Левітон 1254-R

Левітон 15 Amp 125 Volt Industrial Grade 4-in-1 Receptacle (Model 1254-R) Instruction Manual

Модель: 1254-R

1. Вступ

This manual provides detailed instructions for the safe installation, operation, and maintenance of the Leviton 15 Amp, 125 Volt, Industrial Series Extra Heavy Duty Grade, 4-In-1 Receptacle, Model 1254-R. This device is designed for demanding environments requiring high-abuse tolerance, such as healthcare facilities, manufacturing plants, and educational institutions. It features four outlets in a single-gang footprint, offering increased power access without requiring larger electrical boxes.

2. Інформація про безпеку

УВАГА: To avoid fire, shock, or death, turn off power at the circuit breaker or fuse box and test that power is off before wiring. All wiring must be in accordance with national and local electrical codes. If you are unsure about any part of these instructions, consult a qualified electrician.

3. Вміст упаковки

The package for the Leviton 1254-R 4-in-1 Receptacle typically includes:

4. Технічні характеристики

ОсобливістьДеталь
Номер моделі1254-Р
Ampераж15 Amp
томtage125 Вольт
ОцінкаIndustrial Series Extra Heavy Duty Grade
Тип ємності4-In-1, Straight Blade, Grounding
КолірЧервоний
матеріалThermoplastic Nylon (Cover and Body)
Параметри електропроводкиBack and Side Wiring
КонтактиExtra Heavy-Duty, T-type triple-wipe bronze
РозміриПриблизно 8 x 8 x 8 дюймів (розміри виробу)
вагаПриблизно 6.4 унції

5. Монтаж

Follow these steps for proper installation of your Leviton 4-in-1 Receptacle. If you are not familiar with electrical wiring, consult a qualified electrician.

  1. Вимкніть живлення: Знайдіть автоматичний вимикач або запобіжник, який керує розеткою, де ви плануєте встановити розетку. Вимкніть її. Переконайтеся, що живлення вимкнено за допомогою регулятора гучності.tagтестер.
  2. Видаліть стару розетку (якщо застосовується): Unscrew the wall plate and then the mounting screws holding the existing receptacle in the electrical box. Carefully pull the old receptacle out of the box.
  3. Від'єднайте дроти: Від’єднайте дроти від старої розетки. Зверніть увагу, який провід був підключений до якої клеми (під напругою, нуль, заземлення).
  4. Підготуйте дроти: Strip approximately 1/2 inch of insulation from the ends of the wires if necessary. Ensure the wire ends are clean and straight.
  5. Підключіть дроти до нової розетки:
    • Підключіть HOT (Black or Red) дріт до Латунь клемні гвинти.
    • Підключіть НЕЙТРАЛЬНИЙ (білий) дріт до Срібло клемні гвинти.
    • Підключіть GROUND (Green or Bare Copper) дріт до Зелений гвинт заземлення.

    This receptacle supports both back-wiring (inserting wires into holes on the back and tightening screws) and side-wiring (wrapping wires around terminal screws). Ensure connections are tight and no bare wire is exposed outside the terminals.

    Leviton 1254-R 4-in-1 Receptacle, Red

    Зображення 5.1: спереду view of the Leviton 1254-R 4-in-1 Receptacle in Red. This image shows the four outlets and the robust construction.

    Close-up of receptacle wiring terminals

    Зображення 5.2: Крупний план view of a Leviton receptacle's wiring terminals, illustrating the side-wiring option and the grounding screw.

  6. Розетка для кріплення: Carefully push the wired receptacle back into the electrical box. Secure it with the provided mounting screws.
  7. Встановити настінну пластину: Прикріпіть настінну пластину над розеткою.
  8. Відновлення живлення: Turn the circuit breaker or fuse back ON.
  9. Тест: Plug a device into each of the four outlets to ensure proper function.

The 1254-R features an interlocking thermoplastic nylon cover and body for enhanced durability and a nickel-plated brass strap with integral ground contacts for reliable grounding. The permanent "Green Dot" marking on the face indicates its hospital/industrial grade compliance.

