An image showing the Field Controls MG-1 Gas Draft Control Regulator, a circular metal device with a clear cover and a chain for adjustment.
This manual provides essential information for the safe and effective use of your Field Controls 6-inch MG-1 Gas Draft Control/Regulator. This device is designed to provide precise and accurate control of drafts in gas-fired heating systems, particularly in applications where higher draft levels are required than those managed by standard draft diverters.
Безпека перш за все: Installation of gas appliances and their components should only be performed by qualified and licensed professionals. Improper installation can lead to serious injury, property damage, or death. Always consult local codes and regulations.
The Field Controls MG-1 is designed for installation on the flue pipe of a gas appliance. Key dimensions for this model include:
Ensure the installation location provides adequate clearance for the regulator's operation and future maintenance. The device should be securely mounted to prevent movement or vibration.
The MG-1 Gas Draft Control/Regulator automatically adjusts to maintain a consistent draft in the flue, optimizing combustion efficiency and safety. It operates by opening or closing a damper to regulate the flow of combustion gases. This precise control is crucial for gas appliances that require specific draft conditions for optimal performance and to prevent issues such as incomplete combustion or excessive heat loss.
The regulator's design allows for fine-tuning of the draft, ensuring that the appliance operates within its specified parameters, even when external conditions (like wind or atmospheric pressure) fluctuate.
Regular inspection and maintenance are essential to ensure the continued safe and efficient operation of your Field Controls MG-1 Gas Draft Control/Regulator. It is recommended that a qualified technician perform annual inspections as part of your heating system's routine maintenance.
Do not attempt to lubricate or modify the internal components of the regulator unless specifically instructed by the manufacturer.
If you suspect an issue with your gas draft control, it is crucial to contact a qualified HVAC technician immediately. Attempting to diagnose or repair gas appliance components without proper training and tools can be dangerous.
Common indicators of a potential issue might include:
A technician can assess the draft conditions, inspect the regulator, and perform any necessary adjustments or replacements.
| Специфікація | Деталь |
|---|---|
| Виробник | Польові елементи керування |
| Номер деталі | 02724001 |
| Номер моделі товару | 6MG1 |
| Вага товару | 2.2 фунта |
| Розміри продукту | 6 x 3 x 6 дюймів |
| Включені компоненти | Gas Draft Control |
| ASIN | B00ICS1GUA |
| Дата першої доступності | 10 лютого 2014 р |
Specific warranty details for the Field Controls 6-inch MG-1 Gas Draft Control/Regulator are not provided in this document. Please refer to the product packaging or the official Field Controls webсайт для отримання найактуальнішої інформації про гарантію.
For technical assistance, installation questions, or service inquiries, please contact Field Controls directly or consult a qualified HVAC professional.
You can find more information about Field Controls products and support on their official website or by visiting their Фірмовий магазин Amazon.
![]() |
Схеми підключення систем нафтопродуктів Field Controls CK-61, 62, 63 Детальні схеми підключення для одиночних масляних систем Field Controls CK-61, 62 та 63, включаючи підключення силового вентиляційного отвору, індуктора тяги, первинного керування та трансформатора запалювання. |
![]() |
Керівництво з встановлення польових систем керування живленням PVG-100, PVG-300, PVG-600 This installation manual provides detailed instructions for the Field Controls Power Venter models PVG-100, PVG-300, and PVG-600. It covers unit specifications, sizing calculations, safety precautions, installation procedures, wiring diagrams, system checks, maintenance, and troubleshooting for HVAC applications. |
![]() |
Вентиляційний клапан живлення SWG/CV від Field Controls: встановлення, визначення розмірів та технічні характеристики Вичерпний посібник з вентиляційних блоків Field Controls SWG та ComboVent (CV), що охоплює характеристики продукту, визначення розмірів, встановлення, планування системи, зазори, комплекти керування, налаштування системи та обслуговування. Містить детальні характеристики та поради щодо усунення несправностей. |
![]() |
Камін Flue Sentinel Millivolt DampПосібник з встановлення | Польові елементи керування Інструкція з встановлення каміна Flue Sentinel Millivolt Fireplace Damper (серія FSM) від Field Controls. Охоплює технічні характеристики, розміри, процедури встановлення, схеми підключення, послідовність роботи, усунення несправностей та технічне обслуговування газових камінів. |
![]() |
Зволожувач повітря Field Controls S2000 та S2020 Power: Інструкція з встановлення та експлуатації Вичерпні інструкції з встановлення та посібник користувача для електронних парових зволожувачів повітря Field Controls S2000 (120 В змінного струму) та S2020 (240 В змінного струму). Дізнайтеся, як встановити, експлуатувати та обслуговувати пристрій для оптимальної роботи в системах примусової вентиляції. |
![]() |
Посібник користувача очищувача повітря Trio Plus | Польові елементи керування Вичерпний посібник користувача для очищувача повітря Field Controls Trio Plus, що охоплює безпеку, експлуатацію, технічне обслуговування, заміну фільтра, усунення несправностей та технічні характеристики. |