RIGOL DS1054Z

RIGOL DS1054Z Digital Oscilloscope User Manual

Model: DS1054Z

1. Вступ

The RIGOL DS1054Z is a 4-channel digital oscilloscope offering a 50MHz bandwidth, 1GSa/s real-time sampling rate, and a 24Mpt record length. It incorporates RIGOL's innovative UltraVision technology to provide advanced display and analysis capabilities. This manual provides essential information for the proper setup, operation, and maintenance of your DS1054Z oscilloscope.

2. Ключові характеристики

  • 50 MHz bandwidth with 4 analog channels.
  • До 1 Гвиб/с у режимі реального часуampлінг -курс.
  • Standard 12 Mpts memory depth, upgradeable to 24 Mpts.
  • Innovative UltraVision technology for enhanced signal visibility.
  • Waveform capture rate up to 30,000 wfms/s.
  • 7-inch WVGA (800x480) display with multi-level intensity grading.
  • All-in-one signal debugging and emulation.
  • Accelerated analysis and debugging for I2C, RS232, and SPI designs.

3. Продукт закінчивсяview

Цей розділ надає візуальний та функціональний оглядview of the RIGOL DS1054Z Digital Oscilloscope.

RIGOL DS1054Z Digital Oscilloscope front view

Малюнок 1: Спереду view of the RIGOL DS1054Z Digital Oscilloscope, showing the display, control panel, and input channels.

RIGOL DS1054Z Digital Oscilloscope rear view

Малюнок 2: Задня частина view of the RIGOL DS1054Z Digital Oscilloscope, displaying power input, USB, LAN, and auxiliary output ports.

4. Налаштування

  1. Розпакування: Carefully remove the oscilloscope and all accessories from the packaging. Verify that all included components (power cord, USB cable, 4x 150MHz probes) are present.
  2. Підключення живлення: Connect the provided power cord to the AC input on the rear panel of the oscilloscope and then to a suitable AC power outlet (100 V~240 V).
  3. Увімкнення: Press the power button located on the front panel to turn on the device. The display will illuminate, and the system will initiate its startup sequence.
  4. Підключення зонда: Connect the 150MHz probes to the desired input channels (CH1-CH4) on the front panel. Ensure a secure connection.
  5. Initial Probe Compensation: Before taking measurements, it is recommended to perform probe compensation to ensure accurate readings. Refer to the detailed user guide for specific instructions on probe compensation.

5. Інструкція з експлуатації

This section covers basic operational procedures for the DS1054Z oscilloscope.

5.1 Базове отримання сигналів

  1. Підключення сигналу: Підключіть зонд до джерела сигналу, який ви хочете виміряти.
  2. Виберіть канал: Press the corresponding channel button (e.g., CH1) to enable the channel.
  3. Автоматичне налаштування: For a quick display of the waveform, press the АВТО button. The oscilloscope will automatically adjust vertical, horizontal, and trigger settings.
  4. Ручні налаштування: Use the vertical scale (V/div) and position knobs for each channel, and the horizontal scale (s/div) and position knobs to fine-tune the waveform display.

5.2 Функції тригерів

The DS1054Z offers various trigger types to stabilize and capture specific events.

  • Тригер на краю: Triggers on a rising or falling edge of a signal.
  • Pulse Width Trigger: Спрацьовує за імпульсами заданої ширини.
  • Тригер нахилу: Запускається за сигналами з певним часом наростання або спаду.
  • Відеотригер: Спрацьовує за стандартними відеосигналами.
  • Pattern Trigger: Triggers when a specific logic pattern is met across multiple channels.
  • Duration Trigger: Triggers on events lasting a specified duration.

To access trigger settings, press the МЕНЮ ТРИГЕРА button and use the soft keys and multi-function knob to configure the desired trigger type and parameters.

Oscilloscope screen showing expanded functions and trigger settings

Figure 3: Oscilloscope display illustrating various expanded functions and trigger options, including memory depth settings.

5.3 Waveform Record and Playback

The DS1054Z allows for recording and playback of waveforms, which is useful for capturing transient events or analyzing long signal sequences.

