BSIDE O2

BSIDE O2 Handheld Oscilloscope + Signal Generator User Manual

Model: O2 | Brand: BSIDE

1. Вступ

The BSIDE O2 is a versatile handheld device combining a dual-channel oscilloscope and a signal generator, designed for electrical engineers, hobbyists, and students. Featuring a 3.98-inch resistive touch screen, it offers intuitive operation and a compact design for portability. This manual provides detailed instructions for safe and effective use of your BSIDE O2 device.

2. Особливості продукту

  • Dual-channel oscilloscope with 50MHz bandwidth.
  • S в режимі реального часуampling rate of 250MSa/s.
  • Integrated signal generator with 7 adjustable waveform types.
  • 3.98-inch TFT large-screen LCD display with 488*320px resolution.
  • Resistive touch screen for easy navigation and parameter adjustment.
  • Compact and portable design (170.0*80.9*23.9mm).
  • Вбудований літій-іонний акумулятор ємністю 3000 мАг.
  • 128kb record length.
  • USB Type-C port for data transfer and charging.
  • Certified with CE, RoHS, FCC standards.
BSIDE O2 Handheld Oscilloscope and Signal Generator with key features highlighted
Figure 2.1: BSIDE O2 Handheld Oscilloscope and Signal Generator with key features.
Детальний view of BSIDE O2 features including hardening material, silicone sheath, function wheel, signal generator output, and Type-C port.
Figure 2.2: Detailed features of the BSIDE O2, including construction materials and ports.

3. Вміст упаковки

Будь ласка, перевірте вміст упаковки після отримання. Якщо будь-які предмети відсутні або пошкоджені, негайно зверніться до продавця.

ПунктКількість
Dual-channel oscilloscope-O2 host1
10X Oscilloscope Probe1
Red and Black Alligator Clip Probe1
USB-кабель Type-C1
Сумка для зберігання з етиленвінілацетату1
Oscilloscope Manual1
Сертифікат на продукцію1
Image showing the BSIDE O2 device and all its accessories, including probes, USB cable, and storage bag.
Figure 3.1: BSIDE O2 device and included accessories.

4. Технічні характеристики

АтрибутЗначення
Торгова маркаBSIDE
Номер моделіO2
Ширина стрічки50 МГц
Реальний час Sampлінг -курс250MSa / с
Цифрові канали2
Роздільна здатність дисплея488 * 320px
Розмір дисплея3.98 Inches (TFT LCD)
Довжина запису128 кб
Батарея в комплектіYes (3000mAh lithium battery)
АтестаціяCE, RoHS, FCC
Матеріали для самостійного виготовленняЕлектричний
ПоходженняМатериковий Китай
Розміри (Д*Ш*В)170.0*80.9*23.9 мм
вага0.533 кг
Comparison table of BSIDE-O2 and BSIDE-OT2 Mini Oscilloscope, highlighting specifications like bandwidth, sampling rate, channels, display, battery, and touch features.
Figure 4.1: Comparison of BSIDE-O2 with a mini oscilloscope model.

5. Інформація про безпеку

Будь ласка, прочитайте та зрозумійте всі інструкції з безпеки перед використанням пристрою. Недотримання цих інструкцій може призвести до ураження електричним струмом, пожежі або пошкодження пристрою.

  • Завжди використовуйте правильний томtage and current settings for your measurements.
  • Не піддавайте пристрій дії вологи або екстремальних температур.
  • Ensure probes are properly connected and insulated before making measurements.
  • Avoid touching exposed wires or components while the device is powered on.
  • Do not attempt to repair or modify the device yourself. Refer to qualified service personnel.
  • Тримайте пристрій подалі від сильних електромагнітних полів.

6. Налаштування

6.1 Зарядка пристрою

The BSIDE O2 comes with a built-in rechargeable lithium battery. Use the provided USB Type-C cable to charge the device. Connect one end of the cable to the device's Type-C port and the other end to a standard USB power adapter (not included) or a computer's USB port. The charging indicator will show the charging status.

6.2 Підключення зондів

  1. **Oscilloscope Probe (10X):** Connect the BNC connector of the oscilloscope probe to the OSC 1 or OSC 2 input port on the top of the device. Ensure it is securely twisted into place.
  2. **Alligator Clip Probe:** For signal generation, connect the red and black alligator clip probe to the 'OUTPUT' port on the side of the device.

6.3 Увімкнення/вимкнення

Press and hold the power button (usually located on the side or front panel) for a few seconds to turn the device on or off.

Close-up of the BSIDE O2 touch screen interface showing waveform display and control options.
Figure 6.1: Touch screen interface of the BSIDE O2.

7. Інструкція з експлуатації

7.1 Основна навігація

The device features a resistive touch screen and a function wheel for navigation. Use your finger or a stylus to interact with the touch screen menus and adjust settings. The function wheel can be used for fine adjustments or menu selection depending on the active mode.

7.2 Режим осцилографа

The BSIDE O2 operates as a dual-channel oscilloscope. You can select between Channel 1 (CH1) and Channel 2 (CH2) inputs.

