TOPTES TS-501B, TS-710

TopTes TS-501B Sound Level Meter and TS-710 Light Meter Instruction Manual

Comprehensive Guide for Environmental Monitoring

1. Вступ

This manual provides essential information for the safe and effective operation of your TopTes TS-501B Sound Level Meter and TS-710 Light Meter. These devices are designed for accurate environmental monitoring, allowing users to measure noise levels and light intensity in various settings. Please read this manual thoroughly before use and retain it for future reference.

2. Продукт закінчивсяview

The TopTes TS-501B Sound Level Meter and TS-710 Light Meter are a combined solution for environmental assessment. The TS-501B measures sound levels, while the TS-710 measures light intensity, ambient temperature, and humidity. Both devices feature a 2.25-inch backlit LCD screen for clear readings and user-friendly functions.

2.1 TS-501B Sound Level Meter

The TS-501B is equipped with a 1/2 inch electric condenser microphone for precise sound measurement. It offers A/C weighting options to analyze sound based on human ear perception (A-weighting) or for general noise analysis (C-weighting). The measurement range is 30 to 130 dB.

TopTes TS-501B Sound Level Meter displaying A-weighting measurement

малюнок 1: TS-501B Sound Level Meter showing A-Weighting measurement. This mode measures sound levels as perceived by the human ear, typically ranging from 30 to 130 dBA.

TopTes TS-501B Sound Level Meter displaying C-weighting measurement

малюнок 2: TS-501B Sound Level Meter showing C-Weighting measurement. This mode is suitable for general noise analysis, with a range of 30 to 130 dBC.

Close-up of the TS-501B's 1/2 inch electric condenser microphone with windshield ball

малюнок 3: Крупним планом view of the TS-501B's 1/2 inch Electric Condenser Microphone, protected by a windshield ball for high precision measurements.

2.2 TS-710 Light Meter

The TS-710 features a 180° rotating sensor for flexible light measurement from various directions. It measures light intensity from 0.1 to 200,000 lux (or 0.1 to 20,000 FC) and also provides readings for ambient temperature and humidity.

TopTes TS-710 Light Meter with its 180 degree rotating sensor

малюнок 4: TS-710 Light Meter demonstrating its 180° rotating sensor, allowing detection of light from all directions.

TopTes TS-710 Light Meter displaying readings on its 2.25 inch LCD screen

малюнок 5: TS-710 Light Meter with its easy-to-read 2.25-inch backlit LCD screen, showing current light, temperature, and humidity readings.

TopTes TS-710 Light Meter showing dual measurement units, LUX and Foot-Candle

малюнок 6: TS-710 Light Meter illustrating its capability for dual measurement units: LUX (0.1~200,000 LUX) and Foot-Candle (0.1~20,000 FC).

3. Інформація про безпеку

Observe the following safety precautions to prevent injury and avoid damage to the devices:

  • Do not attempt to open or modify the devices.
  • Keep the devices away from water, high humidity, and extreme temperatures.
  • Уникайте падіння пристроїв або сильних ударів.
  • Remove batteries if the devices will not be used for an extended period.
  • Утилізуйте батареї згідно з місцевими правилами.

4. Вміст упаковки

Перевірте наявність усіх елементів в упаковці:

  • 1 x TopTes TS-710 Light Meter
  • 1 x TopTes TS-501B Sound Level Meter
  • 2 x Carrying Cases (one for each device)
  • Батарейки типу AAA (попередньо встановлені або входять до комплекту)
  • Посібник користувача (цей документ)

5. Налаштування

5.1 Встановлення батареї

  1. Locate the battery compartment on the back of each device.
  2. Відкрийте кришку акумулятора.
  3. Вставте батарейки типу AAA, дотримуючись правильної полярності (+/-).
  4. Надійно закрийте кришку акумулятора.

5.2 Увімкнення/вимкнення

Натисніть потужність button (usually marked with a power symbol) on each device to turn it on. Press and hold the same button to turn it off. Both devices feature an automatic power-off function to conserve battery life after a period of inactivity.

