ДБЖ OLTEANP-TK2000W

OLTEANP 2000W Sump Pump Battery Backup System Instruction Manual

Model: UPS-TK2000W | Brand: OLTEANP

1. Вступ

This manual provides comprehensive instructions for the safe installation, efficient operation, and proper maintenance of your OLTEANP 2000W Sump Pump Battery Backup System. This system is designed to provide uninterrupted power to your sump pump during electrical outages, ensuring your basement remains dry. Please read this manual thoroughly before installation and operation to ensure optimal performance and safety.

2. Інформація про безпеку

  • Always disconnect the system from all power sources before performing any maintenance or installation.
  • Забезпечте належну вентиляцію навколо пристрою, щоб запобігти перегріванню.
  • Не піддавайте пристрій впливу води, дощу або надмірної вологи.
  • Use appropriate personal protective equipment (PPE) during installation, especially when handling batteries.
  • Connect the system only to compatible battery types as specified in this manual.
  • Ensure all wiring connections are secure and correctly polarized to prevent electrical hazards.
  • Keep children and unauthorized personnel away from the system.

3. Вміст упаковки

Перевірте наявність усіх елементів в упаковці:

  • OLTEANP 2000W Sump Pump Battery Backup System (Main Unit)
  • Кабелі акумулятора (червоний та чорний)
  • Посібник користувача (цей документ)
  • Пульт дистанційного керування з РК-екраном
  • Монтажні аксесуари (гвинти, анкера)
  • Кабель живлення
  • Small Wrench (for terminals)
Система резервного живлення від насоса OLTEANP потужністю 2000 Вт та аксесуари в комплекті

Figure 3.1: The OLTEANP 2000W Sump Pump Battery Backup System with its remote control, battery cables, power cable, and small wrench.

4. Продукт закінчивсяview

The OLTEANP 2000W Sump Pump Battery Backup System integrates a pure sine wave inverter, a 25A battery charger, and an automatic transfer switch into one unit. It features multiple output ports and a remote LCD controller for monitoring.

4.1 Функції передньої панелі

  • 3 розетки змінного струму: For connecting your sump pump and other AC devices.
  • USB-порт (5 В/3.1 А): Для заряджання невеликих електронних пристроїв.
  • Type-C Port (30W): For faster charging of compatible devices.
  • Вхід для зарядки змінного струму: Connects to grid power for charging the battery and powering loads.
  • Battery Type Selection Switches (DIP Switches): Allows selection of battery chemistry (GEL, AGM/SLA, Flooded/Wet, LiFePO4).
  • Перемикач ON/OFF: Головний вимикач живлення інвертора.
  • Fault LED (Red): Indicates a system fault.
  • Світлодіод живлення (зелений): Indicates the system is powered on.
  • Charge Full LED (Green): Показує, що акумулятор повністю заряджений.
  • Remote Connection Port: For connecting the LCD remote controller.
  • Запобіжник: Захист від перевантаження по струму.
Детальний view of the AC side and DC side ports and controls on the OLTEANP 2000W Sump Pump Battery Backup System

Figure 4.1: Front and rear panel connections and indicators.

4.2 Remote Controller with LCD Screen

The remote controller provides real-time monitoring of the system's status, including battery voltage, вихід змінного струму обtage, power consumption, and fault indicators. This allows for convenient monitoring without direct access to the main unit.

LCD remote controller displaying battery status, DC input voltage, вихід змінного струму обtagе, і ватtage

Figure 4.2: The remote controller's LCD screen displaying operational parameters.

5. Налаштування та встановлення

The OLTEANP Sump Pump Battery Backup System is designed for easy installation with minimal wiring. Follow these steps carefully.

5.1 Встановлення пристрою

The unit can be placed flat on a stable surface or wall-mounted using the fixed holes on the side. Ensure the mounting location is dry, well-ventilated, and away from flammable materials. Use appropriate screws and anchors for your wall type.

5.2 Підключення батареї

  1. Ensure the main unit is OFF before connecting batteries.
  2. Підключіть червоний кабель акумулятора до позитивний (+) terminal of the battery and the позитивний (+) термінал на інверторі.
  3. Підключіть чорний кабель акумулятора до мінус (-) terminal of the battery and the мінус (-) термінал на інверторі.
  4. Tighten all connections securely using the provided wrench.
  5. Важливо: The system requires a 12V deep-cycle battery (Lithium, AGM, Flooded/Wet). Do not use non-deep-cycle batteries.

5.3 Вибір типу батареї

Before turning on the inverter, set the DIP switches on the unit to match your battery type. Refer to the table below:

Table showing DIP switch settings for different battery types: GEL, AGM/SLA, Flooded/Wet, LiFePO4

Figure 5.1: DIP switch settings for various battery chemistries.