  1. **Channel Selection:** Tap 'OSC 1' or 'OSC 2' on the screen to select the active channel.
  2. **Coupling (AC/DC):** Tap the coupling setting (e.g., 'ACx1', 'DCx10') to switch between AC and DC coupling modes.
  3. ** Випtage Scale:** Adjust the vertical scale (Volts/Div) by tapping the voltage display or using the function wheel.
  4. **Time Base:** Adjust the horizontal scale (Time/Div) by tapping the time display or using the function wheel.
  5. **Trigger Settings:** Tap 'TRIGGER' to access trigger options. You can set the trigger level, edge (rising/falling), and mode (Auto, Normal, Single).
  6. **Measurements:** The device automatically displays key waveform parameters such as Vpp (Peak-to-Peak Voltage), Vmax (Максимальний об'ємtage), Vmin (мінімальний об'ємtage), Vavg (Середній об'ємtage), RMS (Root Mean Square), Duty Cycle, and Frequency.
Video 7.1: Demonstration of connecting probes and observing waveforms on the BSIDE O2 oscilloscope.

8. Signal Generator Function

The integrated signal generator can produce various waveforms for testing and calibration purposes.

  1. **Access Signal Generator:** Navigate to the signal generator interface (refer to the device's on-screen menu for specific access).
  2. **Select Waveform:** Choose from 7 types of signal waveforms, including Sine, Square, Tunable Pulse, Triangular, Positive Sawtooth, Irregular Noise, Positive Full Wave, Negative Full Wave, Multi-frequency Waves, Banner Waveform, Lorentz Pulse, Multi-frequency Tone, Trapezoidal Pulses, Zink Pulse, Positive Half-Wave, Negative Half-Wave, Electrocardiogram, and Gaussian White Noise.
  3. **Adjust Parameters:** Set the desired amplitude, frequency, and duty cycle using the touch screen controls or the function wheel.
  4. **Output Signal:** Connect the alligator clip probe to the 'OUTPUT' port and to your circuit under test.
Image showing the BSIDE O2 device generating a signal, with a mini oscilloscope displaying the output waveform.
Figure 8.1: BSIDE O2 functioning as a signal generator.
Screen display showing various waveform types supported by the signal generator, including sine, square, triangular, and pulse waves.
Малюнок 8.2: Впрamples of multiple waveforms supported by the signal generator.

9. Передача даних

The BSIDE O2 allows for easy data management and secondary analysis by connecting to a PC via a USB cable.

  1. Підключіть пристрій до комп’ютера за допомогою наданого кабелю USB Type-C.
  2. Пристрій має відображатися на вашому комп’ютері як знімний носій інформації.
  3. You can then transfer recorded waveform data for further analysis using compatible software.
BSIDE O2 connected to a laptop via USB cable, showing waveform data being managed on the computer screen.
Figure 9.1: Data transfer from BSIDE O2 to a PC.

10. Технічне обслуговування

  • **Cleaning:** Use a soft, dry cloth to clean the device. Do not use abrasive cleaners or solvents.
  • **Storage:** Store the device in a cool, dry place, away from direct sunlight and extreme temperatures. Use the provided EVA storage bag for protection.
  • **Battery Care:** To prolong battery life, avoid fully discharging the battery frequently. Charge the device regularly, even if not in use for extended periods.
  • **Probe Care:** Handle probes carefully. Do not bend or twist the cables excessively. Inspect probes for damage before each use.

11. Вирішення проблем

  • **Device not powering on:** Ensure the battery is charged. Connect the device to a power source using the USB Type-C cable and try again.
  • **No waveform displayed:** Check if probes are correctly connected to the input channels. Verify the input signal is within the device's measurement range. Adjust voltage and time scales. Check trigger settings.
  • **Inaccurate readings:** Ensure probes are properly calibrated (if applicable) and that the correct probe attenuation (e.g., 1X, 10X) is selected on both the probe and the device.
  • **Touch screen unresponsive:** Try restarting the device. Ensure the screen is clean and dry.
  • **Signal generator not outputting:** Check if the alligator clip probe is correctly connected to the 'OUTPUT' port. Verify the signal generator settings (waveform, amplitude, frequency) are configured.

12. Поради користувача

  • For quick measurements, utilize the 'AUTO' function to automatically adjust the display settings.
  • Familiarize yourself with the function wheel for precise adjustments, especially when fine-tuning waveform parameters.
  • Regularly back up your recorded data to a computer to prevent loss.
  • При вимірюванні високої обtages, always use the 10X attenuation setting on your oscilloscope probe and ensure it is correctly set on the device to prevent damage and ensure safety.

13. Гарантія та підтримка

For warranty information, technical support, or service inquiries, please refer to the product certificate included in your package or contact the BSIDE Tools Store directly. Keep your purchase receipt as proof of purchase.


BSIDE O2 Dual Channel Handheld Oscilloscope & Signal Generator - 50MHz CATII 400V

BSIDE O2 Dual Channel Handheld Oscilloscope & Signal Generator - 50MHz CATII 400V

1:14 • 720×1280 • демонстрація
BSIDE O2 50MHz Dual Channel Handheld Oscilloscope & Signal Generator Demo

BSIDE O2 50MHz Dual Channel Handheld Oscilloscope & Signal Generator Demo

1:14 • 720×1280 • демонстрація
BSIDE O2 Dual Channel Handheld Oscilloscope & Signal Generator Feature Demo

BSIDE O2 Dual Channel Handheld Oscilloscope & Signal Generator Feature Demo

0:56 • 720×720 • демонстрація_функції