Apex Apex460B

Apex Apex460B Large Diaphragm Multi-Pattern Tube Studio Condenser Microphone User Manual

Model: Apex460B

1. Вступ

The Apex Apex460B is a large diaphragm multi-pattern tube studio condenser microphone designed for professional audio recording. It offers versatile polar patterns including omnidirectional, cardioid, and figure-8, making it suitable for a wide range of recording applications from vocals to instruments. This manual provides essential information for the proper setup, operation, and maintenance of your Apex460B microphone.

2. Інформація про безпеку

УВАГА: РИЗИК УРАЖЕННЯ ЕЛЕКТРИЧНИМ СТРУМОМ. НЕ ВІДКРИВАТИ.

УВАГА: ЩОБ ЗМЕНШИТИ РИЗИК ПОЖЕЖІ АБО УРАЖЕННЯ ЕЛЕКТРИЧНИМ СТРУМОМ, НЕ ПІДДАЙТЕ ЦЕЙ ПРИСТРІЙ ДІЇ ДОЩУ АБО ВОЛОГИ.

  • Always ensure the power supply is disconnected from the mains before making any connections or disconnections.
  • Do not operate the microphone or power supply if they appear damaged.
  • Keep the unit away from water or excessive humidity.
  • Only use the power supply unit provided with the microphone.
  • Звертайтеся до кваліфікованого сервісного персоналу.

3. Налаштування

3.1 Розпакування

Обережно вийміть усі компоненти з упаковки. Переконайтеся, що є такі предмети:

  • Apex460B Condenser Microphone
  • Dedicated Power Supply Unit
  • Multi-pin Cable (for connecting microphone to power supply)
  • Амортизуюча кліпса
  • Кабель живлення

3.2 Connecting the Power Supply Unit

The Apex460B requires its dedicated power supply unit for operation. Follow these steps to connect it:

  1. Ensure the power supply unit is turned off and disconnected from the mains power.
  2. Connect the multi-pin cable from the Apex460B microphone to the ВХІД port on the power supply unit. Ensure the connection is secure.
  3. Connect a standard XLR cable (not included) from the ВИХІД port on the power supply unit to your audio interface, mixer, or preampліфірник.
  4. Connect the provided power cable to the power supply unit and then to a suitable AC power outlet.
Apex Apex460B Multi-pattern tube condenser microphone power supply unit with input, output, and polar pattern knob.

Figure 1: Apex Apex460B Power Supply Unit. This image shows the power supply unit for the Apex Apex460B microphone. It features an XLR output, a multi-pin input for the microphone, and a rotary knob for selecting polar patterns, ranging from omnidirectional to figure-8.

3.3 Монтаж мікрофона

Attach the Apex460B microphone to the included shock mount clip. The shock mount helps to isolate the microphone from vibrations and handling noise. Secure the shock mount to a sturdy microphone stand (not included).

4. Інструкція з експлуатації

4.1 Увімкнення

Once all connections are made, switch on the power supply unit. Allow the microphone approximately 10-15 minutes to warm up for optimal performance, as it is a tube microphone.

4.2 Selecting Polar Patterns

The Apex460B features multiple polar patterns, selectable via the rotary knob on the power supply unit. Each pattern offers distinct directional characteristics:

  • Всенаправлення: Captures sound equally from all directions. Ideal for room ambiance, group vocals, or instruments where a natural, open sound is desired.
  • Кардіоїд: Most sensitive to sound from the front, with significant rejection from the rear. Best for isolating a single sound source, such as a lead vocal or individual instrument, and minimizing room reflections or bleed from other sources.
  • Рисунок 8: Captures sound equally from the front and rear, with strong rejection from the sides. Useful for recording two vocalists facing each other, or for capturing the direct sound of an instrument along with room reflections from the rear.
  • Intermediate Patterns: The knob allows for selection of patterns between the main three, offering fine-tuning for specific recording scenarios.