6. Інструкція з експлуатації

6.1 General Functions (Both Devices)

  • Запис МАКС/МІН: Натисніть МАКС/МІН button to display the maximum or minimum recorded value during a measurement session. Press again to cycle through MAX, MIN, and current readings.
  • Утримання даних: Натисніть ТРИМАТИ button (or similar icon) to freeze the current reading on the display. Press again to release.
  • Підсвічування: Натисніть Підсвічування button (often marked with a light bulb symbol) to activate or deactivate the screen backlight for improved visibility in low-light conditions.
Illustration explaining MAX and MIN functions for measurement devices

малюнок 7: Explanation of MAX and MIN functions. MAX displays the highest value measured, while MIN displays the lowest value measured over a given period.

6.2 TS-501B Sound Level Meter Operation

  1. Увімкніть пристрій.
  2. Select Weighting (A/C): Натисніть кондиціонер button to switch between A-weighting (for human ear perception) and C-weighting (for general noise analysis).
  3. Select Response Time (FAST/SLOW): Натисніть F/S button to choose between Fast (125ms) or Slow (1s) response times, depending on the nature of the sound being measured.
  4. Point the microphone towards the sound source. The current sound level in decibels (dB) will be displayed.

6.3 TS-710 Light Meter Operation

  1. Увімкніть пристрій.
  2. Rotate Sensor: Adjust the 180° rotating sensor to face the light source directly or to capture ambient light as needed.
  3. Select Unit (LUX/FC): Натисніть ОДИНИЦЯ button to switch between Lux and Foot-Candle measurement units.
  4. The device will display the light intensity, ambient temperature, and humidity.

7. Технічне обслуговування

  • Прибирання: Use a soft, dry cloth to clean the device surfaces. Do not use abrasive cleaners or solvents. For the TS-710's light sensor, ensure it remains clean and free of dust for accurate readings.
  • Зберігання: Store the devices in their protective carrying cases in a cool, dry place when not in use. Avoid areas with high humidity or extreme temperatures.
  • Заміна батареї: Replace batteries promptly when the low battery indicator appears on the display to ensure continuous accurate operation.

8. Вирішення проблем

проблемаМожлива причинаРішення
Пристрій не включається.Низький заряд або розряджені батареї; неправильна полярність батарей.Замініть батарейки новими; переконайтеся в правильній полярності.
Неточні показання.Sensor obstruction (TS-710); microphone obstruction (TS-501B); environmental interference.Clean the sensor/microphone; ensure no obstructions; re-measure in a stable environment.
Дисплей тьмяний або порожній.Низький заряд батареї; підсвічування вимкнено.Replace batteries; press the backlight button.
Automatic power-off occurs too quickly.Default auto-off setting.This is a feature to conserve battery. Refer to specific device settings if adjustable (not all models allow adjustment).

9. Технічні характеристики

9.1 TS-501B Sound Level Meter

  • Діапазон вимірювання: від 30 до 130 дБ
  • Зважування: кондиціонер
  • Мікрофон: 1/2 inch Electric Condenser Microphone
  • Дисплей: 2.25-дюймовий РК-дисплей з підсвічуванням
  • функції: MAX/MIN recording, Data Hold, Auto Power-Off

9.2 TS-710 Light Meter

  • Light Measurement Range: 0.1 to 200,000 Lux / 0.1 to 20,000 FC
  • датчик: 180° Rotating Sensor
  • Додаткові вимірювання: Температура навколишнього середовища, вологість
  • Дисплей: 2.25-дюймовий РК-дисплей з підсвічуванням
  • функції: MAX/MIN recording, Data Hold, Auto Power-Off

10. Гарантія та підтримка

TopTes products are designed for reliability and performance. For warranty information, technical support, or service inquiries, please refer to the contact information provided on the TopTes official website or your purchase documentation. Please have your model numbers (TS-501B, TS-710) and purchase date available when contacting support.

© 2024 TOPTES. All rights reserved.

Ask a question about this manual