  1. Access Record Function: Navigate to the waveform record menu (refer to the full user manual for exact menu path).
  2. Configure Recording: Set the desired record length and other parameters.
  3. Почати/зупинити запис: Initiate recording to capture waveforms. Stop recording when the desired data is acquired.
  4. Відтворення: Використовуйте елементи керування відтворенням, щоб повторитиview the recorded waveforms.
Oscilloscope screen showing waveform record and playback interface

Figure 4: Oscilloscope display showing the interface for waveform recording and playback, including controls for starting, stopping, and reviewing captured data.

6. Технічні характеристики

ПараметрСпецифікація
Аналогова пропускна здатність50 МГц
Канали4 аналогових каналів
Max. Real-time Sample Rate1 GSa/s (1 channel), 500 MSa/s (2 channels), 250 MSa/s (3/4 channels)
Максимальна глибина пам'яті12 Mpts (1 channel), 6 Mpts (2 channels), 3 Mpts (3/4 channels); upgradeable
Max. Waveform Capture Rate30,000 XNUMX wfms/s
Vertical Input Impedance1 МОм ±2%
Vertical Input Rangeвід 1 мВ/поділ до 10 В/поділ
Horizontal Time Base Range5 ns/div to 50 s/div
Standard Trigger FunctionsEdge, Pulse Width, Slope, Video, Pattern, Duration
Standard Bus DecodeParallel Bus
ІнтерфейсиUSB Host & Device, LAN (LXI), AUX Output (Trigger Out, Pass/Fail)
Дисплей7.0-inch WVGA (800x480) TFT LCD, 64 intensity grading levels
Джерело живленняAC: 100 V~240 V
Розміри (ШxВxГ)313.1 мм x 160.8 мм x 122.4 мм
вагаприбл. 3.2 кг
Аксесуари в комплектіPower cord, USB cable, 4x 150MHz probes

7. Технічне обслуговування

  • Прибирання: Регулярно очищуйте зовнішню частину осцилографа м’якою сухою тканиною. Для стійкого бруду використовуйте тканину, злегка протертуampened with water or a mild, non-abrasive cleaner. Avoid using harsh chemicals or solvents.
  • Вентиляція: Ensure that the ventilation openings on the device are not obstructed to prevent overheating.
  • Зберігання: When not in use for extended periods, store the oscilloscope in a clean, dry environment, away from direct sunlight and extreme temperatures.
  • Догляд за зондом: Handle probes carefully. Avoid bending or stressing the cables excessively. Store probes properly to prevent damage to the tips and connectors.

8. Вирішення проблем

This section addresses common issues you might encounter with your oscilloscope.

8.1 Немає дисплея після ввімкнення

  • Перевірте, чи шнур живлення надійно підключений як до осцилографа, так і до розетки.
  • Перевірте, чи справна розетка.
  • Переконайтеся, що кнопка живлення повністю натиснута.

8.2 Нестабільна форма хвилі

  • Adjust the trigger level to a stable point on the waveform.
  • Select an appropriate trigger type for the signal being measured (e.g., Edge trigger for periodic signals).
  • Check the probe connection and ensure it is properly compensated.
  • Verify the input signal's amplitude and frequency are within the oscilloscope's specifications.

8.3 Сигнал не відображається

  • Ensure the input channel is enabled (its corresponding button is lit).
  • Check the probe connection to the signal source and the oscilloscope.
  • Adjust the vertical scale (V/div) to a more sensitive setting.
  • Натисніть АВТО button to allow the oscilloscope to automatically find the signal.

9. Гарантія та підтримка

9.1 Інформація про гарантію

The RIGOL DS1054Z main unit comes with a standard Гарантія 3 рік from the date of purchase when bought through Amazon. Accessories such as modules, probes, and batteries are covered by a Гарантія 1 рік. This warranty covers operational defects confirmed by RIGOL Japan. Parallel import products are not eligible for warranty or free support from RIGOL Japan.

In case of a suspected malfunction, after our company confirms that the event is a malfunction, we will provide a replacement with the same product or repair service, or other appropriate response as determined by our company.

9.2 Initial Defect Exchange Policy

Returns are accepted within 14 days of product arrival for initial defects. Return shipping costs for reasons other than operational defects are borne by the purchaser. Questions regarding operational defects or usage are accepted via Amazon email.

9.3 Ремонт і калібрування

For repair or calibration services, please contact a domestic authorized RIGOL dealer.

9.4 Додаткові ресурси та підтримка

User guides, datasheets, and software for the DS1054Z can be downloaded from the official RIGOL Japan website. If you require an instruction manual earlier, please contact us via Amazon message.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.