1. Вступ
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Rellytech 9000 BTU Mini Split AC/Heating System. Please read it thoroughly before using the product and keep it for future reference. This system offers powerful cooling and heating, dehumidification, and fan-only modes for year-round comfort.
2. Інформація про безпеку
Загальні заходи безпеки
- Installation must be performed by professional personnel.
- Забезпечте належну вентиляцію як внутрішнього, так і зовнішнього блоків.
- Do not operate near open flames or combustible gases.
- Verify all connections for gas leakage after installation.
- Ensure the system is vacuumed to remove all air before refrigerant release.
- All electrical connections must be correct and reliably secured.
Заборонені зони встановлення
Avoid installing the unit in the following locations:
- Near heat or steam sources.
- Areas with smoke or oil.
- Locations with obstructions around the inlet and outlet of indoor and outdoor units.
- Areas with flammable, explosive, or corrosive gases.
3. Вміст упаковки
Your Rellytech Mini Split AC/Heating System comes in two boxes. Packages may arrive at different times.

Figure: Detailed package list for the Rellytech Mini Split AC/Heating System.
Box 1 (Indoor Unit & Accessories):
- Внутрішній блок
- Пульт дистанційного керування
- Батарейки AAA (x2)
- Посібник користувача
- Шаблон дужки
- Монтажна пластина
- Communication Cable (12.5ft)
- Кабель живлення (5.9 фута)
Box 2 (Outdoor Unit & Installation Kit):
- Зовнішній блок
- Пластиковий ремінь
- Connecting Pipes (9.84ft)
- Luting (Putty)
- Pipe Protection Ring (6.56ft)
- Drain Pipe (6.56ft)
- Screws (4.2*50 x 8)
- Якоря (x6)
4. Налаштування та встановлення
Proper installation is crucial for the optimal performance and longevity of your mini split system. It is highly recommended that installation be performed by a certified professional.
4.1 Встановлення внутрішнього блоку
- Приготування: Ensure the wall for the indoor unit is hard, flat, and firm to prevent vibration and noise. Remove the mounting bracket pre-installed on the back of the indoor unit.
- Розміщення монтажного кронштейна: Use the provided paper pattern/template to identify the exact location for the mounting bracket and drill screw holes. Insert expansion tubes for expansion screws and securely mount the bracket on the wall.
- Wall Hole for Pipes: Drill a wall hole with a hole punch, ensuring a certain angle of inclination (high on the inside, low on the outside) for proper drainage.
- Duct Board Removal: Confirm the direction of placing the air conditioning ducts. Use tools to remove the duct boards from the indoor unit.
- Зняти захисну плівку: Carefully remove the protective film from the surface of the indoor unit.
- Electrical Connections (Indoor Unit): Lift the cover and remove the two screws of the power cord and the internal screws holding the cord. Thread the 5.9ft communication cable through the hole on the back of the indoor unit. Unscrew the terminals and fix the wires according to their color in the corresponding positions. Secure the presser plate over the main cable and re-attach the cover.
- Pipe and Wire Wrapping: Line up all wires and pipes neatly. Turn them to the position of the corresponding holes and wrap them together with plastic tapes for insulation and protection.
- Монтаж внутрішнього блоку: Hang the indoor unit on the shelf. Run the pipes and wires through the previously punched holes and cover them with pipe protection rings inside and outside the walls. Plug any excess holes using putty.

