Belden 2413 Category 6 Cable User Manual

Enhanced Category 6 Nonbonded-Pair Cable (1000FT, Grey)

Продукт закінченийview

The Belden 2413 is a high-performance 23 AWG (American Wire Gauge) 4-pair U/UTP (Unshielded/Unscreened Twisted Pair) cable designed for enhanced Category 6 applications. This CMP (Plenum) rated cable is supplied in a 1000-foot reel-in-box for convenient deployment. It is engineered to support high-speed data transmission in various network environments.

Diagram showing the internal structure of a network cable with four twisted pairs of wires.

Figure 1: Internal structure of the Belden 2413 cable, illustrating the four twisted pairs of copper conductors.

This nonbonded-pair cable is suitable for installations requiring plenum-rated materials, ensuring compliance with fire safety regulations in air-handling spaces. Its grey jacket provides a neutral aesthetic for various installation settings.

Налаштування та встановлення

Proper installation is crucial for optimal performance of the Belden 2413 cable. Follow these guidelines for a successful setup:

  1. Планування: Before installation, plan your cable runs, considering cable length requirements, pathway availability, and potential sources of electromagnetic interference (EMI). Ensure compliance with local building codes and standards.
  2. Обробка: Handle the cable carefully to avoid kinks, sharp bends, or excessive pulling tension, which can damage the internal conductors and degrade performance. The minimum bend radius for Category 6 cable should be observed (typically 4 times the cable diameter during installation, 8 times during operation).
  3. Витягування: When pulling cable from the reel-in-box, ensure a smooth, consistent pull. Use appropriate pulling lubricants if necessary, especially for long runs or conduits. Do not exceed the maximum pulling tension specified for Category 6 cables.
  4. Припинення: Terminate the cable using Category 6 compliant connectors (RJ45 jacks, patch panels) following T568A or T568B wiring standards. Ensure proper untwisting of pairs at the termination point is minimized to maintain performance.
  5. Заземлення (якщо застосовується): While U/UTP cables are unshielded, ensure all connected equipment and patch panels are properly grounded according to electrical codes.
  6. Маркування: Label both ends of each cable run clearly for easy identification and future troubleshooting.

Note: Always consult professional installation guides and local regulations for specific requirements.

Принципи роботи

The Belden 2413 cable is a passive component in a network infrastructure. Its "operation" involves reliably transmitting data signals between connected devices. Once properly installed and terminated, the cable facilitates communication by providing a low-loss, low-crosstalk pathway for electrical signals.

  • Передача даних: Supports data rates up to 10 Gigabit Ethernet over shorter distances (up to 55 meters) and 1 Gigabit Ethernet over longer distances (up to 100 meters), as per Category 6 standards.
  • Живлення через Ethernet (PoE): Compatible with various PoE standards (e.g., PoE, PoE+, UPoE) for delivering power to network devices over the same cable.
  • Цілісність сигналу: The twisted-pair design minimizes electromagnetic interference (EMI) and crosstalk, ensuring signal integrity and reliable data transfer.

No user interaction is required for the cable's operation once installed. Its performance is dependent on the quality of installation and the connected active network equipment.

Технічне обслуговування

Category 6 cables like the Belden 2413 are generally low-maintenance. However, periodic checks and proper environmental conditions can extend their lifespan and ensure continued performance:

  • Фізичний огляд: Periodically inspect exposed cable runs for any signs of physical damage, such as cuts, abrasions, or excessive bending. Address any damage promptly.
  • Екологічний контроль: Ensure the cable is not exposed to extreme temperatures, excessive humidity, or direct sunlight, which can degrade the jacket and insulation over time.
  • Пил і сміття: Keep termination points (jacks, patch panels) clean and free of dust and debris, which can interfere with connectivity. Use compressed air or lint-free wipes if necessary.
  • Управління кабелем: Maintain proper cable management to prevent tangles, strain on connectors, and accidental disconnections. Use cable ties or Velcro straps where appropriate.
  • Уникайте стресу: Do not hang heavy objects from cables or place excessive weight on them.

Усунення несправностей

If you experience network connectivity issues, consider the following troubleshooting steps related to the cabling:

  • Немає підключення:
    • Verify that both ends of the cable are securely plugged into the network devices (e.g., computer, switch, router).
    • Check the link lights on the network devices. If they are off, there might be a cable fault or a device issue.
    • Test the cable with a known working device or replace it with a known good cable to isolate the problem.
    • Inspect the RJ45 connectors for bent pins or improper termination.
  • Slow Network Speed/Intermittent Connection:
    • Ensure the cable length does not exceed the maximum recommended distance for Category 6 (100 meters for Gigabit Ethernet).
    • Check for excessive bends, kinks, or damage along the cable run.
    • Verify that the cable is not running parallel to or too close to sources of strong electromagnetic interference (e.g., power lines, fluorescent lights, motors).
    • Confirm that all network devices (NICs, switches, routers) are operating at the correct speed and duplex settings.
    • Consider using a cable certifier to test the cable's performance against Category 6 standards if issues persist.
  • Crosstalk/Noise:
    • Ensure proper termination techniques were used, minimizing untwisting of pairs.
    • Verify that all components (jacks, patch panels, patch cords) are Category 6 compliant.

If these steps do not resolve the issue, consult a qualified network technician.

Технічні характеристики

АтрибутЗначення
БрендБелден
Модель2413
Тип кабелюEnhanced Category 6 U/UTP Nonbonded-Pair
Калібр23 AWG
Кількість пар4 пара
Jacket RatingCMP (Пленум)
Довжина1000 FT (Reel-in-Box)
КолірСірий
Матеріал провідникаМідь
томtage Рейтинг300 вольт
ВиробникНассау
ASINB073Y9G8VT

Гарантія та підтримка

Information regarding the specific warranty terms for the Belden 2413 cable is not available in the provided product data. For detailed warranty information, please refer to the official Belden website or contact Belden customer support directly.

For technical support or further inquiries, please contact the manufacturer or your authorized Belden distributor.

© 2024 Belden Inc. All rights reserved. This manual is for informational purposes only.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.