Yellow Jacket 42006

Yellow Jacket 42006 Series 41 Manifold Instruction Manual

Model: 42006 | For R-22, R-134A, R-404A Refrigerants

1. Вступ

This manual provides essential instructions for the safe and effective operation, setup, maintenance, and troubleshooting of your Yellow Jacket 42006 Series 41 Manifold. Please read this manual thoroughly before using the product to ensure proper function and to prevent damage or injury.

The Yellow Jacket 42006 Series 41 Manifold is designed for testing and charging refrigeration and air conditioning systems using R-22, R-134A, and R-404A refrigerants. It features durable construction and precise gauges for accurate readings.

2. Інформація про безпеку

WARNING: Always wear appropriate personal protective equipment (PPE), including safety glasses and gloves, when working with refrigerants and refrigeration systems.

3. Вміст упаковки

Перевірте наявність усіх предметів у вашій упаковці:

Yellow Jacket 42006 Series 41 Manifold with gauges and hoses

малюнок 1: Yellow Jacket 42006 Series 41 Manifold with attached color-coded hoses. The manifold body is brass, featuring two large 3-1/8 inch gauges (blue for low pressure, red for high pressure) and three ports for hose connections. The hoses are yellow, red, and blue, coiled around the manifold, with brass fittings at their ends.

4. Особливості продукту

The Yellow Jacket 42006 Series 41 Manifold offers the following key features:

5. Налаштування

Before initial use, inspect all components for any signs of damage. Ensure all connections are clean and free of debris.

5.1 Підключення шлангів

  1. Identify the three ports on the manifold:
    • Low Side (Blue): Typically on the left, connects to the low-pressure side of the system.
    • High Side (Red): Typically on the right, connects to the high-pressure side of the system.
    • Service/Vacuum (Yellow): Center port, connects to the vacuum pump, refrigerant tank, or recovery unit.
  2. Connect the blue hose to the low-side port on the manifold.
  3. Connect the red hose to the high-side port on the manifold.
  4. Connect the yellow hose to the service/vacuum port on the manifold.
  5. Hand-tighten all connections, then use a wrench to ensure a secure, leak-free seal. Do not overtighten.

5.2 Gauge Calibration Check

Before each use, ensure the gauge needles rest at zero when the manifold is not connected to a pressurized system. If a gauge does not read zero, it may require calibration or service. Refer to the maintenance section for more details.

6. Інструкція з експлуатації

This section outlines general procedures for using the manifold. Specific procedures may vary based on the task (e.g., vacuuming, charging, testing).

6.1 Connecting to a System

  1. Ensure both manifold valves are closed (turned clockwise until snug).
  2. Connect the free end of the blue hose to the low-pressure service port of the refrigeration system.
  3. Connect the free end of the red hose to the high-pressure service port of the refrigeration system.
  4. Connect the free end of the yellow hose to your vacuum pump, refrigerant tank, or recovery unit, depending on the task.
  5. Hand-tighten all connections, then use a wrench to ensure a secure seal.

6.2 Reading Gauges

The manifold features two gauges:

Read the pressure value corresponding to the refrigerant type being used on the appropriate scale.

6.3 Vacuuming a System

  1. Connect the manifold to the system and vacuum pump as described in Section 6.1.
  2. Open both the low-side and high-side manifold valves (turn counter-clockwise).
  3. Запустіть вакуумний насос.
  4. Monitor the low-side gauge. Continue vacuuming until the desired vacuum level is achieved (typically indicated by a deep vacuum gauge, not the manifold gauge).
  5. Once vacuum is achieved, close both manifold valves and turn off the vacuum pump.
  6. Observe the low-side gauge for any rise in pressure, which would indicate a leak.

6.4 Charging a System

  1. Ensure the system is under vacuum and leak-free.
  2. Connect the yellow hose to the refrigerant tank.
  3. Purge the yellow hose by slightly opening the refrigerant tank valve and then briefly loosening the yellow hose connection at the manifold to release any air, then retighten.
  4. Відкрийте клапан бака з холодоагентом.
  5. Slowly open the low-side manifold valve to allow refrigerant to enter the system. Monitor the low-side gauge.
  6. Charge the system according to the manufacturer's specifications. Close the low-side valve when the desired charge is reached.
  7. Close the refrigerant tank valve.
  8. Обережно від'єднуйте шланги, забезпечуючи мінімальний витік холодоагенту.