Figure: Indoor unit mounting bracket installation.
4.2 Встановлення зовнішнього блоку
- Drain Pipe and Remaining Pipes: Leave out the drain pipe and tape off the remaining pipes, ensuring the drain pipe is positioned for proper water flow.
- Place Outdoor Unit: Place the outdoor unit in a suitable location (outside the wall bracket or on the ground). Note: The equipment stand/bracket will need to be purchased separately.
- Connect Refrigerant Pipes (Outdoor Unit): Connect the two pipes to the outdoor unit, ensuring the joints fit snugly and are tightened with a wrench.
- Electrical Connections (Outdoor Unit): Remove the 3 screws from the cover of the electrical box. Use a tool to open the two holes at the lower end of the cover. Pass the wires through the cover hole (usually the right-hand hole). Fix the 3 wires of the power cable one by one according to the color (ground, fire, zero). Secure the fixing plate. Fix the 4 wires of the communication cable one by one according to the color.
4.3 Vacuuming the System
- Unscrew Nuts: Unscrew the three nuts circled on the outdoor unit's refrigerant lines.
- Підключення вакуумного насоса: Connect the stop valve, charging hose manifold valve, and vacuum pump to the outdoor unit's service port.
- Вакуумувати: Vacuumize for at least 15 minutes. Make sure the value on the pressure gauge is ≤ -0.1MPa (-76cmHg / 500µm). Keep the pressure for 35 minutes after vacuumizing to ensure springback is ≤ 0.05MPa.
- Open Liquid Valve: Open the 1/4 liquid valve, then remove the charging hose.
- Open Gas Valves: Using an allen wrench, open all the liquid valves and gas valves, and finally retighten the three caps.
5. Інструкція з експлуатації
Your Rellytech Mini Split AC/Heating System offers multiple modes and features for personalized comfort, controllable via the included remote or smart app (if applicable).

Figure: 4-in-1 Multifunctional Design.
Режими роботи:
- Режим охолодження: Provides powerful 9,000 BTU cooling for areas up to 450 sq. ft.
- Режим нагріву: Delivers 9,000 BTU heating. Note: Heating function may be unavailable below -7°C (19.4°F) outdoor temperature.
- Режим вентилятора: Циркулює повітря без охолодження або нагріву.
- Режим осушення: Зменшує вологість повітря.
- Режим ECO: Optimizes energy use for both cooling and heating.
Ключові характеристики:
- Регульований потік повітря: 4 fan speeds (high/medium/low/Auto) and 90° vertical swing.
- Тиха робота: Operates at just 42dB for peaceful environments.
- Режим сну: Gradually adjusts temperature for comfort during sleep.
- Режим тиші: Disables beeping from the remote control.
- 24-годинний таймер: Allows you to program operation times.
- LED-off Function: Reduces light disturbance.

Figure: Remote Control with Full Functionality.
6. Технічне обслуговування
Regular maintenance ensures the efficiency and longevity of your mini split system.

Figure: Removable and Easy-to-Clean Air Filter.
- Очищення повітряного фільтра: The indoor unit features removable and easy-to-clean air filters. Regularly clean these filters to maintain optimal airflow and air quality.
- Зовнішній блок: Keep the outdoor unit free from obstructions and debris. Periodically clean the coils to ensure efficient heat exchange.
- Дренаж: Ensure the drainage pipe is clear and free-flowing to prevent water accumulation.
7. Вирішення проблем
If you encounter issues with your mini split system, refer to the following basic troubleshooting steps. For complex problems, contact a qualified technician.
- Пристрій не вмикається: Check the power supply and ensure the unit is properly plugged in. Verify that the circuit breaker has not tripped.
- Недостатнє охолодження/обігрів: Ensure air filters are clean. Check for any obstructions around the indoor or outdoor units. Verify that the temperature settings are correct.
- Незвичайні шуми: Minor noises during operation are normal. If you hear loud or unusual noises, turn off the unit and contact support.
- Витік води: Перевірте дренажну трубу на наявність засмічень або неправильного встановлення.
8. Технічні характеристики
| Особливість | Деталь |
|---|---|
| Бренд | Rellytech |
| Інформація про модель | CE0-1 |
| Вага товару | 66.4 фунта |
| Розміри продукту | 11.4 x 30.7 x 8.7 дюймів |
| Ефективність | High (19 SEER2, HSPF2 8.5) |
| Ємність | 9000 BTU Cooling & Heating (up to 450 sq. ft.) |
| Рівень шуму | 42 децибели |
| Тип установки | Спліт-система |
| Форм-фактор | Міні-спліт |
| Особливості | Fast Cooling, Heating & Cooling Function, Inverter Compressor, Remote Controlled, Sleep Mode |
| Колір | Білий |
| томtage | 115 вольт |
| Wattage | 1000 Вт |
| Тип матеріалу | пластик |
| Включені компоненти | Монтажний комплект, пульт дистанційного керування |
9. Гарантія та підтримка