Обертайте ПОЛЯРНИЙ ШАБЛОН knob on the power supply unit to select the desired pattern. It is recommended to experiment with different patterns to find the best sound for your specific recording environment and source.

4.3 Basic Recording Tips

  • Position the microphone appropriately for the sound source and chosen polar pattern.
  • Use a pop filter (not included) for vocal recordings to reduce plosive sounds.
  • Monitor your input levels carefully to avoid clipping and ensure a clean recording.
  • Experiment with microphone placement and room acoustics to achieve desired tonal characteristics.

5. Технічне обслуговування

5.1 Очищення

Wipe the microphone body and power supply unit with a soft, dry cloth. Do not use liquid cleaners or solvents, as these can damage the finish or internal components. Avoid touching the microphone capsule directly.

5.2 Заміна трубки

The Apex460B uses a vacuum tube which may require replacement over time. Tube replacement should only be performed by qualified technicians due to high internal voltages. If you experience a significant change in sound quality or a loss of signal, consult a professional audio service center. УВАГА: Високий об'ємtages are present inside the power supply and microphone. Do not attempt to open or service these units yourself.

5.3 Зберігання

When not in use, store the microphone in its protective case (if provided) or a clean, dry environment to protect it from dust, moisture, and physical damage.

6. Вирішення проблем

проблемаМожлива причинаРішення
Немає звуку
  • Блок живлення не підключено або не увімкнено.
  • Cables incorrectly connected or faulty.
  • Audio interface/mixer input not selected or gain too low.
  • Перевірте підключення живлення та вимикач.
  • Verify multi-pin and XLR cable connections. Test with different cables if possible.
  • Ensure correct input is selected and gain is adjusted on your audio device.
Низький або спотворений звук
  • Неправильне підсиленняtagінж.
  • Несправна трубка.
  • Microphone too far from source or polar pattern unsuitable.
  • Adjust gain on your audio interface/mixer.
  • Зверніться до кваліфікованого техніка для перевірки/заміни трубки.
  • Adjust microphone position or select a different polar pattern.
Excessive noise/hum
  • Проблема із заземлювальним контуром.
  • Перешкоди від інших електронних пристроїв.
  • Несправний кабель.
  • Переконайтеся, що все обладнання підключено до одного кола живлення, або використовуйте ізолятор заземлення.
  • Move microphone and cables away from power sources, monitors, or other electronics.
  • Перевірте з іншим кабелем XLR.

7. Технічні характеристики

  • модель: Apex460B (SYS6043)
  • Тип мікрофона: Large Diaphragm Multi-Pattern Tube Condenser
  • Полярні візерунки: Omnidirectional, Cardioid, Figure-8 (continuously variable)
  • Підключення: XLR (Output from Power Supply)
  • Чутливість звуку: 34 децибели
  • Коефіцієнт сигнал-шум: 76 дБ
  • Джерело живлення: Corded Electric (via dedicated power supply)
  • Матеріал корпусу: Metal, Film
  • Рекомендоване використання: Voice Recording, Video Recording
  • Включені компоненти: Microphone, Power Supply, Multi-pin Cable, Shock Mount Clip, Power Cable
  • Розміри предмета: 8 x 18 x 24 inches (Packaging/Overall product dimensions, specific mic dimensions not provided)

8. Інформація про гарантію

Apex products are designed and manufactured to the highest quality standards. This product is covered by a limited warranty against defects in materials and workmanship. The specific terms and duration of the warranty may vary by region and retailer. Please retain your proof of purchase for warranty claims. For detailed warranty information, please refer to the warranty card included with your product or contact your local Apex distributor.

9. Підтримка клієнтів

If you have any questions, require technical assistance, or need to report a problem with your Apex460B microphone, please contact Apex customer support or your authorized dealer. Please have your product model number (Apex460B or SYS6043) and proof of purchase ready when contacting support.

For the most up-to-date support information, visit the official Apex webсайт.

© 2024 Apex. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.