Close-up of receptacle with green dot marking

Image 5.3: Detail showing the "Green Dot" marking, signifying the industrial/hospital grade rating of the receptacle.

6. Операція

The Leviton 1254-R 4-in-1 Receptacle operates like any standard electrical outlet. Simply insert the plug of your electrical device into one of the four available receptacles. Ensure the plug is fully inserted for a secure connection. The extra heavy-duty, T-type triple-wipe bronze contacts provide maximum performance and a strong grip on cords.

7. Технічне обслуговування

This industrial-grade receptacle requires minimal maintenance. Periodically inspect the receptacle for any signs of damage, such as cracks, discoloration, or loose connections. If any damage is observed, turn off power at the circuit breaker and replace the receptacle immediately. Clean the surface with a soft, dry cloth. Do not use abrasive cleaners or solvents.

8. Вирішення проблем

проблемаМожлива причинаРішення
На розетці немає живлення.Спрацював автоматичний вимикач або перегорів запобіжник. Нещільне з'єднання проводки.Check and reset the circuit breaker or replace the fuse. Turn off power and inspect wiring connections for tightness.
Device plug feels loose in the outlet.Worn contacts (unlikely for new industrial grade). Incorrect plug type.Ensure the plug is fully inserted. If the issue persists, and the receptacle is old, consider replacement. Verify plug compatibility.
Receptacle is warm to the touch.Overload on the circuit. Loose wiring connection.Disconnect some devices to reduce load. Turn off power and check wiring connections. If warming persists, consult an electrician.

9. Інформація про гарантію

Leviton products are backed by a limited warranty. For specific warranty terms and conditions applicable to the 1254-R receptacle, please refer to the warranty documentation included with your purchase or visit the official Leviton webсайт. Зберігайте чек про покупку для гарантійних претензій.

10. Підтримка

For technical assistance, product information, or customer support, please visit the official Leviton website or contact their customer service department. Contact details can typically be found on the product packaging or the Leviton webсайт.

Левітон Webсайт: www.leviton.com

Пов'язані документи - 1254-Р

попередньоview Інструкція з встановлення та експлуатації розетки Leviton GFCI з USB-портами
Вичерпний посібник з встановлення та експлуатації розеток Leviton GFCI з USB-портами, включаючи інструкції з підключення, попередження щодо безпеки, процедури тестування та інформацію про гарантію.
попередньоview Встановлення та тестування розетки Leviton Smart GFCI: вичерпний посібник
Покрокові інструкції з встановлення та тестування розеток Leviton Smart GFCI (моделі D2GF1, D2GF2). Дізнайтеся про функціональність GFCI, підключення, усунення несправностей та запобіжні заходи.
попередньоview Керівництво з встановлення та тестування розеток Leviton SmartlockPro GFCI
Вичерпний посібник із встановлення та тестування розеток Leviton SmartlockPro із захистом від замикання на землю (GFCI). Охоплює запобіжні заходи, підключення, усунення несправностей та характеристики виробу.
попередньоview Керівництво з встановлення та тестування розеток GFCI Leviton
Вичерпний посібник з встановлення та тестування розетки Leviton SmartLock Pro GFCI, включаючи інструкції з підключення, запобіжні заходи та поради щодо усунення несправностей.
попередньоview Керівництво з встановлення розетки GFCI для монтажу на DIN-рейку Leviton GFNT1-DIN/GFNT2-DIN
Вичерпний посібник з встановлення та тестування розеток GFCI Leviton GFNT1-DIN та GFNT2-DIN для монтажу на DIN-рейку, включаючи інструкції з підключення, запобіжні заходи та усунення несправностей.
попередньоview Leviton Smart Wallbox Sensors: Elevate Your Sensing Control Options
Discover Leviton Smart Wallbox Sensors for commercial applications, offering occupancy/vacancy sensing, dimming, switching, energy savings, and code compliance for offices, meeting rooms, and lobbies. Learn about key features and benefits.