGHT U1253B Handheld Digital Multimeter User Manual

1. Вступ і даліview

The Keysight U1253B is a 4.5-digit handheld digital multimeter (DMM) designed for troubleshooting electronics and electrical circuits. It features an Organic LED (OLED) display for clear readings in various lighting conditions, including dark or off-angle situations. This DMM includes an integrated 20 MHz frequency counter, a built-in programmable square-wave generator, and data-logging capabilities for PC integration.

KEYSIGHT U1253B Handheld Digital Multimeter front view

Малюнок 1: Спереду view of the KEYSIGHT U1253B Handheld Digital Multimeter, showing the OLED display, rotary dial, and function buttons.

2. Інформація про безпеку

Цей продукт призначений лише для професійного використання.

Keysight Technologies products are classified as industrial monitoring and control equipment designed exclusively for professional or industrial use and related training programs. Keysight products are designed and certified to meet national industrial safety standards (such as Electrical Equipment for Measurement, Control and Laboratory Use) where products are sold solely for use by trained professionals. Keysight products are not intended for consumer use in a residential setting and may not meet consumer level standards for EMC and other regulated radiated emissions. Keysight products are intended for use in the country where the product was originally sold.

Always adhere to local and national safety regulations when operating the device. Ensure proper insulation and grounding practices are followed to prevent electrical shock or damage to the instrument.

3. Особливості продукту

  • 30,000 counts resolution for precise measurements.
  • 0.7% accuracy for AC voltagе вимірювання.
  • Low Pass Filter (LPF) for accurate readings in noisy environments.
  • Quick signal type identification (Qik-V).
  • Internal memory capable of storing up to 200 data points for logging.
  • Dust and water resistant casing (IP 54 compliant) for enhanced durability.
  • Organic LED (OLED) display for superior visibility.
  • Integrated 20 MHz frequency counter.
  • Built-in programmable square-wave generator with selectable frequency and duty cycle.

4. Налаштування

4.1 Встановлення та заряджання акумулятора

The U1253B uses a rechargeable 9-volt battery. To install or replace the battery, refer to the back panel of the device. Ensure the battery is correctly oriented according to the polarity markings. Use the provided charger to fully charge the battery before initial use. Regular charging is recommended due to the OLED display's power consumption.

Назад view of the KEYSIGHT U1253B Handheld Digital Multimeter, showing the battery compartment and stand.

Малюнок 2: Задня частина view of the multimeter, indicating the battery compartment.

4.2 Підключення вимірювальних щупів

Insert the test leads into the appropriate input jacks on the front panel of the multimeter. For most measurements, the black lead connects to the 'COM' (common) jack, and the red lead connects to the 'V Ω Hz' or 'A' (current) jack depending on the measurement type. Always ensure secure connections.

5. Інструкція з експлуатації

5.1 Основна операція

Turn the rotary dial to the desired measurement function. The OLED display will show the selected function and measurement range. Use the 'Range' button to manually select a range or allow the DMM to auto-range. The 'Hold' button can freeze the current reading on the display.

Під кутом view of the KEYSIGHT U1253B Handheld Digital Multimeter, highlighting the display and controls.

Рисунок 3: Кутовий view of the multimeter, showing the display and control layout.

5.2 томtagВимірювання (змінний/постійний струм)

Rotate the dial to the 'V∼' (AC Voltage) or 'V—' (DC Voltage) position. Connect the test leads in parallel to the circuit or component under test. The display will show the voltage reading. Use the 'Shift' button to toggle between AC and DC if the dial position covers both.

5.3 Вимірювання струму (змінного/постійного струму)

Rotate the dial to the 'A∼' (AC Current) or 'A—' (DC Current) position. Ensure the red test lead is connected to the appropriate current input jack (e.g., 'mA µA' or 'A'). Connect the DMM in series with the circuit. Exercise caution when measuring current, as incorrect connection can damage the meter or circuit.

5.4 Вимірювання опору

Turn the dial to the 'Ω' (Resistance) position. Connect the test leads across the component to measure its resistance. Ensure the circuit is de-energized before measuring resistance.

5.5 Frequency Counter

To use the integrated 20 MHz frequency counter, select the 'Hz' function. Connect the test leads to the signal source. The DMM will display the frequency of the input signal.