7. Технічне обслуговування

7.1 Очищення

Wipe down the manifold and hoses with a clean, damp cloth after each use. Avoid using harsh chemicals or solvents that could damage the gauges or hose material.

7.2 Зберігання

Store the manifold in a clean, dry place, away from direct sunlight and extreme temperatures. Keep the hoses coiled neatly to prevent kinking or damage. Use the integrated hook for convenient storage.

7.3 Калібрування манометра

If a gauge consistently reads off-zero when unpressurized, it may require recalibration or replacement. Yellow Jacket gauges are factory calibrated. For significant discrepancies, contact a qualified service technician or Yellow Jacket customer support.

7.4 O-Ring and Seat Replacement

Periodically inspect the O-rings and valve seats for wear or damage. Worn components can lead to leaks and inaccurate readings. Replacement kits are available from Yellow Jacket distributors.

8. Вирішення проблем

проблемаМожлива причинаРішення
Gauge reads incorrectly (not zero when unpressurized)Gauge out of calibration or damaged.Contact Yellow Jacket support for service or replacement.
Витік холодоагенту з з'єднаньНещільні з'єднання, зношені кільця ущільнювачів або пошкоджені фітинги шлангів.Затягніть з'єднання. Перевірте та замініть кільця ущільнювачів або шланги, якщо вони пошкоджені.
Slow or restricted flowKinked hose, debris in manifold/hoses, or partially closed valve.Check hoses for kinks. Inspect for debris. Ensure valves are fully open when required.

9. Технічні характеристики

10. Гарантія та підтримка

For warranty information, technical support, or service inquiries, please contact Yellow Jacket customer service or visit their official webсайт. Зберігайте чек про покупку як підтвердження покупки.

Виробник: Fotronic Corporation

Webсайт: www.yellowjacket.com (This is a placeholder link, verify the actual manufacturer webсайт.)

Пов'язані документи - 42006

попередньоview Машини для відновлення холодоагентів Yellow Jacket RecoverXLT та RecoverX
Вичерпний посібник з установок для рекуперації холодоагенту RecoverXLT та RecoverX від Yellow Jacket, що містить детальний опис функцій, специфікацій, принципу роботи та порівняльні таблиці для фахівців з опалення, вентиляції та кондиціонування повітря.
попередньоview Yellow Jacket HVAC/R Charging Systems & Diagnostic Tools Catalog
This catalog showcases Yellow Jacket's comprehensive range of HVAC/R charging systems and diagnostic tools, including the YJACK™ Series wireless sensors, P51 TITAN® Digital Manifolds, ManTooth® Wireless Gauges, and various BRUTE II® and Series 41 manifolds. The products are designed for accurate measurements, efficient system analysis, and enhanced user experience in HVAC/R applications.
попередньоview Yellow Jacket TitanMax Digital Manifold - Features and Specifications
Explore the Yellow Jacket TitanMax Digital Manifold, a 4-valve system offering fast and accurate measurements for refrigeration and A/C systems. Features include a high-resolution touchscreen, wireless connectivity via Bluetooth to YJACK VIEW® and measureQuick® apps, on-board data logging, and compatibility with A2L refrigerants.
попередньоview YELLOW JACKET YJACK® Series Bluetooth® Sensing Technology User Manual & Product Guide Rev. C
This comprehensive user manual and product guide for the YELLOW JACKET® YJACK® Series Bluetooth® Sensing devices details their advanced features, integration with the P51-870 TITAN® Digital Manifold and YJACK VIEW® app, and specifications for HVAC/R professionals.
попередньоview YELLOW JACKET TITANMAX™ User Manual
Comprehensive user manual for the YELLOW JACKET TITANMAX™ digital manifold, detailing its features, operation, settings, maintenance, and troubleshooting for HVAC professionals. Includes model numbers P/N 40880, 40881, 40885, 40887.
попередньоview Yellow Jacket TITANMAX™ Digital Manifold Quick Start Guide
Quick start guide for the Yellow Jacket TITANMAX™ Digital Manifold, covering setup, connections, main features, and settings for HVAC technicians. Learn how to power on, connect probes, navigate menus, and configure settings for pressure, temperature, vacuum, and psychrometric measurements.