1. Продукт закінчивсяview
The Juniper Networks QFX5100-48S-AFI is a highly flexible, high-performance Layer 3 switch designed to provide the foundation for modern data centers. It supports cloud and Software-Defined Networking (SDN) adoption, enabling rapid deployment and delivery of applications. This switch is a universal building block for data center switching architectures, offering diverse deployment options including fabric, Layer 3, and spine and leaf configurations, allowing easy adaptation to changing requirements.

Малюнок 1: Спереду view of the Juniper Networks QFX5100-48S-AFI Layer 3 Switch, showing the numerous SFP+ ports.
2. Налаштування та встановлення
This section provides general guidelines for setting up your Juniper Networks QFX5100-48S-AFI switch. For detailed rack mounting and cabling instructions, please refer to the official Juniper Networks documentation.
2.1 Фізичне встановлення
- Монтаж в стійку: The QFX5100-48S-AFI is designed for rack-mounting. Ensure proper rack space and ventilation.
- Підключення живлення: Connect the power cords to the power supply units at the rear of the switch. This unit may have more than one power supply cord. CAUTION: Disconnect all power supply cords before servicing to avoid electric shock.
- Network Cabling: Connect your network cables (fiber optic SFP+ transceivers) to the front panel ports.

Малюнок 2: Задня частина view of the switch, highlighting the modular power supply units and fan modules. Note the "AIR OUT" labels on the fan modules, indicating airflow direction.

Figure 3: Close-up of the AC input warning label, indicating 100-240V~50-60Hz 4.5-2A input and a caution about disconnecting all power cords before servicing.
3. Керування комутатором
Once the switch is physically installed and powered on, it will begin its boot sequence. The front panel provides indicators for system status and port activity.
3.1 Індикатори на передній панелі
- Світлодіоди стану системи: Monitor the ALM (Alarm), SYS (System), and MST (Master) LEDs for overall device health.
- Port Activity LEDs: Each SFP+ port has an associated LED that indicates link status and activity. A green light typically signifies an active link.

Малюнок 4: Сторона view of the switch, showing mounting brackets and chassis design.

Рисунок 5: Протилежна сторона view of the switch, providing another perspective of its physical dimensions.
3.2 Інтерфейси управління
The switch can be managed via its console port (CON), out-of-band management Ethernet port (C0), or in-band management through a configured network interface. The USB port can be used for software upgrades or configuration backups.

Figure 6: Close-up of the product label, showing SKU: QFX5100-48S-AFI, Serial Number (SN): TA3716510011, Part Number (PN): 650-064381 REV: 09, Manufacturing Date: 20161226, and MAC Address: 08:B2:58:C4:E0:00.

Figure 7: Close-up of the regulatory compliance label, indicating compliance with FCC Part 15, CE, UL, and other certifications. It also states "ASSEMBLED IN CHINA".
4. Технічне обслуговування
Regular maintenance ensures optimal performance and longevity of your QFX5100-48S-AFI switch.
- Прибирання: Keep the switch and its surroundings clean and free of dust. Use a soft, dry cloth for external cleaning. Do not use liquid cleaners.
- Потік повітря: Ensure that the air intake and exhaust vents are unobstructed to maintain proper cooling. The fan modules are designed for specific airflow directions (e.g., "AIR OUT").
- Оновлення прошивки: Періодично перевіряйте службу підтримки Juniper Networks website for the latest firmware updates to ensure security and performance enhancements.
- Заміна компонентів: Power supply units and fan modules are hot-swappable. Refer to the official documentation for safe replacement procedures.
5. Вирішення проблем
This section covers common issues and their potential solutions.
| проблема | Можлива причина | Рішення |
|---|---|---|
| Перемикач не вмикається. | Power cords not connected or power supply failure. | Ensure all power cords are securely connected. Check power outlets. Verify power supply unit status LEDs. |
| Світлодіод порту вимкнений. | No link, faulty cable, or incorrect transceiver. | Check cable connection at both ends. Replace cable. Verify transceiver compatibility and proper insertion. Check remote device status. |
| System Alarm LED (ALM) is lit. | Hardware fault, temperature issue, or power issue. | Check system logs for specific error messages. Ensure proper ventilation. Verify power supply status. Contact Juniper Networks support if the issue persists. |
6. Технічні характеристики
| Особливість | Деталь |
|---|---|
| Номер моделі | QFX5100-48S-AFI |
| Бренд | Juniper Networks |
| Тип перемикача | Керований |
| Кількість портів | 48 (SFP+) |
| Слоти розширення | 54 |
| Тип інтерфейсу | PoE, SFP |
| Матеріал корпусу | метал |
| Колір | Сірий |
| Вага товару | 21.8 фунта |
| Розміри упаковки | 36 x 24 x 12 дюймів |
| Виробник | Juniper Networks, Inc. |
| Дата першої доступності | 24 грудня 2013 р |
| UPC | 832938068032 |
7. Гарантія та підтримка
Щоб отримати детальну інформацію про гарантію та технічну підтримку, зверніться до офіційного веб-сайту Juniper Networks. website or contact their customer service. Keep your product's serial number (found on the product label, e.g., TA3716510011) readily available when seeking support.
You can find more information and support resources at the official Juniper Networks webсайт.