5.6 Square-Wave Generator

The U1253B includes a programmable square-wave generator. Refer to the detailed manual for specific instructions on setting frequency and duty cycle for output generation.

5.7 Реєстрація даних

The DMM has internal memory for up to 200 data points. For extended data logging and analysis, utilize the easy-to-use GUI data-logging software provided by Keysight, which allows for automated and virtually unlimited data recordings to a PC.

6. Технічне обслуговування

6.1 Очищення

Clean the exterior of the multimeter with a soft, damp cloth. Do not use abrasive cleaners or solvents. The device is dust and water resistant (IP 54 compliant), but avoid submerging it in liquids.

6.2 Догляд за акумулятором

Regularly charge the 9-volt rechargeable battery. If the meter will not be used for an extended period, it is advisable to fully charge the battery and store the meter in a cool, dry place. Be aware that the OLED display can consume significant power, potentially leading to shorter battery life compared to meters without OLED displays. Monitor the battery indicator and charge as needed.

7. Вирішення проблем

7.1 Display Not Working or Dim

If the OLED display is dim or not functioning, first check the battery charge level. A low battery can affect display performance. If the issue persists after charging, contact Keysight support. While OLED displays offer excellent clarity, some users have reported issues with display longevity over time.

7.2 Короткий термін служби батареї

The U1253B's OLED display and advanced features contribute to higher power consumption. If you experience unusually short battery life, ensure the battery is fully charged and consider carrying a spare or having charging facilities readily available. The 9-volt battery may not provide as long a runtime as other battery configurations found in simpler DMMs.

7.3 Неточні показники

Verify that the test leads are correctly connected and not damaged. Ensure the rotary dial is set to the appropriate function and range for the measurement. If measuring in noisy electrical environments, ensure the Low Pass Filter (LPF) is engaged if applicable. If inaccuracies persist, the device may require calibration or service.

8. Технічні характеристики

  • модель: U1253B
  • Дисплей: 4.5-Digit Organic LED (OLED)
  • роздільна здатність: 30,000 відліків
  • Точність змінного струму: 0.7%
  • Лічильник частоти: Integrated 20 MHz
  • Генератор сигналів: Programmable Square-Wave (selectable frequency and duty cycle)
  • Реєстрація даних: Internal memory for up to 200 readings
  • Захист навколишнього середовища: Dust and water resistant (IP 54 compliant)
  • Джерело живлення: Акумуляторна батарея 9 В

9. Гарантія та підтримка

For information regarding warranty coverage, technical support, or service, please refer to the official Keysight Technologies website or contact their customer service department directly. Ensure you have your product model number (U1253B) and purchase details available when seeking support.

Пов'язані документи - U1253B

попередньоview Keysight U1253B True RMS OLED Multimeter Quick Start Guide
Quick start guide for the Keysight U1253B True RMS OLED Multimeter, covering setup, features, and basic measurements like voltage, current, resistance, capacitance, temperature, frequency, and square wave output.
попередньоview Keysight U1253B True RMS OLED Multimeter User's and Service Guide
Comprehensive user and service guide for the Keysight U1253B True RMS OLED Multimeter, covering safety, environmental conditions, features, measurements, maintenance, and specifications.
попередньоview Keysight U1231A/U1232A/U1233A Handheld Multimeter Quick Start Guide
A quick start guide for Keysight U1231A, U1232A, and U1233A handheld multimeters, covering setup, operation, and basic measurements.
попередньоview Keysight Truevolt Series Digital Multimeter: Operation and Service Guide
Comprehensive guide for operating and servicing Keysight Truevolt Series Digital Multimeters, covering features, measurements, troubleshooting, and calibration.
попередньоview Keysight USB Modular Products and Systems Quick Start Guide
Learn how to install and configure Keysight's USB Modular Products and Systems with this comprehensive Quick Start Guide, covering essential setup steps and features for test and measurement applications.
попередньоview Keysight U1731C/U1732C/U1733C Handheld LCR Meter User's Guide
Comprehensive user's guide for the Keysight U1731C, U1732C, and U1733C Handheld LCR Meters. Learn about features, setup, measurements, and safety precautions for accurate component testing.