5.4 Підключення вхідних та вихідних сигналів змінного струму

  1. Plug the provided power cable into the AC Charge Input port on the inverter.
  2. Plug the other end of the power cable into a standard 120V AC wall outlet.
  3. Plug your sump pump and other desired AC devices into the 3 AC Outlets on the inverter.
  4. For permanent installations, the L, N, PE terminals can be used for direct wiring to a breaker panel by a qualified electrician.
Diagram illustrating the two modes of operation: charging the battery from AC input and powering devices from the inverter

Figure 5.2: System diagram showing AC input, battery charging, and inverter output to a sump pump.

Illustration of the 2000W Sump Pump Battery Backup System powering multiple sump pumps

Figure 5.3: The 2000W system can power multiple sump pumps with a combined wattage under 2000W.

5.5 Відео з встановлення

Video 5.1: Official OLTEANP video demonstrating the Sump Pump Battery Backup System installation and operation.

6. Інструкція з експлуатації

Once installed, the system operates largely automatically. Here's how to use and monitor it.

6.1 Увімкнення/вимкнення

  • To power on the system, press the ON/OFF switch on the main unit. The green Power LED will illuminate.
  • Щоб вимкнути живлення, знову натисніть кнопку ON/OFF.

6.2 Автоматичне перемикання (функція ДБЖ)

When grid power is available, the system charges the connected battery and passes AC power directly to your connected devices. In the event of a power outage, the system automatically switches to battery power within 12 milliseconds, ensuring continuous operation of your sump pump. When grid power is restored, it automatically switches back to grid power and resumes charging the battery.

6.3 Monitoring with Remote Controller

The remote LCD controller provides essential information:

  • Рівень заряду батареї: Displays the current charge level of the connected battery.
  • Вхід постійного струму обtage: Показує об'єм батареїtage.
  • Вихід змінного струмуtage: Відображає вихідний обсягtage supplied to your devices.
  • Wattage: Показує поточне споживання енергії підключеними пристроями.
  • Сигналізація про несправності: The screen will flash and display relevant fault codes if an issue occurs.

6.4 Режими роботи

  • Режим зарядки: When grid power is present, the internal 25A charger replenishes the battery.
  • Режим інвертора: Під час влади оtage, the system converts DC battery power to AC power for your devices.

Video 6.1: Official OLTEANP video demonstrating the Pure Sine Wave Power Inverter with Charger in operation.

7. Технічне обслуговування

Regular maintenance ensures the longevity and reliable operation of your system.

  • Прибирання: Періодично очищуйте зовнішню частину пристрою сухою ганчіркою. Переконайтеся, що вентиляційні отвори вільні від пилу та сміття.
  • Перевірка батареї: Regularly check battery terminals for corrosion and ensure connections are tight. For lead-acid batteries, check electrolyte levels if applicable.
  • Тестування: Periodically test the system by temporarily disconnecting grid power to ensure the automatic switching function operates correctly.
  • Зберігання: Якщо пристрій зберігається протягом тривалого часу, переконайтеся, що акумулятор повністю заряджений, і від’єднайте його від інвертора. Зберігайте у прохолодному, сухому місці.

8. Вирішення проблем

Якщо у вас виникли проблеми, зверніться до наступних поширених проблем та способів їх вирішення:

проблемаМожлива причинаРішення
Немає вихідного живлення з розеток змінного струму.Unit is off, low battery, overload, fault condition.Ensure unit is ON. Check battery charge. Reduce load. Check remote controller for fault codes.
Акумулятор не заряджається.AC input disconnected, incorrect battery type setting, faulty battery.Verify AC input connection. Check DIP switch settings for battery type. Test battery.
Remote controller not displaying.Loose connection, unit is off.Ensure remote cable is securely connected. Verify main unit is powered on.
Система несподівано вимикається.Перевантаження, перегрів, низький рівень заряду батареїtagе., коротке замикання.Reduce connected load. Ensure adequate ventilation. Recharge battery. Check for short circuits in wiring.

For persistent issues not covered here, please contact OLTEANP customer support.

9. Технічні характеристики

ОсобливістьДеталь
Номер моделіДБЖ-TK2000W
Wattage2000 Вт
Вхідний об'ємtage (DC)12 вольт
Вихід змінного струмуPure Sine Wave, 120V AC
Зарядний пристрій25A (DC-AC Quick Charge)
матеріалНержавіюча сталь
Вага товару15.47 фунта
Розміри упаковки20.2 x 12.9 x 6.6 дюймів
Стиль відображенняLCD (Remote Controller)
Включені компоненти2000W Sump Pump Battery Backup System, Battery Cables, User Manual, Remote Controller
Батарейки в комплектінемає
Потрібні батареїтак

10. Гарантія та підтримка

For warranty information and customer support, please refer to the documentation included with your purchase or visit the official OLTEANP webсайт. Зберігайте чек про покупку для гарантійних претензій.

© 2026 OLTEANP. Усі права захищено.